Joseph Doherty 2fc327a8d5 [F55 Path A] DCOM-managed INmxSvcCallback sink
Replace the hand-rolled CallbackExporter (TCP listener + custom
OBJREF) with a real `windows-rs` `#[implement]` COM class for
INmxSvcCallback, marshalled via CoMarshalInterface. NmxSvc validates
the callback OBJREF by calling IObjectExporter::ResolveOxid against
the local RPCSS at 127.0.0.1:135; hand-rolled OXIDs aren't registered
there, which is why RegisterEngine2 returned RPC_S_SERVER_UNAVAILABLE
(1722) on every live attempt. CoMarshalInterface registers the OXID
with RPCSS automatically, so the SCM-side resolution succeeds.

Mirrors MxNativeSession.CreateRegisteredService (cs:624), which is
the .NET reference's working path:
  ComObjRefProvider.MarshalInterfaceObjRef(callback,
    INmxSvcCallback, DifferentMachine)

Layout:
- mxaccess-callback::dcom_sink — INmxSvcCallback + DcomCallbackSink
  + create_dcom_callback_sink_objref. Forwards inbound calls into
  the same CallbackEvent::CallbackInvoked { opnum, body } shape the
  legacy exporter produces, so callback_router stays path-agnostic.
- Session::from_nmx_client — branched on `windows-com`. Real DCOM
  sink when on; legacy CallbackExporter when off (kept for unit
  tests that run against an in-process fake NMX peer).
- SessionInner.dcom_sink_holder: Option<IUnknownHolder> — keeps the
  COM ref alive for the session's lifetime; shutdown_nmx drops it.
- mxaccess-rpc + mxaccess-callback: windows-rs 0.59 → 0.62. The 0.59
  #[implement] macro generates code that doesn't compile under
  edition 2024; 0.62 is fixed.

Live result: cargo test -p mxaccess-compat --features
live-windows-com --test lmx_write_complete_live -- --ignored
--nocapture passes end-to-end. RegisterEngine2 OK, write
round-trips, OnWriteComplete fires with the captured MxStatus shape.

Unblocks F49 step 5; F55 marked Resolved in design/followups.md.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-06 09:25:44 -04:00
..