Promotes the previously hardcoded transport-layer settings to ModbusDriverOptions so users can tune them through DriverConfig JSON without recompiling. Three new option groups: 1. KeepAlive (ModbusKeepAliveOptions): Enabled / Time / Interval / RetryCount. Defaults preserve the historical PR 53 wire output exactly (Enabled=true, Time=30s, Interval=10s, RetryCount=3). Set Enabled=false for PLCs that reject SO_KEEPALIVE. 2. IdleDisconnectTimeout (TimeSpan?): when set, the transport tracks last-PDU- success and proactively closes + reconnects on the next request after the threshold. Defends against silent NAT / firewall socket reaping. Default null = disabled (no behaviour change). 3. Reconnect (ModbusReconnectOptions): InitialDelay / MaxDelay / BackoffMultiplier for the post-drop reconnect loop. Defaults (InitialDelay=0, MaxDelay=30s, Multiplier=2.0) preserve the historical immediate-retry behaviour for the first attempt and add geometric backoff only if the reconnect itself fails. Capped at 10 attempts before propagating. ModbusTcpTransport ctor extended with optional keepAlive / idleDisconnect / reconnect parameters; existing 4-arg call sites continue to compile. Factory DTO gains parallel KeepAlive / IdleDisconnectMs / Reconnect fields with default-aware binding. 5 new ModbusConnectionOptionsTests covering the default-preservation contract (every default field matches pre-#139) and the JSON-binding round-trip for each knob group. Existing 204 unit tests still green.