T13b: the isolated otopcua-t13b pair with OpcUa:Redundancy:Mode absent, on origin/masterf826af8e(it containsc569f806) and A/B on c569f806^ (687256d6). Every check passes on both builds: - levels 250/240; - Good data on both nodes; - writes, Acknowledge, AddComment and alarm delivery on the Secondary; - graceful stop: the survivor reaches 250 259 ms after Leaving (pre-fix 270 ms); - crash: 250 at +43.6 s (pre-fix +42.8 s), with no demotion at auto-down; - rejoin at 240 with no failback. The role-decision changes are gated on IsWarm and do not run under Unset. Plan L5, the design's section 4.3 and the Warm table in Redundancy.md now say a Leaving/Exiting node reports ServiceLevel 0, not 90 (ComputeWarm returns 0 for any member that is not Up/Joining; T13 note A). Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
374 lines
26 KiB
Markdown
374 lines
26 KiB
Markdown
# Warm non-transparent redundancy (Gitea #717): implementation plan
|
||
|
||
Status: **APPROVED by the owner 2026-11-13** (#717), together with `2026-11-11-warm-redundancy-717-design.md`
|
||
(referred to below as "the spec", with § references). The spec's §9 records the owner's answers: writes and Part 9
|
||
methods are refused `BadInvalidState` under Warm, promote-while-unreachable is on by default, the standby status is
|
||
`BadOutOfService`, there is no ConfigDb migration, and the bands are as drafted.
|
||
Every task ships **dark**: `OpcUa:Redundancy:Mode` defaults to `Unset`, so merging any task changes no deployed
|
||
behaviour.
|
||
|
||
Conventions:
|
||
|
||
- **Wire tests** use a real OPC Foundation client session against a loopback `OtOpcUaSdkServer`, in
|
||
`tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests` (the home of `DualEndpointTests`,
|
||
`ConditionRefreshDeferralWireTests` and `FolderConditionRefreshWireTests`).
|
||
- **Actor tests** go in `tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests` and
|
||
`tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests`.
|
||
- Every gate gets an **allow** leg as well as a deny leg (the vacuous-test rule), and a mutation check: revert the
|
||
production line and confirm the test fails.
|
||
|
||
## T0: SDK 2.0.1 re-proof spikes (throwaway, separately approved)
|
||
|
||
The 1.5.378.106 spikes do not carry over (spec §10). Write throwaway loopback fixtures against **2.0.1**, outside
|
||
`src/`. No product edits. Each fixture is rerun independently and its evidence is recorded in
|
||
`docs/plans/evidence/2026-11-xx-717-sdk2/`.
|
||
|
||
- **a. Metadata graph.** Build it via `CreateMainNodeManagerFactory` + `AddBehaviourToPredefinedNodeAsync`. Check
|
||
Read/Browse/Translate of `i=2296` (HasTypeDefinition 2039), `i=3709`, and `i=11314` for both Warm and None. The
|
||
passive `i=11314` visit must resolve to the constructed instance.
|
||
- **b. Read projection coverage.** Cover Read, the initial sample on create, the change fan-out after
|
||
`ClearChangeMasks`, ResendData, queue size 1 vs. N, an AggregateFilter item, and Sampling → Reporting. Decide
|
||
between `OnSimpleReadValue` and a `ReadValueAttribute` override, and record which async callback paths 2.0.1
|
||
takes.
|
||
- **c. Provenance.** Stamp items through the 2.0.1 `MonitoredItemFactory` / `MonitoredItemCreateDecision`. Exercise
|
||
ModifyMonitoredItems handle change, delete/reuse, TransferSubscriptions (`IMonitoredItemTransferCoordinator`),
|
||
and a restore.
|
||
- **d. Publish/Republish.** Override `PublishAsync`/`RepublishAsync` with the 2.0.1 signatures (`RequestLifetime`).
|
||
Cover the first-delivery choice, first delivery through Republish, an ack followed by `BadMessageNotAvailable`,
|
||
and a cancelled or failed response.
|
||
- **e. Events.** Exercise the stamp/deliver split under the #855 per-item folder path and the #854 Server-object
|
||
cut. Run the promotion refresh on all three item kinds, and a client ConditionRefresh/2 while Standby.
|
||
|
||
**Exit:** a short results note per fixture, and an owner go/no-go. A "no" on (c) or (d) re-opens D4's mechanism.
|
||
D4 itself stays an owner decision.
|
||
|
||
**T0 run 2026-11-13: (a) and (b) pass; (c) and (d) are no-go as written.** SDK 2.0.1 hands every Publish and Republish
|
||
a fresh clone of the cached message and pools the notification payloads, so provenance and the first-delivery choice
|
||
cannot be keyed by object. An alternative, keyed by `(SubscriptionId, SequenceNumber)` with a clone-surviving
|
||
provenance token, passed the same spike. **The owner adopted it on 2026-11-13**; spec §4.6 and T2/T7 below describe
|
||
it. Evidence: `docs/plans/evidence/2026-11-13-717-sdk2/RESULTS.md`.
|
||
|
||
## T1: Configuration, validation, effective self URI
|
||
|
||
**Files:**
|
||
- `src/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer/OpcUaApplicationHost.cs`: options at `:29-121`. Add
|
||
`OpcUaRedundancyOptions Redundancy` (`Mode`; `PromoteWhilePrimaryUnreachable`, default `true`, owner answer Q2).
|
||
- `src/Server/ZB.MOM.WW.OtOpcUa.Host/Configuration/OpcUaApplicationHostOptionsValidator.cs`.
|
||
- A post-load check in `StartAsync` (`:218-250`) against the effective `ApplicationConfiguration.ApplicationUri`.
|
||
|
||
**Rules (spec §3):**
|
||
- `Hot` and unknown values fail host start.
|
||
- `Warm` requires at least one peer, all URIs distinct, self not listed as a peer, and the `driver` role.
|
||
- `None` requires no peers.
|
||
|
||
**Tests:**
|
||
- A validator matrix.
|
||
- An XML `ApplicationConfigPath` whose URI differs from the options value, proving the effective URI is used.
|
||
- A boot-banner log assertion.
|
||
|
||
## T2: Standard redundancy metadata graph
|
||
|
||
**Files:**
|
||
- `src/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer/OtOpcUaSdkServer.cs`: in the existing `OnNodeManagerStartedAsync`
|
||
override, install the T0a graph per mode through `IPredefinedNodeSubtypeReplacer.ReplacePredefinedInstanceSubtypeAsync`
|
||
(no `CreateMainNodeManagerFactory` override is needed on 2.0.1).
|
||
- Under `Warm`, the initial `Server.ServiceLevel` is set to **1** in the same pass (spec §4.3). `Unset` must not
|
||
touch the graph. Under `None` the SDK's orphan `i=11314` (T0a finding) is deleted so it is absent by NodeId too.
|
||
|
||
**Tests (wire):**
|
||
- Per mode, check the `i=3709` value, the `i=2296` type definition, the presence or absence of `i=11314`, its
|
||
value order `[effectiveSelf, peers…]`, and that it is read-only (a Write returns `BadNotWritable`).
|
||
- `ServerArray` (`i=2254`) is unchanged; extend `DualEndpointTests`.
|
||
- A Warm server's ServiceLevel reads 1 before the first publish.
|
||
- Security profiles and startup are unaffected under `Unset` (golden read of today's values).
|
||
|
||
## T3: Ordered redundancy snapshots (spec §4.2)
|
||
|
||
**Files:**
|
||
- `src/Core/ZB.MOM.WW.OtOpcUa.Commons/Messages/Redundancy/RedundancyStateChanged.cs` (`:9-11`): add an optional
|
||
`SnapshotRevision? Revision` (additive).
|
||
- `RedundancyStateActor.cs`:
|
||
- stamp the revision in `PublishIfDirty` (`:105-113`);
|
||
- set `IncarnationTick` in `PreStart`;
|
||
- read the host's `UpNumber` from `Cluster.SelfMember`.
|
||
- Subscribers: accept only a newer revision in `OpcUaPublishActor.HandleRedundancyStateChanged` (`:1494-1498`) and
|
||
`DriverHostActor.OnRedundancyStateChanged` (`:2555`).
|
||
- An unrevisioned snapshot keeps today's handling for the existing gates.
|
||
|
||
**Tests:**
|
||
- Ordering unit tests: an older singleton incarnation's heartbeat after a newer snapshot is dropped; a same-process
|
||
singleton restart advances.
|
||
- A **real 2-node cluster** handover test (pattern: `RedundancyPrimaryElectionTests`). It holds back the old
|
||
incarnation's last publish through the `_broadcastOverride` seam (`:111`) and asserts the subscriber keeps the
|
||
new Primary.
|
||
- Serialization round-trip of the extended message, plus a mixed-version decode with the field absent.
|
||
- The pinned assumption: a removed node cannot rejoin without a new `ActorSystem`.
|
||
|
||
## T4: Warm role verdict and ServiceLevel bands (spec §4.1, §4.3)
|
||
|
||
**Files:**
|
||
- New `src/Server/ZB.MOM.WW.OtOpcUa.Runtime/Redundancy/WarmRoleAuthority.cs`: a pure function of membership view,
|
||
accepted snapshot, `EndpointListening` and `SelfMember` status.
|
||
- `src/Core/ZB.MOM.WW.OtOpcUa.Cluster/Redundancy/ServiceLevelCalculator.cs`: add `ComputeWarm(inputs, isActive)`.
|
||
`Compute` itself is unchanged.
|
||
- `OpcUaPublishActor.RecomputeServiceLevel` (`:1576-1636`) branches on mode. It subscribes to `MemberUp/Removed`
|
||
and to reachability (owner answer Q2) so the verdict re-derives on membership changes, not only on snapshots.
|
||
|
||
**Tests:**
|
||
- A truth table covering every row of §4.3 and the invariant *max(Standby) < min(Active serving)*.
|
||
- Membership/snapshot disagreement gives Standby, plus the 20 s Warning.
|
||
- Boot with an unknown role gives Standby; a lone node goes Active after its own snapshot.
|
||
- `None`/`Unset` produce byte-identical output to today's `ServiceLevelCalculatorTests`.
|
||
- DB-less mode (#721 timer) is covered.
|
||
|
||
## T5: Standby projection seam and transition sequencer (spec §4.7)
|
||
|
||
**Files:**
|
||
- New `src/Core/ZB.MOM.WW.OtOpcUa.Commons/OpcUa/IStandbyProjection.cs`, with a deferred/late-bound adapter that
|
||
mirrors `DeferredServiceLevelPublisher` and retains the latest state across binding (the #719 lesson).
|
||
- Bound in `src/Server/ZB.MOM.WW.OtOpcUa.Host/OpcUa/OtOpcUaServerHostedService.cs` next to the ServiceLevel binding.
|
||
- `OpcUaPublishActor` runs promotion and demotion as one serialized handler, in the §4.7 step order.
|
||
|
||
**Tests (actor, with a recording fake):**
|
||
- The exact step order for both directions.
|
||
- A ServiceLevel publish failure halts a promotion before the Active level and retries; a demotion continues.
|
||
- A burst of alternating verdicts converges on the last one.
|
||
- Binding after the first transition replays the current state.
|
||
|
||
## T6: Per-tag read projection (spec §4.4)
|
||
|
||
**Files:**
|
||
- `src/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer/EquipmentVariableState.cs`: the hook decided in T0b, reading a
|
||
node-manager-wide volatile projection flag. Stored `Value` is never modified.
|
||
- `OtOpcUaNodeManager` implements `IStandbyProjection.SetDataProjection`.
|
||
- Owner answer Q1: under Warm, the ordinary-tag write handler refuses a write on the Standby with `BadInvalidState`
|
||
before it reaches the node-write gateway. `Unset`/`None` keep the #5 optimistic path.
|
||
|
||
**Tests (wire):**
|
||
- Warm Standby: a Write returns `BadInvalidState` and the gateway is never called; on the Active node the same Write
|
||
reaches the gateway; under `Unset` a node that is not Primary still takes today's optimistic path.
|
||
- Standby Read of a raw tag, a UNS reference, a virtual tag and a Calculation tag returns `BadOutOfService`/null.
|
||
- A Standby Read of a condition child, `i=2267` or `i=3709` stays Good.
|
||
- A Read with an IndexRange on an array tag is projected; a DataEncoding request is projected.
|
||
- Acquisition continues: flip to Active and the latest value is read without any new driver publish.
|
||
- ACL on: a denied node is still `BadUserAccessDenied` and the projection never leaks existence.
|
||
|
||
## T7: Ordinary-tag marker and first-delivery decision record (spec §4.6, D4)
|
||
|
||
The T0-adopted alternative (owner, 2026-11-13). The 1.5 object-keyed provenance and choice table are not used.
|
||
|
||
**Files:**
|
||
- `OtOpcUaNodeManager`: replace `m_monitoredItemManager` with a `MonitoredNodeMonitoredItemManager` subclass that
|
||
re-implements `IMonitoredItemManager.CreateMonitoredItem` and creates a custom sampled item for ordinary-tag
|
||
(`EquipmentVariableState`) `Value` items only. Its `Publish` runs base first and then sets
|
||
`MonitoredItemNotification.Message` to an `OrdinaryTagMarker(ClientHandle, DataValue)`.
|
||
- `OtOpcUaSdkServer.cs`: `PublishAsync`/`RepublishAsync` overrides and a new `FirstDeliveryRecord` keyed by
|
||
`(SubscriptionId, SequenceNumber)`, pruned by `AvailableSequenceNumbers` and bounded.
|
||
- Wire into `OtOpcUaNodeManager.CreateMonitoredItems` / `OnMonitoredItemCreated` without disturbing ACL filtering
|
||
or `_liveItems`.
|
||
|
||
**Tests (wire):**
|
||
- Queued Good samples, a ClientHandle change, then demotion: the first Publish carries `BadOutOfService`, and a
|
||
Republish returns the same projected payload.
|
||
- Prebuilt sequences (`maxNotificationsPerPublish=1`), then demotion: the next Publish is projected, and Republish
|
||
returns the recorded projected choice. A Republish of a prebuilt, never-sent number is `BadMessageNotAvailable`.
|
||
- Good delivered while Active, then demotion: Republish returns the original Good; after an ack it is
|
||
`BadMessageNotAvailable`.
|
||
- A mixed subscription (ordinary tag + `i=2267` + condition-child item): only ordinary-tag items are rewritten.
|
||
- The marker is validated: a notification whose marker names another handle or value is not rewritten (unit).
|
||
- **SDK-field regression pin:** the helper survives `CoreUtils.Clone` and is not encoded by the binary encoder.
|
||
- The record is bounded, and pruned against `AvailableSequenceNumbers`.
|
||
- Concurrent Publish and role flip, by a stress loop with a deterministic barrier, not sleeps.
|
||
|
||
## T8: Promotion and demotion of live data items
|
||
|
||
**Files:**
|
||
- `OtOpcUaNodeManager`: `IStandbyProjection.QueueCurrentToLiveItems(bool projected)` iterates `_liveItems`. It
|
||
reuses the QueueValue-with-`ignoreFilters` pattern (`:7303`), **not** detach or `MonitoringMode.Disabled`; the
|
||
disabled-mode-drops-queue lesson applies. ACL-suppressed items are skipped.
|
||
|
||
**Tests (wire):**
|
||
- Demotion delivers exactly one `BadOutOfService` per item, then silence while values keep changing internally.
|
||
- Promotion delivers the current Good value without a driver publish.
|
||
- An ACL-stood-down item receives nothing either way.
|
||
- A DeadbandFilter item still receives the promotion value.
|
||
|
||
## T9: Alarm event suppression and promotion refresh (spec §4.5, D3, D5)
|
||
|
||
**Files (`OtOpcUaNodeManager`):**
|
||
- Split `ReportConditionEvent` (`:1376`) into stamp and deliver; deliver is gated by the projection flag.
|
||
- Audit all callers (`:1254`, `:1341`, `:2842`, `:4659`) and `WireMethodTransitionReporting`.
|
||
- `IStandbyProjection.RefreshAllEventItems()` runs the existing `ConditionRefresh` (`:6586`) Server-object path and
|
||
`RefreshDirectItems` (`:6974`) over every live event item, from `_allEventsItems` and `_eventItems`.
|
||
- `ReportToServerObject` (`:6060`) is untouched.
|
||
- Owner answer Q4: under Warm, every Part 9 condition method (native or scripted) is refused `BadInvalidState` on
|
||
the Standby before it changes condition state.
|
||
|
||
**Tests (wire, ACL off and on):**
|
||
- Warm Standby: Acknowledge and a shelving method on a scripted condition return `BadInvalidState` and route no
|
||
command; the Active node accepts them; `Unset` keeps today's scripted-method acceptance.
|
||
- A new alarm on the Standby reaches no Server-object, folder or direct item.
|
||
- Model-change and audit events are still delivered on the Standby.
|
||
- A client ConditionRefresh **and** ConditionRefresh2 on the Standby return Start, retained, End (D5).
|
||
- Promotion gives Start, retained, End on all three item kinds, followed by new events.
|
||
- An ACL-denied condition is absent from the promotion refresh.
|
||
- A condition raised and cleared (Retain=false) while Standby is not replayed.
|
||
- An event reported while Active but deferred (#838, via `NotifierStall`) is still delivered after demotion.
|
||
- A Standby-stamped EventId is accepted by Acknowledge after promotion.
|
||
- The `RingEventQueueFactory` path is untouched (`RingEventMonitoredItemQueueParityTests` stay green).
|
||
- Re-run `EventQueueOverflowAclWireTests` and `ConditionMethodEventTests`.
|
||
|
||
## T10: Deploy-time mode cross-check and observability (spec §3, §7)
|
||
|
||
**Files:**
|
||
- `src/Server/ZB.MOM.WW.OtOpcUa.Runtime/Drivers/DeploymentArtifact.cs`: read this node's cluster
|
||
`RedundancyMode` from the `Clusters` array.
|
||
- `OpcUaPublishActor` compares it with the local mode at apply.
|
||
- `src/Core/ZB.MOM.WW.OtOpcUa.Commons/Observability/OtOpcUaTelemetry.cs`: add the six instruments.
|
||
|
||
**Tests:**
|
||
- A mismatch logs an Error and records the metric.
|
||
- Each counter fires on its path. Use a `MeterListener` filtered by **instrument instance**, never by meter name
|
||
alone (the #503 lesson).
|
||
|
||
## T11: ScadaBridge prerequisite (cross-repo)
|
||
|
||
- **Filed as ScadaBridge#138** (2026-11-13). A ScadaBridge issue (`type:feature`, `cross-repo`, `priority:p1`, linked to #717). The DCL becomes
|
||
ServiceLevel-aware: monitor `i=2267`, and fail over when it is below 200 for a configurable window while the
|
||
other endpoint reports higher. Also add a test for an unsolicited RefreshStart/End on existing alarm items
|
||
(spec §5).
|
||
- File the lmxopcua companion as `blocked` + `cross-repo`.
|
||
- **The Warm flip in T13/rollout is gated on that issue being deployed.**
|
||
|
||
## T12: Documentation and index
|
||
|
||
- `docs/Redundancy.md`: rewrite the `:9` block, add a Warm contract section, update the tiers table. Remove the
|
||
generic "standby / no device contact / exactly-once" wording that contradicts acquisition and at-least-once
|
||
(c7794).
|
||
- `docs/OpcUaServer.md:70`, `docs/Configuration.md` (the new keys), and `docs/security.md` (ns=0 stays ungated;
|
||
projection order vs. ACL).
|
||
- `.claude/rules/cluster-topology.md` §Redundancy.
|
||
- `docs/plans/phase-6-3-redundancy-interop-plan.md` A2/A4/A5b: under Warm, A2 expects 90 and A4/A5b become
|
||
testable. Add `docs/v2/redundancy-interop-playbook.md`.
|
||
- Umbrella: update the OtOpcUa row and `sister-project-history/otopcua.md` in `../scadaproj` on **its `main`**,
|
||
pushed (root `CLAUDE.md` procedure).
|
||
|
||
## T13: Live gate on docker-dev (central pair, `:4840` / `:4841`)
|
||
|
||
**Overlay:** `docker-dev/docker-compose.warm.yml`, central-1/2 only. It sets `OpcUa__Redundancy__Mode=Warm`. The base
|
||
compose file already gives each central its own `OpcUa__ApplicationUri=urn:OtOpcUa:central-1|2` (matching
|
||
`seed-clusters.sql`) and its partner in `OpcUa__PeerApplicationUris__0` (lmxopcua#801, after spec §2 was written). Login is disabled on the rig, so drive
|
||
everything yourself. Use `otopcua-cli` from `src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI` against both ports.
|
||
|
||
| Leg | Procedure | Pass |
|
||
|---|---|---|
|
||
| L1 metadata | `redundancy` on :4840 and :4841 | `RedundancySupport=Warm`. ServerUriArray is self first and differs per node. Same URIs in both. |
|
||
| L2 bands | `read -n i=2267` on both | Primary 250, Standby 90 |
|
||
| L3 standby data | `read` and `subscribe` of a raw tag and its UNS reference on the Standby | `BadOutOfService`/null; the Primary shows Good at the same moment |
|
||
| L4 standby alarms | `alarms` on both. Trip a scripted alarm via its source tag. | Event on the Primary only. A ConditionRefresh on the Standby lists it as retained (D5). |
|
||
| L5 manual failover | AdminUI manual failover (`docs/Redundancy.md` §Manual failover). Keep the CLI subscriptions open on both. | Old Primary: SL drops to 0 (a Leaving/Exiting member is not Up/Joining, so `ServiceLevelCalculator.ComputeWarm` returns 0; T13 note A), then `BadOutOfService`, with no Good delivered after the drop. New Primary: Good values, then RefreshStart / retained / RefreshEnd, then SL 250, in that order (timestamps). |
|
||
| L6 crash | `docker kill central-<primary>` | The survivor goes Active once the Primary is unreachable (`PromoteWhilePrimaryUnreachable`, owner answer Q2). Record the measured gap. |
|
||
| L7 rejoin | Restart the killed node | It comes back Standby (90) and never shows 250 or 255. The boot read is 1 or 90. |
|
||
| L8 standalone | site-b-2 (or a one-node overlay) with `Mode=None` | `RedundancySupport=None`, no `i=11314`, data Good |
|
||
| L9 Unset control | Another node left on `Unset` | Byte-identical to pre-change: SL 240/250, SDK-default `i=3709` |
|
||
| L10 writes/history | Write and HistoryRead on the Standby | The write is refused `BadInvalidState` (owner answer Q1); HistoryRead is Good. |
|
||
| L11 transfer | A UserName session's subscription on the Standby is taken over by a second session of the same identity (TransferSubscriptions), then the node is demoted/promoted | The transferred items keep their marker; a demotion still projects; a promotion delivers Good. |
|
||
| L12 durable restore | A durable subscription, if the rig's SDK configuration enables them, across a node restart | The restored items are created through the custom item (projected on the Standby). If durable subscriptions are not enabled on the rig, record that and leave the leg open. |
|
||
|
||
Record evidence in `docs/plans/2026-11-xx-warm-redundancy-717-live-gate.md`. Do **not** mark G8/G9 (#615); they
|
||
need CTT and a production client (Ignition 8.3 / ScadaBridge after T11).
|
||
|
||
## Rollout
|
||
|
||
1. Merge T1–T12 dark (`Unset` default). The full CI floor applies.
|
||
2. Deploy the ScadaBridge T11 change everywhere ScadaBridge reads OtOpcUa.
|
||
3. Upgrade **both** nodes of a pair to a revision-capable build (T3) before flipping either one.
|
||
4. Flip both nodes of one docker-dev pair, then run T13. After that, flip one non-production site pair.
|
||
5. Production is a separate, owner-approved change per pair. Flip the **Secondary first**, then the Primary, in
|
||
one window.
|
||
|
||
A mixed window (one `Warm`, one `Unset`) is tolerable: the Unset node serves Good at 240/250. But do not leave it
|
||
that way, because `ServerUriArray` then exists on only one node.
|
||
|
||
## Rollback
|
||
|
||
Set `OpcUa:Redundancy:Mode=Unset` on both nodes and restart them. The setting is startup-static, so there is
|
||
nothing persistent to undo: no schema changes and no artifact changes. The `Revision` field stays and is harmless,
|
||
because unrevisioned handling is preserved. Rolling back ScadaBridge is independent; its ServiceLevel-aware
|
||
failover also works against `Unset` servers.
|
||
|
||
## Implementation status (2026-11-13)
|
||
|
||
T1–T10 and T12 are implemented on `master`, default-off (`OpcUa:Redundancy:Mode` defaults to `Unset`, pinned by
|
||
`WarmRedundancyWireTests.Unset_is_todays_server_exactly` and `OpcUaPublishActorWarmTests.Unset_never_drives_the_projection_and_keeps_todays_levels`).
|
||
T11 is ScadaBridge#138 (separate). **T13 ran 2026-11-13** on an isolated two-node pair (not the shared docker-dev rig):
|
||
every applicable leg passes after `c569f806`, which fixes two crash-failover defects the gate found. The survivor no
|
||
longer demotes when auto-down removes the Primary, and the verdict reads its own cluster events instead of the lagging
|
||
read view. Evidence: `docs/plans/evidence/2026-11-13-717-t13/RESULTS.md`. L8 (None) was not run, and L12 is not
|
||
applicable (durable subscriptions are off). G8/G9 (#615) stay open.
|
||
|
||
Test homes: `WarmStandbyUnitTests` (OpcUaServer.Tests: marker, rewrite, decision record, the SDK-field regression pin,
|
||
option rules), `WarmRedundancyWireTests` (OpcUaServer.IntegrationTests: metadata per mode, read projection, write and
|
||
Part 9 refusal, the three T0 demotion timings, live-item queue, alarm suppression/refresh, effective-URI XML load),
|
||
`WarmRedundancyRevisionTests` + `WarmServiceLevelBandTests` (ControlPlane.Tests), `WarmRoleAuthorityTests` +
|
||
`OpcUaPublishActorWarmTests` (Runtime.Tests), `OpcUaRedundancyValidationTests` (Host.IntegrationTests). The deferred
|
||
depth below adds `WarmSingletonHandoverTests` (ControlPlane.Tests), `WarmRedundancyMetricsTests` (Runtime.Tests),
|
||
`WarmStandbyCloneMatrixTests` (OpcUaServer.Tests), `WarmRedundancyWireTests.Deferred.cs` and `WarmRedundancyPooledWireTests`
|
||
(OpcUaServer.IntegrationTests).
|
||
|
||
**Deferred coverage added (2026-11-13, in-process, no docker).** Each test was mutation-checked against a deliberately
|
||
broken implementation and failed. No product bug was found.
|
||
|
||
- **T3:** `WarmSingletonHandoverTests` (ControlPlane.Tests). A real 2-node cluster runs the redundancy singleton under
|
||
`ClusterSingletonManager` on both nodes. The old incarnation's last publish is held back through the broadcast seam,
|
||
its node is downed, and the singleton hands over. The held publish is then delivered to a real Warm
|
||
`OpcUaPublishActor` on the survivor. That publish is the older revision but has the higher sequence. The survivor
|
||
stays Active. The second test pins that a removed node cannot rejoin from its old ActorSystem. A new ActorSystem on
|
||
the same address rejoins as a younger member, with a higher up-number. Mutations killed:
|
||
- the gate accepts older revisions;
|
||
- the revision drops the up-number and incarnation (sequence only);
|
||
- for the pin, skipping the Down (a harness negative control).
|
||
- **T6:** `A_DataEncoding_read_and_item_are_projected_…` (wire). On the Standby, a Binary or XML DataEncoding read of
|
||
a structured (EUInformation) tag is projected. An encoding a scalar cannot take still returns the base read's own
|
||
`BadDataEncodingUnsupported`. An item created with `DefaultXml` gets the projected value on the Standby, and on
|
||
promotion it receives the value read through its own encoding (TypeId `i=888`). Mutations killed:
|
||
- DataEncoding reads are not projected;
|
||
- the promotion queue ignores the item's DataEncoding.
|
||
- **T7:**
|
||
- `An_item_deleted_between_queue_and_publish_…` (wire). The deleted item's queued samples never surface. Its
|
||
sibling is still first-delivered projected, and a Republish gives the same result.
|
||
- `WarmRedundancyPooledWireTests.A_client_handle_reused_after_delete_…` (wire, non-parallel collection). A marked
|
||
payload goes back through SDK 2.0.1's process-wide payload pool, and its ClientHandle is reused by an `i=2267`
|
||
item. That item stays Good. The test first asserts that the pool really hands out a marked payload.
|
||
- `WarmStandbyCloneMatrixTests` (unit). One delivered clone carries two DataChangeNotifications (one with
|
||
DiagnosticInfos), an EventNotificationList and a StatusChangeNotification. Only marked values are rewritten.
|
||
Diagnostics, events and status pass through in order. Neither the clone nor the cached message is mutated, and
|
||
the result encodes. Two clones project to identical bytes. A recycled payload's stale marker, rented through the
|
||
real pool with the same handle, never validates.
|
||
- Mutations killed:
|
||
- the marker is not validated (wire and unit);
|
||
- the marker is not set;
|
||
- DiagnosticInfos are dropped;
|
||
- non-data payloads are dropped;
|
||
- the rewrite happens in place;
|
||
- only the first DataChangeNotification is rewritten.
|
||
- **T8:** `An_ACL_stood_down_item_receives_nothing_…` (wire). An item that `RevalidateMonitoredItems` stood down gets
|
||
nothing from a demotion or a promotion (`QueueCurrentToLiveItems` returns 1, not 2). Its permitted sibling gets
|
||
both. Once the grant is restored, the next demotion reaches the item. Mutation killed: stood-down items are not
|
||
skipped.
|
||
- **T10:**
|
||
- `WarmRedundancyMetricsTests` (Runtime.Tests, non-parallel collection) checks four things:
|
||
- `warm_transition`, with direction and reason (`agreed` / `snapshot`), and no count on a same-role snapshot;
|
||
- the `warm_role` gauge, -1, then 0, then 1, then 0;
|
||
- `snapshot_rejected` at the publish actor for `older_revision` and `unrevisioned`;
|
||
- at `DriverHostActor`, a stale snapshot is dropped under Warm and counted, and its role view does not move. The
|
||
Unset control does move. This is the first actor test of the driver host's ordering gate.
|
||
- `WarmRedundancyPooledWireTests` checks `standby.projected_notifications`: it equals the rewritten count, counts
|
||
again on Republish, and stays 0 while Active. It also checks `standby.suppressed_alarm_events`: one per withheld
|
||
transition, none once Active.
|
||
- Every listener selects by instrument instance.
|
||
- Mutations killed: each counter's `Add` was removed, the direction tag inverted, the gauge never set, and the
|
||
driver-host gate ignored.
|
||
|
||
Still open (live-only, T13): the durable restore, TransferSubscriptions under one identity, and the rig legs.
|