Files
lmxopcua/docs/deploy/2026-11-13-next-vd03-qa-to-c9640f5c.md
T
Joseph Doherty 0c19f26c81
v2-ci / unit-tests (push) Has been cancelled
fix(install): cut the swap's stopped window to the swapped-in folder (#905)
Root cause: the protected-DACL coverage scan, not the ACL writes. Both -Reapply and
-Verify walked every denied folder (all of E:\ApiInstall on vd03, nested roots again)
with Get-ChildItem -Recurse + Get-Acl per item + a pipeline per item for -Skip, about
3.4 ms an item on PS 5.1, all while the service was stopped. An unchanged deny is read,
not rewritten; the re-applied install-folder deny propagates over ~1,400 files in 0.5 s.

- Find-OtOpcUaDenyCoverageGap: .NET enumeration, -Skip folders pruned, DACL-only
  GetAccessControl(Access) (about 0.15 ms an item); reparse points not followed.
- Get-OtOpcUaCoverageWalkRoots: each denied folder walked once (outermost only).
- Install-ScriptWorkerIsolation.ps1 -Scope All|InstallRoot|Outside (with -Reapply,
  -Verify, -PlanOnly). InstallRoot = the folder ACEs a swap drops; Outside = the rest,
  including the firewall rule (its query costs 3-5 s; its exe path does not change).
  The two partition the plan. Prints the scan time.
- Invoke-OtOpcUaInstallSwap.ps1: -Reapply/-Verify -Scope Outside before the stop (a
  failure stops before anything moves), -Scope InstallRoot inside the window; preflight
  checks the candidate carries the worker exe; prints the stopped window and its parts.
  -NoStart, -NoCarry and the pre-#901 refusal unchanged.

windev, vd03-like tree (17,851 items): stopped window 153.1 s -> 6.0 s (PS 5.1),
101.6 s -> 6.2 s (PS 7); the Outside part takes ~23 s with the old build serving.
Dry-run harness 101 -> 123 passed; Windows test 72 passed on PS 5.1 and PS 7.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 03:51:42 -05:00

344 lines
30 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Next deploy: DEV vd03 `6c4d2990` and QA vq03/vq04 `fea7de0a` → master `c9640f5c`
> **EXECUTED 2026-11-13** (DEV vd03 07:33Z, QA pair 07:47Z): record [`2026-11-13-vd03-qa-to-c9640f5c.md`](2026-11-13-vd03-qa-to-c9640f5c.md).
> Deviations there: longer downtime from the in-swap `-Verify` coverage walk; the §5 #903 revert cannot return the chip to
> "In sync" (`RowVersion` is in the revision hash); QA Secondary swapped before the Primary stopped.
>
> **Status when written: PREPARED, NOT EXECUTED (2026-11-13).** This pack covers both tiers, plus the read-only ConfigDb preflight,
> which was run over direct SQL from the Mac on 2026-11-13. Nothing was built, staged or run on any wonder box. **No
> blocker found; no issue filed.**
>
> **Target:** `origin/master` **`c9640f5c`** (`c9640f5ced383e2a722702409adbc62298731994`, #904). If master moves before the window, either pin to
> `c9640f5c` (as the 6c4d2990 run pinned) or re-run §1–§3 for the new range.
>
> Templates: [`2026-11-13-vd03-fea7de0a-to-6c4d2990.md`](2026-11-13-vd03-fea7de0a-to-6c4d2990.md) (vd03 layout and
> scripts), [`qa-upgrade-b8b4c18f-to-fea7de0a.md`](qa-upgrade-b8b4c18f-to-fea7de0a.md) (QA window, canary, #890/#891
> denies, "Worker isolation across the next swap"), [`vd03-upgrade-b8b4c18f-to-master.md`](vd03-upgrade-b8b4c18f-to-master.md)
> §e/§f and "Worker isolation and box-wide denies".
## 1. Commit ranges and what changes
### vd03: `6c4d2990..c9640f5c` (9 commits)
| Commit | Change | Effect on vd03 (one fused node, one FOCAS driver, 22 tags, runner `InProcess`) |
|---|---|---|
| `efaf3435` #900 | HistorianGateway `FailedPrecondition` + `AGGREGATE_NOT_SUPPORTED_FOR_TAG` maps to `BadAggregateNotSupported`, with no health failure. Adds `Grpc.StatusProto 2.76.0`. | **Inert today.** vd03's HG `ea9f21c` predates historiangw#135 (`a220ec0`) and still answers `Internal`, which keeps the current handling. It takes effect when HG ≥ `a220ec0` is deployed. |
| `9375c9e2` | docs (the 6c4d2990 record) | — |
| `d5288388` #895 review, `c9640f5c` #904 | Galaxy alarm reverse map: re-areaed, subtag-provider and pre-subscription references. A picker-form ack waits up to 2 s for the feed snapshot. | Not reachable (no Galaxy driver). |
| `2470f82e` #872 | Galaxy status rows Pending/Warning → **Uncertain**; detail 8001 → `BadTypeMismatch`. A Pending write reply is now "not committed". | Not reachable. |
| `b85e004b` #902 | AdminUI: `MonacoEditor.DisposeAsync` on a gone circuit logs at Debug, not `[ERR]`. | Fixes the "Observed" `[ERR]` from the 6c4d2990 record. |
| `35576485` #903 | AdminUI `/deployments`: the drift chip is never a cached "In sync". The first render shows "Checking for changes...". A failed check shows "Drift check failed". | Fixes the stale "In sync" chip from the 6c4d2990 record. |
| `2cb8a2c3` #901 | Installer records its settings and gains `-Reapply`/`-Verify`. New `scripts/install/Invoke-OtOpcUaInstallSwap.ps1`. | Changes the deploy procedure (§4). No runtime change. |
| `f0c6cf96` #834 | Running Galaxy/OpcUaClient drivers **refuse** out-of-namespace credential refs at resolve time (the warn-only path is gone). The preflight logs one **Error** per finding, and the `/raw` banner is `alert-danger`. | FOCAS has no credential fields. Preflight: 0 findings (§3). Only the boot line wording changes (§5). |
### QA: `fea7de0a..c9640f5c` (46 commits: the 37 above `6c4d2990` plus the 9 vd03 commits)
The vd03 rows above, plus everything vd03 already got on 2026-11-13 (`fea7de0a..6c4d2990`, 37 commits):
- **Historian.**
- `ServerHistorian:Gateway:EnableNativeTimeWeighted` now **defaults to `true`** (#694, `53978ca6`). TimeAverage/Total
are advertised and served natively (12 aggregates). QA HG `fa9cf31` includes `9f711c1`, so it supports this.
- Alarm history goes out in `SendEvents` batches of ≤200, with a per-event fallback (#746).
- A Boolean node refuses TimeAverage/Total up front with `BadAggregateNotSupported` (#897). A String/DateTime node
refuses the numeric-only aggregates.
- `historianReadOnly: true` TagConfig plus the **new `ServerHistorian:ProvisionTags` setting** (#899).
- Float/Double/Byte/SByte historized tags are now provisioned (#898). See the upgrade hazard in §3.
- **Address space (#896):** a UNS reference to an alarm-bearing raw tag no longer gets a UNS value Variable. The
alarm surfaces only as the condition on the equipment folder.
- **Galaxy (#895):** picker-authored native alarms resolve and ack. Galaxy spans and `galaxy.events.*` counters are
exported (#892).
- **Telemetry 0.1.0 → 0.3.1** (scadaproj#55/#56).
- The OTel Resource carries `service.version` (the git SHA), `site.id` (the Cluster id) and `node.role`.
- **With `Exporter=Otlp`, Serilog logs go over OTLP too.** QA has `OtOpcUa__Telemetry__Exporter=Otlp` and
`OtlpEndpoint=http://127.0.0.1:4317` since 2026-11-12, so logs will start to reach the local `ZbOtelCollector`.
- 0.3 refuses a scheme-less `host:port` when `Exporter=Otlp`. The recorded value has `http://`, so it passes;
re-check it in the on-box preflight.
- **AdminUI #761 (`fa8c3d1a`):** a bodyless `POST /api/deployments` returned 404 on fused admin+driver nodes. It now
deploys.
- **Drivers.**
- AB Legacy MicroLogix function files are refused locally with `BadNotSupported`, not reported as a comms fault (#592).
- Heidenhain gains the `Controller/Family`, `Status/*StateName` and `Tool/AxisName` leaves, PLC
`INPUT_DWORD`/`OUTPUT_DWORD`, and new refusal-code mappings (#829/#853). Not reachable on QA.
- **Installer #890 (`f75ee7d0`):** `-DenyPaths`. Already applied on QA from staged scripts on 2026-11-12.
- Other commits are docs, tests or docker-dev only (#893).
### What a ScadaBridge consumer would notice
**On DEV and QA: nothing.** ScadaBridge on both tiers reads no OtOpcUa data; its only data connection is `MxGateway`
(QA pack §verification, vd03 fea7de0a section). For an OtOpcUa-bound ScadaBridge elsewhere:
- **Galaxy.**
- Pending/Warning rows now read **Uncertain**, not Good/Bad (#872).
- A Galaxy write that MXAccess answers Pending is reported **not committed**. The node reverts and the later commit
arrives as a data change.
- 8001 now reads `BadTypeMismatch`.
- **Alarm-bearing references (#896):** a UNS binding to a reference on an alarm-bearing tag now gets
`BadNodeIdUnknown`. Before, it read `BadWaitingForInitialData` forever. Bind the alarm as an event subscription.
- **HistoryRead-Processed:** TimeAverage/Total on a Boolean node now answers `BadAggregateNotSupported` (#897). With
HG ≥ `a220ec0`, the same holds for a numeric node backed by a discrete AVEVA tag (#900). TimeAverage/Total are
advertised again (QA range).
- **Credential refs (#834):** a Galaxy or OpcUaClient driver with an out-of-namespace credential reference no longer
connects. It is not a ScadaBridge-visible wire change, but its nodes go Bad.
- No proto, NodeId-scheme or ServiceLevel-semantics change. Contracts are unchanged.
## 2. Migrations and settings
- **ConfigDb migrations: none in either range.** The only file touched under `src/Core/ZB.MOM.WW.OtOpcUa.Configuration`
is `Validation/DraftValidator.cs` (#899 `HistorianReadOnlyInvalid` deploy rule, already on vd03). The repo head stays
`20261022102459_EnableSnapshotIsolation` (9 migrations). Both DBs are already there (§3).
- **New optional setting:** `ServerHistorian:ProvisionTags` = `CreateOrUpdate` (default, the previous behaviour) |
`CreateOnly` (Gateway backend only) | `Off`. An **unknown value, or `CreateOnly` on a SQL backend, fails host start**.
Neither tier sets it today (vd03 record). **Leave it unset:** there are 0 historized tags on either tier.
- **Changed default:** `ServerHistorian:Gateway:EnableNativeTimeWeighted` `false` → `true` (QA only; vd03 already has it).
The kill switch is `ServerHistorian__Gateway__EnableNativeTimeWeighted=false`. It is not needed: QA HG `fa9cf31` supports
native time-weighted reads.
- **Telemetry (QA):** no new keys. 0.3 reads the same `OtOpcUa:Telemetry` section and adds optional
`SiteId`/`NodeRole`/`ServiceVersion`/`ResourceAttributes:*` overrides.
- **Required env:** no new required variable. The existing required ones stay: `Security__ApiKeys__Pepper`
(≥16 chars) and the JWT key on both tiers, and `LocalDb__Replication__ApiKey`, identical on both QA nodes.
- **Packages:** `Grpc.StatusProto 2.76.0` (new). Telemetry(.Serilog) is 0.3.1 (already on vd03). LocalDb 0.3.7,
MxGateway.Client 0.4.0 and HistorianGateway.Client 1.0.0 are unchanged.
- **Peer services:** none to upgrade first. HG `ea9f21c` (vd03) and `fa9cf31` (QA) serve every RPC this build uses;
#900 is capability-tolerant. mxgw `76a71bc8` is unaffected, because neither tier has a Galaxy driver.
## 3. Read-only preflight (run 2026-11-13 from the Mac, direct SQL)
Run as `wwadmin` with `sqlcmd -C -I`, the password passed in `SQLCMDPASSWORD`, against `OtOpcUaConfig` on
`wonder-app-vd03.zmr.zimmer.com,1433` (DEV) and `wonder-sql-vq03.zmr.zimmer.com,1433` (QA). The queries were SELECTs only,
plus the existing script's local table variables. Two passes:
1. `scripts/preflight/vd03-preupgrade-b8b4c18f-configdb-checks.sql` unchanged (15 checks). It already reproduces
`DriverCredentialPolicy` / `CredentialReferenceDeployChecks` on the draft rows (checks 6/7).
2. Ad-hoc SELECTs for what the script does not cover:
- the **deployed** side of `CredentialReferencePreflight.ScanAsync`: the latest `Status=2` (Sealed) `ArtifactBlob`,
`DECOMPRESS`ed and searched;
- #898/#899/#897/#896 over `dbo.Tag.TagConfig` (`isHistorized`, `historianTagname`, `historianReadOnly`, `alarm`) and
`dbo.VirtualTag.Historize`.
| Check | DEV vd03 | QA (shared ConfigDb on wonder-sql-vq03) |
|---|---|---|
| `__EFMigrationsHistory` | 9 rows, head `20261022102459_EnableSnapshotIsolation` = repo head. Snapshot isolation ON, compat 160. | Same: 9 rows, same head, snapshot ON, compat 160. |
| Inventory | 1 driver (`FOCAS` `focas-z-34184`), 1 device, 22 tags (8 Double, 8 Int32, 6 String), 0 VT, 0 scripted alarms, 2 UNS refs, 10 deployments | 1 driver (`Calculation` `script-runner-canary`), 1 device, 1 tag (Int32), 1 VT (Int32), 0 scripted alarms, 0 UNS refs, 3 deployments |
| Latest Sealed deployment | `595cb909`, rev `fa9a2e28`, 2026-11-13 06:34Z (gzip, 13,655 B JSON) | `5905003e`, rev `82dd0598`, 2026-11-13 00:05Z (gzip, 4,146 B JSON) |
| **#834 draft**: script checks 6 (#815/#836 OutOfScope) and 7 (#835/#849 OtherInstance) | **ok, 0 rows** | **ok, 0 rows** |
| **#834 draft**: credential-ruled driver types (Galaxy / OpcUaClient / Heidenhain) and any `secret:`/`env:` text in DriverConfig/DeviceConfig | none. FOCAS has no credential fields, and neither config holds a reference. | none. Calculation has no credential fields; no reference. |
| **#834 deployed**: latest Sealed artifact contains `"Galaxy"` / `"OpcUaClient"` / `"Heidenhain"` / `secret:` / `env:` | 0 / 0 / 0 / 0 / 0 | 0 / 0 / 0 / 0 / 0 |
| → #834 verdict | **No finding.** The boot preflight will log "every stored and deployed reference is namespaced". | **No finding.** |
| **#898** historized Float/Double/Byte/SByte tags (first start would `EnsureTags`) | 0 (0 tags with `isHistorized: true` at all; no `historianTagname`) | 0 (no historized tag; the VT has `Historize=0`) |
| **#899** tags with a `historianReadOnly` key / a non-boolean value (`HistorianReadOnlyInvalid`) | 0 / 0 | 0 / 0 |
| **#899** `ProvisionTags` default | Nothing to provision, so the default `CreateOrUpdate` is harmless. | Same. |
| **#897** historized Boolean tags/VTs (TimeAverage/Total now refused up front) | 0 (no Boolean tags at all). Aggregates are chosen per client request, not stored in config; no historized Boolean node can receive one. | 0 |
| **#896** UNS references to alarm-bearing tags | 0 (no tag has an `alarm` object) | 0 |
| Other script checks (#783, Calc trigger, #791 ×2, #792, #848, MTConnect, #781 Sql, #803 Heidenhain, UNS collisions) | all **ok** | all **ok** |
| Script check 0 "Environment" | `attention`: a stale expectation. The script was written for `b8b4c18f`, and the migration it asks for is already applied. Not an issue. | Same. |
| Script check 13 (FOCAS renames, info) | 9 info rows. These are the b8b4c18f→master FOCAS address notes, already live since the 2026-11-12 deploy. | ok |
**Verdict: no blocker on either tier; no issue filed.** Re-run both passes just before the window if the configuration
has changed since 2026-11-13. On QA the canary is the only configuration.
### Pack correction found during preflight: QA records 12 deny paths, not 11
The 2026-11-12 OTel collector install (scadaproj `infra/otel-collector/wonder/2026-11-12-wonder-otel-collector.md`,
21:46–21:47) re-ran the installer on vq03/vq04 and added **`E:\ApiInstall\OtelCollector`** (`DenyPathRecord` +
`SensitiveDirDeny` changed). The QA pack's 11-path list is therefore one short. If the one-time full-argument run
(§4) used the 11-path list, it would **remove** the collector deny. §4 uses the 12-path list. As before, the rule is to
use exactly what `reg query` shows.
The same record also shows that the OtOpcUa Primary failed over to **vq04** during the restarts at 21:49–21:50. Read
ServiceLevel before the window to know which node is Primary now.
## 4. Build, stage, one-time isolation record, swap
### Build (Mac, isolated worktree at `c9640f5c`; not done here)
```bash
git worktree add ../OtOpcUa-wt-c9640f5c c9640f5c && cd ../OtOpcUa-wt-c9640f5c
dotnet publish src/Server/ZB.MOM.WW.OtOpcUa.Host/ZB.MOM.WW.OtOpcUa.Host.csproj -c Release -r win-x64 --self-contained true -o ../publish-c9640f5c
# expect ~1396+ files, OtOpcUa.Host.dll ProductVersion 1.0.0+c9640f5c…, script-worker\ZB.MOM.WW.OtOpcUa.ScriptWorker.exe present;
# deps.json: Telemetry(.Serilog) 0.3.1, LocalDb 0.3.7, MxGateway.Client 0.4.0, HistorianGateway.Client 1.0.0, Grpc.StatusProto 2.76.0
cd ../publish-c9640f5c && zip -qr ../otopcua-c9640f5c.zip . && shasum -a 256 ../otopcua-c9640f5c.zip > ../otopcua-c9640f5c.zip.sha256
```
Copy the zip and `.sha256` over SMB into the staging folders below, and check the hash on the box before expanding.
Stage the three install scripts from `c9640f5c` next to them. Their SHA-256 values at `c9640f5c`:
| File | SHA-256 |
|---|---|
| `scripts/install/Install-ScriptWorkerIsolation.ps1` | `7d4078cb93a42b362ab50ba5b79bc293bf92001d5444f58d5c6733e0d51c4914` |
| `scripts/install/ScriptWorkerIsolation.psm1` | `ae9d84fd0077a730ecaaf01b8d476ee83755c2d3fb163e752379c276f227d902` |
| `scripts/install/Invoke-OtOpcUaInstallSwap.ps1` | `9498fd8092c3b2ea95f7c7f8275b704d6bed99dfeea0dcfadfbab1045d79e88d` |
All remote steps below are on-box deploy steps (`winrm` skill, deploy scope). Run them in an elevated Windows
PowerShell, from the staged `install\` folder. **Never run `Install-Services.ps1`, `Uninstall-Services.ps1` or
`Refresh-Services.ps1`** (vd03 pack §e step 5).
### DEV vd03 (`E:\ApiInstall\OtOpcUa`, data in `E:\ApiInstall\OtOpcUa-data`, runner `InProcess`)
Staging: `E:\ApiInstall\_stage-otopcua-c9640f5c\` (zip, `.sha256`, `install\`). Backups go to
`E:\ApiInstall\OtOpcUa-backups\pre-20261113-otopcua-c9640f5c\`. Create that folder with a protected DACL (SYSTEM +
Administrators only, #891).
1. **Prepare (service up).**
- `reg export HKLM\SYSTEM\CurrentControlSet\Services\OtOpcUaHost` into the backup folder.
- Check the hash, then expand to `E:\ApiInstall\OtOpcUa.new-c9640f5c` and check `ProductVersion`.
- `BACKUP DATABASE [OtOpcUaConfig] TO DISK = N'OtOpcUaConfig-pre-20261113-otopcua-c9640f5c.bak' WITH COPY_ONLY, CHECKSUM`.
There is no migration, so this is only a configuration fallback.
- Read the service env (names and count only; expect 28). Check that `OtOpcUa__Telemetry__OtlpEndpoint` has a scheme.
2. **One-time #901 settings record** (service can stay up; vd03 was isolated by the pre-#901 installer, so
`Invoke-OtOpcUaInstallSwap.ps1` refuses until the record exists):
```powershell
reg query HKLM\SYSTEM\CurrentControlSet\Services\OtOpcUaScriptWorker\Parameters /v DenyPaths
# expect exactly: E:\ApiInstall, E:\ApiInstall\OtOpcUa\pki, E:\ApiInstall\OtOpcUa-data, C:\ProgramData\ZB\kek, E:\psrem-stage
.\Install-ScriptWorkerIsolation.ps1 -InstallRoot E:\ApiInstall\OtOpcUa -HostServiceAccount LocalSystem `
-DenyPaths E:\ApiInstall,E:\ApiInstall\OtOpcUa\pki,E:\ApiInstall\OtOpcUa-data,C:\ProgramData\ZB\kek,E:\psrem-stage -WhatIf
.\Install-ScriptWorkerIsolation.ps1 -InstallRoot E:\ApiInstall\OtOpcUa -HostServiceAccount LocalSystem `
-DenyPaths E:\ApiInstall,E:\ApiInstall\OtOpcUa\pki,E:\ApiInstall\OtOpcUa-data,C:\ProgramData\ZB\kek,E:\psrem-stage
.\Install-ScriptWorkerIsolation.ps1 -Verify # VERIFY OK, exit 0
reg query HKLM\SYSTEM\CurrentControlSet\Services\OtOpcUaScriptWorker\Parameters /v DenyPaths # same 5 paths
```
- **No `-ConfigureHostService`:** the vd03 runner stays `InProcess` (vd03 pack §"Worker isolation and box-wide denies").
- Expect **`SettingsRecord` changed**, `DenyPathRecord` unchanged, and every other step unchanged. The `reisolate.ps1`
run after the 6c4d2990 swap restored them.
- The "protected DACL" WARNs under `E:\psrem-stage` and the locked backups are pre-existing and expected.
- If `reg query` lists anything other than the 5 paths, stop and use the recorded list.
3. **Swap.**
- `Stop-Service OtOpcUaHost`.
- `robocopy E:\ApiInstall\OtOpcUa-data <backup>\OtOpcUa-data /E /COPY:DAT` (stopped, so the SQLite triplets are consistent).
- Then run:
```powershell
.\Invoke-OtOpcUaInstallSwap.ps1 -InstallRoot E:\ApiInstall\OtOpcUa -Candidate E:\ApiInstall\OtOpcUa.new-c9640f5c `
-PreviousInstall E:\ApiInstall\OtOpcUa.bak.20261113-pre-c9640f5c
```
- The default `-Carry` (`appsettings*.json`, `pki`, `logs`) is right for vd03.
- The script tolerates an already-stopped service. It moves the folders, carries the box files, runs `-Reapply`
(expect `WorkerFolderAcl`, `InstallRootDeny` and the `pki` `SensitiveDirDeny` **changed**), then `-Verify`, then starts.
- **Gate:** the script must finish without throwing. A failed `-Verify` leaves the service **stopped**: fix the
problem, re-run `-Reapply`/`-Verify`, then start.
- After the start, run `.\Install-ScriptWorkerIsolation.ps1 -Verify` once more and record its output (exit 0).
### QA vq03 + vq04 (stop both, swap both, start both)
Layout: `E:\ApiInstall\OtOpcUa\{app,data,pki}`, service `OtOpcUaHost` (LocalSystem), runner `OutOfProcess` (Calculation +
VirtualTag). Staging: `E:\psrem-stage\otopcua-c9640f5c\` (zip, `.sha256`, `install\`). Backups go to
`E:\psrem-stage\otopcua-c9640f5c\backup\`, created with a protected DACL (#891).
1. **Prepare (both nodes, services up).**
- Expand to `E:\ApiInstall\OtOpcUa\app.new-c9640f5c` (check the hash and ProductVersion).
- `reg export …\OtOpcUaHost backup\OtOpcUaHost-pre-c9640f5c.reg`.
- Read the env names and count: expect 48 on vq03 and 47 on vq04, including `Scripting__Runner*`,
`Scripting__Worker__*`, the pepper, `LocalDb__Replication__ApiKey` and `OtOpcUa__Telemetry__*`. Check that
`OtlpEndpoint` has a scheme.
- Once: `BACKUP DATABASE OtOpcUaConfig … COPY_ONLY, CHECKSUM, COMPRESSION` on wonder-sql-vq03 →
`OtOpcUaConfig_pre-c9640f5c_20261113.bak`, then `RESTORE VERIFYONLY`.
- Read ServiceLevel on both nodes to learn which one is Primary (250). It may be **vq04** since the 2026-11-12 OTel restarts.
2. **One-time #901 settings record (both nodes, services up).** QA was isolated by the pre-#901 installer
(DenyPaths only):
```powershell
reg query HKLM\SYSTEM\CurrentControlSet\Services\OtOpcUaScriptWorker\Parameters /v DenyPaths
# expect these 12 (the 11 #891 paths + the OTel collector folder added 2026-11-12):
$deny = 'E:\ApiInstall\OtOpcUa','E:\ApiInstall\OtOpcUa\pki','E:\ApiInstall\OtOpcUa\data','C:\ProgramData\ZB\kek',
'E:\ApiInstall\ScadaBridge','E:\ApiInstall\HistorianGateway','E:\ApiInstall\MxAccessGateway','E:\ApiInstall\Overview',
'E:\ApiInstall\btdbmanager','E:\psrem-stage','E:\psrem','E:\ApiInstall\OtelCollector'
.\Install-ScriptWorkerIsolation.ps1 -InstallRoot E:\ApiInstall\OtOpcUa\app -HostServiceAccount LocalSystem -ConfigureHostService -DenyPaths $deny -WhatIf
.\Install-ScriptWorkerIsolation.ps1 -InstallRoot E:\ApiInstall\OtOpcUa\app -HostServiceAccount LocalSystem -ConfigureHostService -DenyPaths $deny
.\Install-ScriptWorkerIsolation.ps1 -Verify # VERIFY OK, exit 0
reg query HKLM\SYSTEM\CurrentControlSet\Services\OtOpcUaScriptWorker\Parameters /v DenyPaths # same 12 paths
```
- If `reg query` differs from the 12 above, use **exactly the recorded list**. A missing entry in `$deny` removes that
deny.
- `-ConfigureHostService` stays, because QA's runner flip used it.
- Expect **`SettingsRecord` changed** and `DenyPathRecord` unchanged.
- `HostServiceEnv` may report **changed** as a reorder only, as in the #890 run, if the OTel entries were appended
after the `Scripting__Worker__*` pair. Confirm the env count is unchanged (48/47) and that no value changed
(compare SHA-256 prefixes, never print values). Every other step should be unchanged.
- The vq04 `kek\historiangw.kek`/`mxgateway.kek` and locked `.reg` protected-DACL WARNs are expected.
3. **Stop both.** Stop the Secondary (240) first, then the Primary (250). On each node, while stopped, run
`robocopy data backup\data-pre-c9640f5c /E /COPY:DAT` and the same for `pki`.
4. **Swap each node** (services stopped):
```powershell
.\Invoke-OtOpcUaInstallSwap.ps1 -InstallRoot E:\ApiInstall\OtOpcUa\app -Candidate E:\ApiInstall\OtOpcUa\app.new-c9640f5c `
-PreviousInstall E:\ApiInstall\OtOpcUa\app.bak.20261113-pre-c9640f5c -Carry 'appsettings*.json','logs' -NoStart
```
- `pki\` and `data\` sit beside `app\` and are not moved.
- Expect the re-apply to report `WorkerFolderAcl` and `InstallRootDeny` changed, then `-Verify` OK.
- **Gate: the script returns without throwing on both nodes.** If `-Verify` fails on either node, do not start
either; fix it, then run `-Reapply` and `-Verify`.
5. **Start both.** Start the node that was Primary first; it waits for its peer, about 40 s last time. Then start the
other node.
6. On each node, after ready: `.\Install-ScriptWorkerIsolation.ps1 -Verify` → `VERIFY OK`, exit 0. Record the output.
## 5. Post-deploy gates
Run these from the Mac over HTTP / opc.tcp. Read logs over SMB (`logs\otopcua-YYYYMMDD.log`). The Windows-listed size of
an open log reads 0; read its contents.
| Gate | DEV vd03 | QA vq03 + vq04 |
|---|---|---|
| Isolation | `-Verify` exit 0 after the swap and after the start (§4) | same, both nodes |
| Version | live `OtOpcUa.Host.dll` (SMB copy) ProductVersion `1.0.0+c9640f5c…`; SHA-256 equals the published build | same, both nodes |
| Health | `/healthz`, `/health/ready`, `/health/active` all 200 on `:9000` | `/health/ready` 200 on both, with 5/5 components including `Out-of-process script runner ready.`; `/health/active` 200 on the Primary, 503 on the Secondary |
| ServiceLevel | **250** | **250 / 240**, stable over repeated fresh-session reads |
| Failover (QA) | — | Stop the Primary: the other node reaches **250** and `/health/active` 200. Restart the old Primary: **240**, never above, **no failback**. |
| LocalDb sync (QA) | — | `localdb-replication` connected, oplog backlog 0 on both, before and after the failover |
| Canary (QA) | — | `ns=2;s=script-runner-canary/Device1/canary-calc-seconds` and `ns=3;s=EQ-ec3979550d90/canary-vt-second` are **Good and advancing about once a second** on both endpoints. `otopcua_script_worker_up` = 1 per shard. The #780 runaway drill (`while(true)` VT, expect 2 kills + quarantine, siblings Good, 250/240 unchanged, then delete and redeploy back to rev `82dd0598…`) is **optional**. |
| Driver data | FOCAS raw: 22 variables, 21 Good, `Program/BlockCount` `BadNoData` (as before) | the canary above |
| Boot log | `roles=[admin,driver]`; **`Credential-reference preflight (lmxopcua#815/#834): every stored and deployed reference is namespaced.`** (the new wording; any `Error` line from this preflight is a stop); `Historian gateway probe: the gateway is reachable`; no `FTL` | same, both nodes; also no `Telemetry` endpoint FATAL (0.3 check) |
| **#903 drift chip** | On `/deployments` (login disabled on DEV): the first render shows **"Checking for changes..."**, then "In sync". Make a harmless draft change, for example a tag description on `/raw`, with no deploy. Reload `/deployments`: it must show **"Configuration drift"** at once. Revert the change: the chip returns to "In sync", and the revision is still `fa9a2e28…`. | Optional. The QA AdminUI needs the `localhost` forwarder plus a temporary role-mapping row (QA pack §2). If you do it, make the change on the canary and revert it. Delete the temporary row afterwards. |
| **#902 Monaco** | Open `/scripts/new` (the Monaco editor) and close the browser tab without saving. Then search the log after that time for `MonacoEditor` / `Unhandled exception in circuit`: expect **no `[ERR]`** (it is Debug now). | Same if the AdminUI is opened; otherwise n/a |
| **Historian writes** | HG `http://wonder-app-vd03…:5220/metrics` `historian_gateway_grpc_requests_total`: snapshot before the stop and about 2 min after ready. Only `HistorianStatus/Probe` should grow. **No `EnsureTags`, `AddTagExtendedProperties`, `WriteLiveValues`, `AddHistoricalValues`, `SendEvent(s)`.** | Same on vq03's HG `:5220/metrics`; both QA nodes point at `10.220.158.2:5221` |
| OTLP logs (QA) | — (vd03 already sends logs) | New: the collector's file exporter on each box starts receiving OtOpcUa log records. Check over SMB, read-only. Not a gate. |
| Overview | `:5320` shows OtOpcUa Up | vq03/vq04 `:5320`: OtOpcUa Up, 2 members / 0 unreachable, 5/5 checks |
| ScadaBridge | `/health/ready` 200 (no OtOpcUa link) | `/health/ready` 200 on both (no OtOpcUa link) |
## 6. Rollback
There is no schema undo in either range: no migration. The ConfigDb `.bak` exists only for a configuration restore.
**DEV vd03 → `6c4d2990`:**
```powershell
.\Invoke-OtOpcUaInstallSwap.ps1 -InstallRoot E:\ApiInstall\OtOpcUa -Candidate E:\ApiInstall\OtOpcUa.bak.20261113-pre-c9640f5c `
-PreviousInstall E:\ApiInstall\OtOpcUa.failed-c9640f5c -NoCarry -NoStart
```
- The script stops the service, swaps the complete previous folder back (its own `appsettings*`, `pki`, `logs`), then
runs `-Reapply` + `-Verify`. The service stays stopped.
- Then mirror `<backup>\OtOpcUa-data` back over `E:\ApiInstall\OtOpcUa-data` and `Start-Service OtOpcUaHost`.
- Run `-Verify` again, then check health and ServiceLevel 250.
- The registry is unchanged by this deploy, so no import is needed.
- Fallback: `E:\ApiInstall\_stage-otopcua-6c4d2990\rollback.ps1` is one generation older and targets `fea7de0a`. Do not
use it for this rollback.
**QA → `fea7de0a`:** stop both, then on each node:
```powershell
.\Invoke-OtOpcUaInstallSwap.ps1 -InstallRoot E:\ApiInstall\OtOpcUa\app -Candidate E:\ApiInstall\OtOpcUa\app.bak.20261113-pre-c9640f5c `
-PreviousInstall E:\ApiInstall\OtOpcUa\app.failed-c9640f5c -NoCarry -NoStart
```
- After the swap, mirror `backup\data-pre-c9640f5c` back over `data\`.
- Import `backup\OtOpcUaHost-pre-c9640f5c.reg` only if step 2's `-ConfigureHostService` changed the env. A reorder
is harmless.
- Run `-Verify` on each node (exit 0), then start both, the old Primary first.
- The isolation record and denies stay valid for `fea7de0a`. The installer works independently of the host build.
- DB fallback: `OtOpcUaConfig_pre-c9640f5c_20261113.bak`.
- SDK tooling caveat: not applicable. Both builds are on SDK 2.0.1.
**Isolation step only (§4 step 2):** the settings record is additive. Re-running the installer with the same arguments
is idempotent. `-Uninstall` removes everything, including the recorded denies; do not run it as part of a binary
rollback.
## 7. Downtime estimates (from the previous records)
| Tier | Previous | Estimate for this pack |
|---|---|---|
| vd03 | `fea7de0a` about **10 s** (stop 2 s); `6c4d2990` about **15 s** (stop 6 s), stop → `/health/ready` | **about 20–40 s.** The data robocopy and the in-script `-Reapply`/`-Verify` now run while the service is stopped. The step-2 record write happens with the service up. |
| QA pair | `fea7de0a` window **about 2 min** pair outage (16:48:13 → 16:50:14), of which about 70 s was the isolation install + uninstall drill. The first node took 39 s to ready because it waits for its peer; the second took 8 s. | **about 1–1.5 min** pair outage: stops about 1–2 s each, backup + swap + `-Reapply`/`-Verify` per node, then about 40 s + 8 s to ready. One-node restarts (the OTel record) took up to 32 s to stop a Secondary with its peer up. Stopping both together avoids that graceful-leave wait. |
| QA failover gate | 30 s graceful leave, then the new Primary at 250 on its first sample | same |
**After lmxopcua#905 (for the next pack that uses `Invoke-OtOpcUaInstallSwap.ps1`).** The 101 s (vd03) and 50–60 s per
QA node were the protected-DACL coverage scan (`Get-Acl` per item over every denied folder, in both `-Reapply` and
`-Verify`, while stopped), not the ACL writes. The swap now runs `-Reapply`/`-Verify -Scope Outside` (the full scan
included) **before** the stop and only `-Scope InstallRoot` inside the window. windev, a vd03-like tree of 17,851 items
under the denied folder: stopped window **153.1 s → 6.0 s** (Windows PowerShell 5.1) and **101.6 s → 6.2 s** (PowerShell 7);
the pre-stop part takes about 23 s with the old build still serving. Estimate for the next vd03 swap: stop (2–6 s) +
the `data\` backup + about 6 s + start-up to `/health/ready` (about 8–10 s), i.e. **about 20–30 s**. QA: about 10 s of
swap per node inside the pair outage instead of 50–60 s, and the Secondary-first order (deviation 3) is no longer needed
to hide it. The script prints `stopped window (…): N s [stop, move, carry, isolation]`; record that line.