Files
lmxopcua/tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests/OpcUa/OpcUaPublishActorEndpointStateTests.cs
T
Joseph Doherty b211911f98
v2-ci / unit-tests (push) Failing after 13m22s
test: migrate AdminUI/ControlPlane/Runtime/Host tests to xunit.v3 (#756)
Akka.TestKit.Xunit2 -> Akka.TestKit.Xunit 1.5.62 (xunit.v3 TestKit; needs xunit.v3 3.2.2, set via
VersionOverride on the four projects). Removes the xunit 2.9.3 pin. IAsyncLifetime returns ValueTask,
SqlServerFactAttribute gains the source-info ctor, and xUnit1051 call sites pass
TestContext.Current.CancellationToken. Test counts unchanged.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 08:57:33 -05:00

120 lines
5.9 KiB
C#

using System.Collections.Concurrent;
using Akka.Actor;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Commons.Messages.Redundancy;
using ZB.MOM.WW.OtOpcUa.Commons.OpcUa;
using ZB.MOM.WW.OtOpcUa.Commons.Types;
using ZB.MOM.WW.OtOpcUa.Runtime.Health;
using ZB.MOM.WW.OtOpcUa.Runtime.OpcUa;
using ZB.MOM.WW.OtOpcUa.Runtime.Tests.Harness;
namespace ZB.MOM.WW.OtOpcUa.Runtime.Tests.OpcUa;
/// <summary>
/// lmxopcua#762: a node whose own OPC UA SDK failed to start must not advertise 250/240. Each test pairs the
/// failed endpoint with a positive control — the SAME actor wiring and snapshot with a started endpoint — so a
/// 0 cannot come from some other demotion (Detached, a missing entry, a peer probe).
/// </summary>
public sealed class OpcUaPublishActorEndpointStateTests : RuntimeActorTestBase
{
/// <summary>DB-less driver node (the survive-alone posture): Primary would be 250, a failed endpoint is 0.</summary>
[Theory]
[InlineData(true, 250)]
[InlineData(false, 240)]
public void DbLess_failed_endpoint_publishes_zero_instead_of_healthy_level(bool primary, byte healthy)
{
PublishedLevelFor(OpcUaEndpointStatus.Started, primary, dbLess: true).ShouldBe(healthy, "positive control");
PublishedLevelFor(OpcUaEndpointStatus.Failed, primary, dbLess: true).ShouldBe((byte)0);
}
/// <summary>DB-backed node on the full calculator path (DB reachable, fresh): same rule.</summary>
[Fact]
public void DbBacked_failed_endpoint_publishes_zero_instead_of_250()
{
PublishedLevelFor(OpcUaEndpointStatus.Started, primary: true, dbLess: false, dbBacked: true).ShouldBe((byte)250, "positive control");
PublishedLevelFor(OpcUaEndpointStatus.Failed, primary: true, dbLess: false, dbBacked: true).ShouldBe((byte)0);
}
/// <summary>The legacy role-only seam (no DB probe wired yet) must not hand a failed endpoint 240 either.</summary>
[Fact]
public void Legacy_role_only_seam_failed_endpoint_publishes_zero_instead_of_240()
{
PublishedLevelFor(OpcUaEndpointStatus.Started, primary: true, dbLess: false).ShouldBe((byte)240, "positive control");
PublishedLevelFor(OpcUaEndpointStatus.Failed, primary: true, dbLess: false).ShouldBe((byte)0);
}
/// <summary>
/// Boot (<see cref="OpcUaEndpointStatus.NotStarted"/>) and shutdown (<see cref="OpcUaEndpointStatus.Stopped"/>)
/// are not faults: only a recorded start FAILURE demotes.
/// </summary>
[Theory]
[InlineData(OpcUaEndpointStatus.NotStarted)]
[InlineData(OpcUaEndpointStatus.Stopped)]
public void Only_a_failed_start_demotes(OpcUaEndpointStatus status)
{
PublishedLevelFor(status, primary: true, dbLess: true).ShouldBe((byte)250);
}
/// <summary>
/// The fact is read on every recompute, so an endpoint that fails after the first healthy publish demotes on
/// the next health tick without any message being sent to the actor.
/// </summary>
[Fact]
public void Endpoint_failing_later_demotes_on_the_next_tick()
{
var publisher = new RecordingPublisher();
var state = new OpcUaEndpointState();
state.MarkStarted();
var local = NodeId.Parse("endpoint-later-node");
var actor = Sys.ActorOf(OpcUaPublishActor.PropsForTests(
serviceLevel: publisher, localNode: local, dbLess: true,
healthTickInterval: TimeSpan.FromMilliseconds(25), endpointState: state));
actor.Tell(Snapshot(local, primary: true));
AwaitAssert(() => publisher.Levels.ShouldBe(new byte[] { 250 }), PresenceBudget, cancellationToken: TestContext.Current.CancellationToken);
state.MarkFailed("port 4840 in use");
AwaitAssert(() => publisher.Levels.ShouldBe(new byte[] { 250, 0 }), PresenceBudget, cancellationToken: TestContext.Current.CancellationToken);
}
private byte PublishedLevelFor(OpcUaEndpointStatus status, bool primary, bool dbLess, bool dbBacked = false)
{
var publisher = new RecordingPublisher();
var state = new OpcUaEndpointState();
switch (status)
{
case OpcUaEndpointStatus.Started: state.MarkStarted(); break;
case OpcUaEndpointStatus.Failed: state.MarkFailed("port 4840 in use"); break;
case OpcUaEndpointStatus.Stopped: state.MarkStopped(); break;
}
var local = NodeId.Parse($"endpoint-{Guid.NewGuid():N}");
// A DB-backed actor needs a probe ref to leave the legacy seam; its Ask is never answered here (the 5-min
// tick keeps it to the one start-up Ask), and a healthy sample is Told directly BEFORE the snapshot so the
// snapshot's recompute — the first publish — runs the full calculator path.
var db = dbBacked ? CreateTestProbe() : null;
var actor = Sys.ActorOf(OpcUaPublishActor.PropsForTests(
serviceLevel: publisher, localNode: local, dbLess: dbLess, dbHealthProbe: db?.Ref,
healthTickInterval: TimeSpan.FromMinutes(5), endpointState: state));
if (db is not null)
actor.Tell(new DbHealthProbeActor.DbHealthStatus(true, DateTime.UtcNow, null));
actor.Tell(Snapshot(local, primary));
AwaitAssert(() => publisher.Levels.Length.ShouldBeGreaterThanOrEqualTo(1), PresenceBudget);
Sys.Stop(actor);
return publisher.Levels[0];
}
private static RedundancyStateChanged Snapshot(NodeId local, bool primary) =>
new(new[] { new NodeRedundancyState(local,
primary ? RedundancyRole.Primary : RedundancyRole.Secondary,
IsClusterLeader: primary, IsDriverPrimary: primary, DateTime.UtcNow) }, CorrelationId.NewId());
private sealed class RecordingPublisher : IServiceLevelPublisher
{
private readonly ConcurrentQueue<byte> _levels = new();
public byte[] Levels => _levels.ToArray();
public void Publish(byte serviceLevel) => _levels.Enqueue(serviceLevel);
}
}