Files
lmxopcua/CLAUDE.md
2026-04-06 23:30:07 -04:00

113 lines
7.4 KiB
Markdown

# CLAUDE.md
This file provides guidance to Claude Code (claude.ai/code) when working with code in this repository.
## Project Goal
Build an OPC UA server on .NET Framework 4.8 (32-bit) that exposes AVEVA System Platform (Wonderware) Galaxy tags via the MXAccess toolkit. The server mirrors the Galaxy object hierarchy as an OPC UA address space, translating between contained-name browse paths and tag-name runtime references.
## Architecture Overview
### Data Flow
1. **Galaxy Repository DB (ZB)** — SQL Server database holding the deployed object hierarchy and attribute definitions. Queried at startup and on change detection to build/rebuild the OPC UA address space.
2. **MXAccess COM API** — Runtime data access layer. Subscribes to Galaxy tag attributes for live read/write. Requires a dedicated STA thread with a Win32 message pump for COM callbacks.
3. **OPC UA Server** — Exposes the hierarchy as browse nodes and attributes as variable nodes. Clients browse via contained names but reads/writes are translated to `tag_name.AttributeName` format for MXAccess.
### Key Concept: Contained Name vs Tag Name
Galaxy objects have two names:
- **contained_name** — human-readable name scoped to parent (used for OPC UA browse tree)
- **tag_name** — globally unique system name (used for MXAccess read/write)
Example: browsing `TestMachine_001/DelmiaReceiver/DownloadPath` translates to MXAccess reference `DelmiaReceiver_001.DownloadPath`.
See `gr/layout.md` for the full mapping and target OPC UA structure.
### Data Type Mapping
Galaxy `mx_data_type` values map to OPC UA types (Boolean, Int32, Float, Double, String, DateTime, etc.). Array attributes use ValueRank=1 with ArrayDimensions from the Galaxy attribute definition. Full mapping in `gr/data_type_mapping.md`.
### Change Detection
Poll `galaxy.time_of_last_deploy` in the ZB database to detect redeployments, then rebuild the address space. See `gr/build_layout_plan.md` for the step-by-step plan.
## Reference Implementation
An existing MXAccess client implementation is at:
`C:\Users\dohertj2\Desktop\scadalink-design\lmxproxy\src\ZB.MOM.WW.LmxProxy.Host`
Key patterns from that codebase:
- **StaComThread** — Dedicated STA thread with Win32 message pump (`GetMessage`/`DispatchMessage` loop). All MXAccess COM objects must be created and called on this thread. Uses `PostThreadMessage(WM_APP)` to marshal work items.
- **LMXProxyServer COM object** — `Register(clientName)` returns a connection handle. `AddItem(handle, address)` + `AdviseSupervisory(handle, itemHandle)` for subscriptions. `OnDataChange`/`OnWriteComplete` events for callbacks.
- **Reconnect** — Stored subscriptions are replayed after reconnect. A probe tag subscription monitors connection health.
- **COM cleanup** — `Marshal.ReleaseComObject()` on disconnect. Event handlers must be unwired before unregister.
## MXAccess Documentation
`mxaccess_documentation.md` in the project root contains the full ArchestrA MXAccess Toolkit User's Guide. Key API: `ArchestrA.MxAccess` namespace, `LMXProxyServer` class. The toolkit DLLs are in `Program Files (x86)\ArchestrA\Framework\bin`.
## Galaxy Repository Database
Connection: `sqlcmd -S localhost -d ZB -E` (Windows Auth). See `gr/connectioninfo.md`.
The `gr/` folder contains:
- `queries/` — SQL for hierarchy extraction, attribute lookup, and change detection
- `ddl/tables/` and `ddl/views/` — Schema definitions
- `schema.md` — Full table/view reference
- `build_layout_plan.md` — Step-by-step plan for building the OPC UA address space from DB queries
- `gr/CLAUDE.md` — Detailed guidance for working within the `gr/` subfolder
Key tables: `gobject` (hierarchy/deployment), `template_definition` (object categories), `dynamic_attribute` (user-defined attributes), `primitive_instance` (primitive-to-attribute links), `galaxy` (change detection).
## Build Commands
```bash
dotnet restore ZB.MOM.WW.LmxOpcUa.slnx
dotnet build ZB.MOM.WW.LmxOpcUa.slnx
dotnet test ZB.MOM.WW.LmxOpcUa.slnx # all tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Tests # unit tests only
dotnet test tests/ZB.MOM.WW.LmxOpcUa.IntegrationTests # integration tests only
dotnet test --filter "FullyQualifiedName~MyTestClass.MyMethod" # single test
```
## Build & Runtime Constraints
- Language: C#, .NET Framework 4.8, **x86 (32-bit)** platform target — required for MXAccess COM interop
- MXAccess requires a deployed ArchestrA Platform on the machine running the server
- COM apartment: MXAccess objects must live on an STA thread with a message pump
## Transport Security
The server supports configurable OPC UA transport security via the `Security` section in `appsettings.json`. Phase 1 profiles: `None` (default), `Basic256Sha256-Sign`, `Basic256Sha256-SignAndEncrypt`. Security profiles are resolved by `SecurityProfileResolver` at startup. The server certificate is always created even for `None`-only deployments because `UserName` token encryption depends on it. See `docs/security.md` for the full guide.
## Redundancy
The server supports non-transparent warm/hot redundancy via the `Redundancy` section in `appsettings.json`. Two instances share the same Galaxy DB and MXAccess runtime but have unique `ApplicationUri` values. Each exposes `RedundancySupport`, `ServerUriArray`, and a dynamic `ServiceLevel` based on role and runtime health. The primary advertises a higher ServiceLevel than the secondary. See `docs/Redundancy.md` for the full guide.
## LDAP Authentication
The server uses LDAP-based user authentication via the `Authentication.Ldap` section in `appsettings.json`. When enabled, credentials are validated by LDAP bind against a GLAuth server (installed at `C:\publish\glauth\`), and LDAP group membership maps to OPC UA permissions: `ReadOnly` (browse/read), `WriteOperate` (write FreeAccess/Operate attributes), `WriteTune` (write Tune attributes), `WriteConfigure` (write Configure attributes), `AlarmAck` (alarm acknowledgment). `LdapAuthenticationProvider` implements both `IUserAuthenticationProvider` and `IRoleProvider`. See `docs/Security.md` for the full guide and `C:\publish\glauth\auth.md` for LDAP user/group reference.
## Library Preferences
- **Logging**: Serilog with rolling daily file sink
- **Unit tests**: xUnit + Shouldly for assertions
- **Service hosting**: TopShelf (Windows service install/uninstall/run as console)
- **OPC UA**: OPC Foundation UA .NET Standard stack (https://github.com/opcfoundation/ua-.netstandard) — NuGet: `OPCFoundation.NetStandard.Opc.Ua.Server`
## OPC UA .NET Standard Documentation
Use the DeepWiki MCP (`mcp__deepwiki`) to query documentation for the OPC UA .NET Standard stack: `https://deepwiki.com/OPCFoundation/UA-.NETStandard`. Tools: `read_wiki_structure`, `read_wiki_contents`, and `ask_question` with repo `OPCFoundation/UA-.NETStandard`.
## Testing
Use the Client CLI at `src/ZB.MOM.WW.LmxOpcUa.Client.CLI/` for manual testing against the running OPC UA server. Supports connect, read, write, browse, subscribe, historyread, alarms, and redundancy commands. See `docs/Client.CLI.md` for full documentation.
```bash
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
```