Re-ran the 1A gate on the docker-dev rig at e54883a8 after the defect-4 boot
fix. Image rebuilt (otopcua-host:dev -> 1d8452a29018); six host nodes plus
both one-shots recreated; run 1's preserved image was stale and deliberately
not reused. VERDICT: PASS.
Boot: 6/6 nodes healthy INCLUDING the central pair, 0 Hosting failed to start,
/health/ready 200 on every node, MAIN mesh 2/2.
Check 1 PASS: one DispatchDeployment, one correlation id, accepted by all six
nodes; central logs 6 accepted / 0 failed; zero ClusterClient lines on either
central node with Akka.Cluster.Tools.Client at Debug.
Check 2 PASS: deployment Sealed with all six NodeDeploymentState rows Applied
inside ~90 ms, while the four site nodes hold receptionist associations — the
only ack path they have in 1A. Mixed transport proven.
Check 4 PASS: Ack clicked on the real /alerts page against a live ACTIVATED
row; central fanned one AlarmCommand to all six over gRPC and the condition
acknowledged 0.54 s later carrying the operator identity.
Check 7 PASS: with site-b-2's GrpcPort NULLed, both central nodes warned once
and the next dispatch reached exactly five nodes; the deployment then honestly
ended TimedOut with site-b-2 alone unapplied. Row restored, 6/6 sealed after.
Check 8 PASS and no longer vacuous: 0 denials on all four interceptors, and
this time config-serve (28 KB verified artifact fetches from :4055) and
telemetry (streams open on all six, live driver health on /hosts) both carried
real traffic.
Check 3 closed by composition, with the reason now established rather than
assumed: <DriverStatusPanel has 0 usages repo-wide, no rendered page carries a
Restart/Reconnect control, and the only non-script-analysis POST is
/api/deployments. Run 1 drove the node-side leg for both commands; check 4
drives the identical AdminOperationsActor.Dispatch -> DispatchOverGrpc origin
path from the AdminUI.
Checks 5 + 6 stand from run 1 — nothing in the fix touches the interceptor.
New finding 5, recorded because it is load-bearing for the fix's design: the
PreStart resolve LOSES its race on real boots — 2 of 3 observed admin boots
logged Failed to resolve for both dependencies with the same
AuditWriterActorKey cause. The memoize-on-first-use hardening is therefore not
theoretical, and its heal was proven live by moving the coordinator singleton
onto the node that lost the race (stop central-2) and watching central-1 fan a
dispatch to all five live nodes with no dialer error. Residual is cosmetic and
carried to Phase 2: the Error text reads as permanent, and it will trip a soak
error-grep on a healthy node.
Defect 4 marked CLOSED; run 1's record kept in full underneath the combined
table. Rig restored: flip reverted, six nodes healthy on all-ClusterClient on
the committed image, three mesh ClusterClients back on each central node.
OtOpcUa
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
Architecture
OPC UA Clients (CLI, Desktop UI, 3rd-party)
|
v
+-------------------------------------+
| OtOpcUa.Server (.NET 10 AnyCPU) |
| address space + capability fan-out|
+-------------------------------------+
| | | | | | | |
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
|
v
mxaccessgw (sibling repo, gRPC)
|
v
MXAccess COM (x86 worker, on AVEVA box)
Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.
Prerequisites
- .NET 10 SDK (server, drivers, clients all target .NET 10)
- SQL Server reachable for the central config DB
- For Galaxy specifically: a running
mxaccessgwdeployment — see docs/v2/Galaxy.ParityRig.md - For historian read-back / alarm history / continuous historization: a running
ZB.MOM.WW.HistorianGatewaydeployment (the sole historian backend; consumed as theZB.MOM.WW.HistorianGateway.ClientgRPC package). It must runRuntimeDb:Enabled=true+RuntimeDb:EventReadsEnabled=true, and the API key must carryhistorian:read+historian:write+historian:tags:writescopes.
Quick Start
dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx
# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host
The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.
Install as Windows Services
Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.
.\scripts\install\Install-Services.ps1 `
-InstallRoot 'C:\Program Files\OtOpcUa' `
-ServiceAccount 'DOMAIN\svc-otopcua'
The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.
Client CLI
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
See docs/Client.CLI.md and docs/Client.UI.md.
Documentation
Architecture deep-dives
| Topic | Doc |
|---|---|
| OPC UA server composition, namespace fan-out, Polly invoker | docs/OpcUaServer.md |
| Address space layout | docs/AddressSpace.md |
| Read / Write dispatch (driver vs virtual vs scripted-alarm) | docs/ReadWriteOperations.md |
| Incremental sync (driver-backend rediscovery + config publishes) | docs/IncrementalSync.md |
| Service hosting (Server + Admin; external HistorianGateway backend) | docs/ServiceHosting.md |
| Security (transport, LDAP, certificates) | docs/security.md |
| Redundancy | docs/Redundancy.md |
| Status dashboard | docs/StatusDashboard.md |
Drivers
| Topic | Doc |
|---|---|
| Driver specs (per-driver capability surface, config, addressing) | docs/v2/driver-specs.md |
| Galaxy driver | docs/drivers/Galaxy.md |
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT | docs/drivers/ |
| Galaxy parity rig (mxaccessgw setup) | docs/v2/Galaxy.ParityRig.md |
| Galaxy performance + tracing | docs/v2/Galaxy.Performance.md |
Clients
| Topic | Doc |
|---|---|
| Client CLI | docs/Client.CLI.md |
| Client UI (Avalonia desktop) | docs/Client.UI.md |
v1 archive
The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.
License
Internal use only.