Joseph Doherty 2fc1b488fe docs(focas): record the wire decode corrections ported from the ignitionoee driver
FOCAS.md: positions scale from each block's own base/exponent and
PositionDecimalPlaces is only the scale-less fallback; cnc_getfigure is gone;
Spindle Load/MotorSpeedPct are Float64 percentages (MaxRpm renamed); program
fields the CNC does not report read BadNoData; the #548 Makino 'AA' duplicates
were a 2-byte name decode (now AA6/AA7). New 'Wire decode corrections (2026-10)'
table lists each before/after with client-visible changes flagged, plus what
was deliberately not ported and why. Troubleshooting rows for BadNoData and
integer-macro BadTypeMismatch. Test-fixture doc follows the mock changes.
2026-10-07 14:13:00 -04:00

379 lines
22 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# FOCAS Driver
Getting-started guide for the FANUC FOCAS2 driver. This is the short path — for
the exhaustive per-node mapping read [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md),
for the test-harness map read [FOCAS-Test-Fixture.md](FOCAS-Test-Fixture.md).
## What it talks to
FANUC CNCs (0i-D / 0i-F / 0i-MF / 0i-TF / 16i / 30i / 31i / 32i / Power Motion i)
over the proprietary FOCAS2 protocol on TCP port 8193. The wire is spoken
directly by the pure-managed [`Focas.Wire`](https://github.com/Ladder99/focas-mock)
client — no Fwlib64.dll, no P/Invoke, no out-of-process isolation needed.
OtOpcUa is **read-only** against FOCAS; all reads go over the native wire
protocol using the documented command IDs. Writes return
`BadNotWritable` by design.
> **Equipment tags are forced read-only (R2-11, migration note).** The equipment-tag parser
> (`FocasEquipmentTagParser`) now hard-codes `Writable: false` regardless of any authored
> `"writable": true` — previously such a tag advertised a writable node whose write always failed at
> the wire with `BadNotWritable`; now it fails one step earlier at the driver seam (same family of Bad
> status, no successful operation changes). The AdminUI FOCAS editor shows the Writable checkbox
> disabled/unchecked, and the deploy gate warns when a config requests `writable:true`. Additionally,
> equipment-tag references now run the same capability-matrix pre-flight authored tags get: a reference
> whose address violates the device series' matrix fails to resolve (`BadNodeIdUnknown`) instead of
> reaching the wire. Honour `writable` here once PMC writes ship in the wire client.
> **PDU version (v3 / FANUC 30i/31i).** The wire client **accepts inbound PDU versions `{1, 3}`**
> (`FocasWireProtocol`) while still emitting v1 on requests. Older controls + the docker mock answer
> v1; modern controls (Makino Pro 5 / FANUC **31i-B**) answer v3. **Validated live against a real
> 31i-B (`10.201.31.5`) 2026-06-25:** sysinfo, axis/spindle names, dynamic positions/feed/spindle,
> program/mode, **macros**, **timers** (8-byte payload is little-endian {minute, msec}), **PMC range**
> (request widened to the data-type byte width), **servo meters** (8-byte LOADELM stride + names from
> the 0x0089 block), and **alarms** all read correctly. Several *decode* errors that survived that
> validation (because they decode without failing — just wrongly) were later corrected from the
> sister ignitionoee driver's live work on the same family of controls; see
> [Wire decode corrections (2026-10)](#wire-decode-corrections-2026-10). The driver `cnc_rddynamic2` poll is 1-based. **`cnc_rdparam` is unsupported on this
> control** — every request-framing variant returns `EW_FUNC` (likely a wrong v3 command id; needs a
> reference FWLIB trace). The Test-Connect probe now runs a real wire session (initiate + cnc_statinfo)
> instead of a bare TCP check. Full finding, captured wire bytes, validation results, and analysis:
> [`docs/plans/2026-06-25-focas-pdu-v3-30i-b-support.md`](../plans/2026-06-25-focas-pdu-v3-30i-b-support.md)
> + [`…-implementation-plan.md`](../plans/2026-06-25-focas-pdu-v3-implementation-plan.md).
> Capture tools: `scripts/focas/capture-initiate.py`, `scripts/focas/capture-v3.py`.
## Project split
| Project | Target | Role |
|---------|--------|------|
| `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS/` | net10.0 | In-process driver — hosts `WireFocasClient` which speaks FOCAS2 over TCP directly |
Previous `Driver.FOCAS.Host` / `Driver.FOCAS.Shared` Tier-C split has been
retired — the managed wire client removes the native-crash blast radius
that justified the out-of-process service.
## Minimum deployment
Register the driver instance in the main server's `appsettings.json`. No
separate service, no DLL deployment, no shared-secret handshake:
```jsonc
"Drivers": {
"focas-cnc-1": {
"Type": "FOCAS",
"Config": {
"Backend": "wire",
"Devices": [
{ "HostAddress": "focas://10.20.30.40:8193", "Series": "ThirtyOne_i" }
],
"Tags": [
{ "Name": "Mode", "DeviceHostAddress": "focas://10.20.30.40:8193",
"Address": "PARAM:3402", "DataType": "Int32", "Writable": false },
{ "Name": "SpndLoad", "DeviceHostAddress": "focas://10.20.30.40:8193",
"Address": "MACRO:500", "DataType": "Float64", "Writable": false }
]
}
}
}
```
The main server opens two TCP sockets per configured device and speaks the
FOCAS2 binary protocol directly. No local privileged components, no
platform bitness constraint — the driver runs on every host OtOpcUa runs
on.
## Address forms
| Form | Example | Meaning |
|------|---------|---------|
| `X0.0` / `R100` / `R100.3` | PMC bit or byte | Letter + number; optional `.bit` for bit access |
| `PARAM:1815` / `PARAM:1815/0` | CNC parameter | Number + optional axis index |
| `MACRO:500` | Custom macro variable | System / user macro variable number |
| `FIXED:Identity/SeriesNumber` | Fixed-tree field | A path into the [fixed node tree](#fixed-node-tree) — read-only |
The first three name a location the driver asks the CNC for on demand.
`FIXED:` does not: it names a field of the per-device fixed-tree snapshot the
driver's own poll loop already maintains, so a `FIXED:` read issues no wire
traffic. It exists because the fixed tree is the only part of the FOCAS surface
with no address of its own, and v3 publishes nodes only for authored tags — so
without a form to author, the fixed tree could not be published at all.
**An address never carries the device.** A tag's device comes from its raw-tag
Device row; an address that also named a host would be a second, conflicting
routing channel. This is worth stating because it is exactly what went wrong in
[#540](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/540): browse leaves
advertised `{deviceHost}/{path}` as their reference, the browse-commit wrote that
into the address, and every committed tag read `BadNodeIdUnknown` forever.
Addresses are validated against the per-device `Series` at `InitializeAsync` —
a config referencing a number outside the documented range for that series
fails at load time with an error message naming the limit. See
[`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) for the
authoritative range table. (`FIXED:` paths have no numeric range to check; a
path the machine does not expose reads `BadNodeIdUnknown`.)
An address the parser cannot read is rejected **when you author it** — by the
`/raw` tag modal, and by the deploy-time inspector for config arriving via CSV
import or the API. It is not a warning you can deploy past into a driver that
skips the tag at startup.
## Backend selection
The driver picks its client from `Config.Backend`:
| Value | Client | Use it for |
|-------|--------|------------|
| `wire` (default) | `WireFocasClient` | Production — pure-managed FOCAS2 over TCP |
| `unimplemented` / `none` / `stub` | `UnimplementedFocasClientFactory` | Scaffolding a DriverInstance row before the CNC endpoint is reachable |
**Fail-fast on `unimplemented` / `none` / `stub`:** a driver instance configured with any of
these backends now **faults immediately at `InitializeAsync`** with a clear error message rather
than reporting healthy and then failing on the first read/write/subscribe. The driver moves to
`Faulted` state and the error is visible on the Admin UI driver-status panel. This is intentional
— an operator who forgets to switch to `"wire"` before deploying to production sees a driver
fault at startup, not a phantom-healthy driver that silently rejects every request.
Previous backends (`fwlib`, `fwlib32`, `ipc`) have been retired along
with `Driver.FOCAS.Host` and the Fwlib P/Invoke path. Configs that still
reference them will throw at startup with a message pointing here.
## Capability surface
| Capability | Wire path | Notes |
|------------|-----------|-------|
| `IReadable` | `ReadAsync` → `cnc_rdpmcrng` / `cnc_rdparam` / `cnc_rdmacro` | One TCP request/response per read; `Focas.Wire` serializes requests on socket 2 internally |
| `IWritable` | returns `BadNotWritable` | OtOpcUa is read-only against FOCAS by design — no `cnc_wrparam` / `pmc_wrpmcrng` / `cnc_wrmacro` path is implemented |
| `ITagDiscovery` | `DiscoverAsync` | Emits `FOCAS/{device}/{tag}` folders per configured device |
| `ISubscribable` | polled via shared `PollGroupEngine` | FOCAS has no push model — subscriptions turn into per-tag polling groups |
| `IHostConnectivityProbe` | periodic `cnc_rdcncstat` | Probe cadence is `Probe.Interval`; transitions fire `OnHostStatusChanged` |
| `IPerCallHostResolver` | lookup in `_tagsByName` | Each call routes to the device of the referenced tag |
| `IAlarmSource` | polled `cnc_rdalmmsg2` via `FocasAlarmProjection` | Opt-in — set `AlarmProjection.Enabled=true`; diffs `(AlarmNumber, Type)` between ticks |
Ack is a no-op — FANUC clears alarms on its own once the underlying condition
resolves, so `AcknowledgeAsync` swallows the batch rather than surfacing
`BadNotSupported`.
## Fixed node tree
Enable a pre-defined hierarchy of CNC nodes populated automatically from
`cnc_sysinfo` + `cnc_rdaxisname` + `cnc_rddynamic2` + related FWLIB calls,
so operators get an out-of-the-box view of identity / axes / program /
timers without declaring per-address tags.
```jsonc
"Config": {
"Devices": [ ... ],
"Tags": [ ... ],
"FixedTree": {
"Enabled": true,
"PollInterval": "00:00:00.250", // fast — per-axis dynamic reads
"ProgramPollInterval": "00:00:01", // medium — program + mode changes
"TimerPollInterval": "00:00:30" // slow — cumulative counters
}
}
```
`Enabled` defaults to **false** so an upgrade does not grow nodes on configs
that never asked for them. You do not have to set it to use the tree: **authoring
any `FIXED:` tag arms the poll loop by itself**, because committing those tags
already says you want it. The flag remains the way to publish the tree without
authoring anything (and the browser turns it on for the duration of a browse).
### Authoring fixed-tree tags
Browse the device (`/raw` → device → **Browse device…**, or the tag modal's
**Browse machine**) and commit the leaves you want. Each leaf carries its own
`FIXED:` address, so the commit produces working tags with no editing. The
manual composer next to the browser covers PMC / `PARAM:` / `MACRO:` only —
fixed-tree paths are discovered from the machine, not composed from parts.
Two caveats worth knowing before you browse:
- **A CNC that reports duplicate sibling names is disambiguated automatically**
(#548): every member of a collision set gets a 1-based occurrence suffix in slot
order (`Axes/AA_1/`, `Axes/AA_2/`), each reading its own axis, while unique names
stay bare (`Axes/Y/`). ⚠️ The Makino that motivated #548 does **not** in fact
report duplicates — its axes are `AA6` and `AA7`, and the wire layer used to read
only 2 of each 4-byte name record. Since the name-record fix those axes publish as
`Axes/AA6/` and `Axes/AA7/`; tags committed against `Axes/AA_1/…` / `Axes/AA_2/…`
on such a machine must be re-browsed and re-committed. The bare name of a duplicate
set deliberately does not resolve: a tag authored against `Axes/AA/…` on such
a machine reads `BadNodeIdUnknown` rather than one arbitrary axis's data. The
suffix counts occurrences of the *same* name, so adding an unrelated axis
never renames an existing pair — but if the collision-set membership itself
changes (a third `AA` appears, or one of two is removed), the segments change
on the next browse, and previously committed tags on the old segments read Bad
until re-committed. The same rule covers spindles.
- **Values are dated from the last answered poll, not from the read.** If a CNC
stops answering, its fixed-tree values go `BadCommunicationError` rather than
continuing to serve the last snapshot as `Good`; the budget is eight poll
cadences, floored at 30 s.
What gets populated (all under `FOCAS/{deviceHostAddress}/`, addressed as
`FIXED:{subtree}/{field}`):
| Subtree | Nodes | Source call |
|---------|-------|-------------|
| `Identity/` | `SeriesNumber`, `Version`, `MaxAxes`, `CncType`, `MtType`, `AxisCount` | `cnc_sysinfo` once at bootstrap |
| `Axes/{name}/` | `AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`, `ServoLoad` — one folder per discovered axis | `cnc_rdaxisname` once + `cnc_rddynamic2` + `cnc_rdsvmeter` per tick |
| `Axes/FeedRate/Actual`, `Axes/SpindleSpeed/Actual` | Current feed + spindle RPM | `cnc_rddynamic2` |
| `Spindle/{name}/` | `Load` (Float64, % of rated load), `MotorSpeedPct` (Float64, % of maximum speed) — one folder per discovered spindle | `cnc_rdspdlname` once + `cnc_rdspmeter` type 0 + type 1 per tick |
| `Program/` | `Name` (filename), `ONumber`, `Number`, `MainNumber`, `Sequence`, `BlockCount` — a field the CNC did not report (refused sub-read, payload without an O-number) reads `BadNoData`, never `0` | `cnc_exeprgname2` + `cnc_rdblkcount` + cached `cnc_rddynamic2` |
| `OperationMode/` | `Mode` (int), `ModeText` ("AUTO", "MDI", "EDIT", …) | `cnc_rdopmode` |
| `Timers/` | `PowerOnSeconds`, `OperatingSeconds`, `CuttingSeconds`, `CycleSeconds` | `cnc_rdtimer` × 4 |
### Per-series node suppression
The driver probes each optional call once at bootstrap. If the target CNC
returns `EW_FUNC` / `EW_NOOPT` / `EW_VERSION` on the wire, the
corresponding subtree is **not emitted** — the operator doesn't see nodes
that will only ever return `BadDeviceFailure`. Capability suppression
covers `Spindle/`, `Program/` + `OperationMode/`, `Timers/`, and
per-axis `ServoLoad` independently. Identity + `Axes/*` position reads
(which every Fanuc CNC supports) are always emitted.
Position values (`AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`)
are published as `Float64` in engineering units. **Each `cnc_rddynamic2` position block carries
its own scale** — `[i32 raw][u16 base][u16 exponent]`, value = `raw / base^exponent` (a real
31i-B reports base 10 / exponent 4: `2801574` → `280.1574` mm) — and the driver always applies
it. A block that describes no usable position (the `0xFFFF` vacant-slot marker, a base other
than 2 or 10, an exponent > 18) publishes `BadNoData` on that node alone.
`PositionDecimalPlaces` (per device, default `0`) is now only the **fallback for a block that
carries no scale** (a 4-byte payload, e.g. an older simulator): such a position is divided by
`10^PositionDecimalPlaces`. Negative values are clamped to `0`.
```jsonc
"Devices": [
{
"HostAddress": "focas://10.20.30.40:8193",
"Series": "ThirtyOne_i",
"PositionDecimalPlaces": 3 // only used if the CNC's blocks carry no scale
}
]
```
There is no `cnc_getfigure` read: the `0x00D3` command the driver used to send is not a FOCAS
wire command (a real 31i-B refuses it with `rc=1`), so on hardware every axis had silently
fallen back to `PositionDecimalPlaces` and published raw counts.
**Still hand-authored**: `PARAM:6711`, `MACRO:500`, `R100` etc. — specific
numbers whose meaning is MTB-specific, and which no browse can discover. Those
go under the device folder alongside the fixed subtree.
## Alarm projection
Alarm surfacing is **disabled by default** because the polling cost is wasted
on sites that don't consume CNC alarms. Opt in per driver instance:
```jsonc
"Config": {
"Devices": [ ... ],
"Tags": [ ... ],
"AlarmProjection": {
"Enabled": true,
"PollInterval": "00:00:02"
}
}
```
Every alarm transition fires `OnAlarmEvent` with:
- `SourceNodeId` = the device host address (FOCAS has no per-node alarm model;
the CNC exposes a single flat active-alarm list per session)
- `ConditionId` = `"{host}#{Type}:{AlarmNumber}"`
- `AlarmType` = projected from FANUC's `ALM_TYPE_*` (e.g. `Overtravel`, `Servo`,
`Parameter`, `MacroAlarm`)
- `Severity` = Overtravel / Servo / PulseCode → `Critical`; Parameter / Macro
→ `Medium`; everything else → `High`
Cleared alarms fire a second event with `" (cleared)"` appended to the message
so downstream consumers can ignore the clear if they only care about raises.
## Handle recycling
FANUC CNCs have a finite FWLIB handle pool (~5–10 concurrent connections) and
certain series have documented handle-leak bugs that manifest after long uptime.
The driver can proactively close + reopen each device's session on a cadence to
release its slot back to the pool:
```jsonc
"Config": {
"Devices": [ ... ],
"HandleRecycle": {
"Enabled": true,
"Interval": "01:00:00"
}
}
```
Disabled by default — a healthy CNC + driver doesn't need it. Enable when field
experience shows handle exhaustion. Typical tuning: 30 min for sites running
multiple OtOpcUa instances against the same CNC (they share the pool); 6 h for a
single-client deployment. Reads / writes during recycle simply wait for the
reconnect rather than failing — worst case, an operator sees a brief read
latency spike once per cadence.
## Testing
- **Unit tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests/` cover the
driver surface via `FakeFocasClient`. Includes the alarm-projection raise /
clear diffing tests.
- **Integration tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.IntegrationTests/`
hold the Docker simulator scaffold; see
[`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md)
for what the simulator emits vs. real CNC behaviour.
- **E2E script** — `scripts/e2e/test-focas.ps1` stages Host + Proxy + a real
CNC (or the simulator) and exercises connect → read → write → subscribe
round-trips. See [`docs/drivers/FOCAS-Test-Fixture.md`](FOCAS-Test-Fixture.md)
for the coverage map.
## Troubleshooting
| Symptom | Likely cause | Fix |
|---------|--------------|-----|
| Driver faults immediately at startup with "unimplemented" in the error | `Backend` is `"unimplemented"` / `"none"` / `"stub"` | Change `Backend` to `"wire"` and supply the real CNC endpoint in `Devices[]` |
| `BadCommunicationError` on every read | CNC unreachable on TCP:8193 | Check firewall / LAN reachability; FOCAS Ethernet option must be licensed on the CNC side |
| Every read returns `BadNotWritable` on writes | Expected — OtOpcUa is read-only against FOCAS | If you actually need writes, open a feature request — the driver's managed wire client doesn't expose the write commands |
| `BadOutOfRange` on reads for a macro/parameter | Config address outside the declared `Series` range | Check `docs/v2/focas-version-matrix.md` — either fix the address or widen the `Series` |
| Alarm events never fire | `AlarmProjection.Enabled` left at default (false) | Set it to `true` in the driver config |
| Axis position values seem 1000× too large | The CNC's position blocks carry no scale (older control / simulator) and `PositionDecimalPlaces` is not set | Add `"PositionDecimalPlaces": 3` (or the MTB-specific value) to the device entry in `Devices[]`. A real 30i/31i carries the scale in each block and needs no setting |
| A fixed-tree node or `MACRO:` tag reads `BadNoData` | The CNC answered but described no value — a vacant macro variable, an undescribable position/meter record, a program field it did not report | Check the address on the control; this is the control's answer, not a comms fault |
| An integer-typed `MACRO:` tag reads `BadTypeMismatch` | The macro holds a fractional value (e.g. `148.5`) | Author the tag as `Float64`, or point it at a whole-valued variable — a fraction is never truncated into an integer tag |
## Wire decode corrections (2026-10)
Each of these decoded without ever failing — just wrongly — so live validation that only checked
"the read succeeds" passed them. All were found by the sister **ignitionoee** FOCAS driver
against a real Makino 31i-B (Z-34184, series G431) and ported here with its captured payloads as
test fixtures (`tests/.../Driver.FOCAS.Tests/Fixtures/v3/`). Client-visible changes are marked ⚠️.
| What | Before | Now |
|------|--------|-----|
| `cnc_rdmacro` decimal | read at payload offset 4 — a constant `10` length field — so `#500 = 1.0` published `0.01` | `dec_val` at offset 6; `mantissa / 10^dec`. Vacant variable → `BadNoData`; fractional value on an integer tag → `BadTypeMismatch`; integer tags receive the exact whole value |
| Axis positions | scaled by `cnc_getfigure` (0x00D3), which does not exist — on hardware: raw counts | scaled by each block's own `base^exponent`; undescribable block → `BadNoData` |
| Axis / spindle names | first 2 of 4 record bytes — `AA6`/`AA7` collapsed to `AA` | whole record up to the first NUL (residue after it discarded) — ⚠️ `Axes/AA_1`→`Axes/AA6` on such a machine |
| `ServoLoad` | `value / 10^base` (offset 4 is the base, 10) — always ~0 | `value / base^exponent`, a direct percentage |
| `Spindle/{n}/Load` | raw meter count, Int32 (`9155`) | ⚠️ Float64 % of rated load (`55.9`): the meter is a 1/16384 fraction of full scale |
| `Spindle/{n}/MaxRpm` | the type-1 meter read once at bootstrap and served as a "max RPM" | ⚠️ **renamed `MotorSpeedPct`**, Float64 % of maximum speed, polled every tick |
| Program `ONumber` / `Name` / `BlockCount` / `Mode` | defaulted to `0` / `""` when not reported (Mode `0` = MDI) | `BadNoData` |
Not ported (and why): the ignitionoee `RunState` run-word decode and fault debounce (this driver
publishes no run-state — `cnc_statinfo` is used only as the connectivity probe); `cnc_rdparam3`
(0x008D) and its echo guard (this driver never sends 0x008D — the real 31i-B answers it with
264-byte records that are not a parameter read); the IODBPSD-offset and Fanuc-real `FLOAT`
re-interpretation of `cnc_rdparam` (no successful `cnc_rdparam` capture exists on either side —
the reference 31i-B refuses it with `EW_FUNC`, which already reads `BadNotSupported` here); and
the all-axes multi-block `cnc_rddynamic2` batching (a latency optimisation, not a correctness fix).
## Further reading
- [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md) — full OPC UA node
mapping, pre-defined tag set, per-API notes
- [`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) —
per-series macro / parameter / PMC range table
- [`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md)
— captured FOCAS2 wire semantics (magic prefix, handshake, command-id table)
- [upstream `Focas.Wire`](https://github.com/Ladder99/focas-mock/tree/main/dotnet/Focas.Wire)
— the managed client implementation OtOpcUa consumes as a NuGet dependency