T
Joseph Doherty 1891f5d6a7 docs(archreview): 2026-07-12 re-review at f6eaa267 + 12 round-2 remediation plans
Re-ran all seven domain reviews at master f6eaa267 (reports rewritten in
place, each with a prior-finding status table): all 4 round-1 Criticals
verified closed; new top findings are the S7 connect-timeout OCE regression
(05/STAB-14), the ResilienceConfig operator-authorable brick (01/S-6), and
a batch of resilience-seam Mediums. 00-OVERALL.md carries the updated
maturity matrix + 12-item action list.

Adds R2-01..R2-12 design/implementation plans (one per action item, house
format + bite-sized TDD task breakdowns + co-located .tasks.json; 193 tasks,
~18-24 dev-days). STATUS.md updated: round-1 topology marked historical
(all merged+pushed), re-review findings table + plan pointers added.
2026-07-12 23:52:23 -04:00

733 lines
46 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Design + Implementation Plan — R2-01 S7 Fault-Path Hardening
**Source report:** `archreview/05-protocol-drivers.md` (2026-07-12 re-review)
**Plan verified against tree at:** `f6eaa267` (master, clean)
**Scope:** `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/` (`S7Driver.cs`, `IS7Plc.cs`) + `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/` + `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/`
**Action-list item:** #1 in `archreview/00-OVERALL.md` — "S7: filter connect-timeout OCE in the ensure-wrapper + poll-loop catches; broaden fatal classification (framing/cancel); mark handle dead in probe catch. Add fake-factory connect-timeout test" (05/STAB-14 + 05/STAB-15; STAB-8's S7 seam noted for R2-09).
> Both findings are residuals of the Critical-3 fix (`25c0c6f6`, round-1 plan §A1/STAB-1,
> `archreview/plans/05-protocol-drivers-plan.md`). STAB-14 is a **regression inside that fix** —
> it re-opens the exact scenario class (transient outage permanently kills S7 subscriptions)
> that Critical 3 was merged to close, just via connect-*timeout* instead of no-reconnect.
> Modbus's twin defect (STAB-3, same desync class as STAB-15) is **out of scope** here — the
> report's remediation order pairs it with STAB-15 conceptually, but it lives in
> `ModbusTcpTransport.cs` and is tracked separately.
---
## Verification summary
Every cited line was opened at `f6eaa267`. **Both findings CONFIRMED. Three citations drifted
by ≤6 lines** (the report was written against the same commit but a few ranges anchor on doc
comments rather than code); corrected refs below are used throughout this plan.
| Report citation | Status at `f6eaa267` | Corrected ref |
|---|---|---|
| STAB-14 — `S7Driver.cs:488` ensure-wrapper `catch (OperationCanceledException) { throw; }` in `ReadAsync` | **CONFIRMED exact** — unconditional rethrow, no `when` filter | `:488` |
| STAB-14 — `S7Driver.cs:1000` same wrapper in `WriteAsync` | **CONFIRMED exact** | `:1000` |
| STAB-14 — `S7Driver.cs:1383, 1404` `PollLoopAsync` bare `catch (OperationCanceledException) { return; }` | **CONFIRMED exact** (initial-read catch `:1383`, tick catch `:1404`; the `Task.Delay` catch at `:1396-1397` is a third bare OCE-return) | `:1383, :1396-1397, :1404` |
| STAB-14 — `S7Driver.cs:1206-1208` linked `CancelAfter(_options.Timeout)` in `EnsureConnectedAsync` | **CONFIRMED, drifted 2** — the `using var cts` / `CancelAfter` / `OpenAsync(cts.Token)` block is at `:1204-1206`; method spans `:1187-1218` | `:1204-1206` |
| STAB-15 — `S7Driver.cs:1239-1251` `IsS7ConnectionFatal` | **CONFIRMED, drifted +1..3** — the cited range starts inside the xmldoc; the method body is `:1242-1252` (`MarkConnectionDeadIfFatal` at `:1226-1229`). Classifies only `SocketException`/`IOException`/`ObjectDisposedException` (inner-walking) + `PlcException{ErrorCode.ConnectionError}` — no framing types, no cancellation | `:1242-1252` |
| STAB-15 — `S7Driver.cs:1542` probe bare `catch { }` never marks dead | **CONFIRMED exact**`catch { /* transport/timeout/exception — treated as Stopped below */ }`; no `MarkConnectionDeadIfFatal` anywhere in `ProbeLoopAsync` (`:1516-1549`) | `:1542` |
| STAB-8 (S7 part) — `S7Driver.cs:1188-1224` unthrottled per-call reconnect | **CONFIRMED, drifted**`EnsureConnectedAsync` is `:1187-1218`; no attempt throttle, full `OpenAsync` bounded only by `_options.Timeout` per data call/probe tick while the PLC is down | `:1187-1218` |
Additional load-bearing facts verified for the design:
- **`ReadAsync` per-item loop swallows OCE today** — there is no per-item OCE catch; a mid-PDU
cancellation falls into `catch (Exception ex)` (`S7Driver.cs:536-543`) → `MarkConnectionDeadIfFatal`
(a no-op for OCE) → `BadCommunicationError`, and the half-read socket is **kept**. `WriteAsync`'s
per-item loop *does* have an explicit OCE catch (`:1043-1048`) that rethrows — also without
marking the handle dead. Both are STAB-15(b) sites.
- **The driver throws its own `System.IO.InvalidDataException`** as the decode type-mismatch
backstop in `ReinterpretRawValue` (`S7Driver.cs:973-975`) — a *config* fault on a healthy
socket. This constrains the classifier design (below): blanket-classifying
`InvalidDataException` as connection-fatal would churn a reopen on every read of a
mis-authored tag.
- **S7.Net 0.20.0 framing surface** (verified against the shipped assembly,
`~/.nuget/packages/s7netplus/0.20.0`): `TPKTInvalidException`, `TPDUInvalidException`,
`WrongNumberOfBytesException` are `public` classes with public parameterless ctors (directly
constructible in tests), plus `PlcException` with `ErrorCode.WrongNumberReceivedBytes`. None
are classified fatal today.
- **The probe's own OCE handling is already correct for STAB-14** — `:1541`
`catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }` filters on
the loop token, so a probe-*timeout* OCE falls to the bare catch and reads as `Stopped`. Its
only gap is STAB-15(b): the bare catch never marks the handle dead.
- **`InitializeAsync` has the same unfiltered connect pattern** (`:186-196`): a connect-timeout
OCE escapes to the outer `catch (Exception ex)``Faulted` + rethrow — the *health* outcome is
right, but the caller receives an OCE for what is a connection failure. Included as a
consistency fix (low stakes; init callers treat any throw as init failure).
- **Test infra:** `S7DriverReconnectTests` (`tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`)
holds the private `FakeS7PlcFactory`/`FakeS7Plc` (Options: `Timeout = 250ms`, probe disabled).
`InternalsVisibleTo("ZB.MOM.WW.OtOpcUa.Driver.S7.Tests")` is in place
(`ZB.MOM.WW.OtOpcUa.Driver.S7.csproj:26`). The live suite `S7_1500ReconnectTests` is
double-gated on `Snap7ServerFixture` + `S7_RECONNECT_BOUNCE_CMD` and — as the report says —
**structurally blind to STAB-14**: `docker restart` yields connection-*refused*
(`SocketException`, immediate), never the SYN-blackhole connect-*timeout* the bug needs.
---
## Finding 1 — STAB-14 (High, regression) — connect-timeout OCE permanently kills S7 subscription polls
**Restatement.** `EnsureConnectedAsync` bounds the reopen with a linked
`CancelAfter(_options.Timeout)` CTS (`S7Driver.cs:1204-1206`). Against an
unreachable-but-not-refusing host (pulled cable, powered-off PLC on a switched network,
firewall DROP — the classic field outage Critical 3 targeted), `OpenAsync` throws
`TaskCanceledException` when that internal timer fires. The read/write ensure-wrappers rethrow
*any* OCE unconditionally (`:488`, `:1000`), so the timeout escapes the driver as OCE. In the
poll loop, `catch (OperationCanceledException) { return; }` (`:1383`, `:1404`) treats every OCE
as teardown and exits — no log, no health change, no `HandlePollFailure`. Server-initiated
reads/writes self-heal on the next call (the Critical-3 fix working as designed), but **every
subscription poll loop that ticks during the outage is silently and permanently dead until
redeploy**.
**Verification.** Confirmed at the corrected refs above. Traced end-to-end: poll tick →
`PollOnceAsync` (`:1458`) → internal `ReadAsync` with the loop's `ct``_gate`
`EnsureConnectedAsync` → hang → internal `cts.CancelAfter` fires → `TaskCanceledException`
(an OCE) → wrapper `:488` rethrows (the caller's `ct` is **not** cancelled) → `PollLoopAsync`
tick catch `:1404``return`. Nothing distinguishes this from teardown. Also confirmed the unit
suite can't currently see it: `FakeS7Plc.OpenAsync` never honours its token (returns
synchronously or `Task.FromException`), so no existing test produces a timeout-OCE from open.
**Root cause.** The Critical-3 fix introduced an *internal* timeout implemented as cancellation
(`CancelAfter` on a linked CTS) but let the resulting OCE escape with caller-cancellation
semantics. Downstream, the bespoke poll loop's bare OCE-catch (a CONV-1 fork divergence —
`PollGroupEngine` never had this shape) turned "one timed-out reconnect attempt" into "loop
exits forever". Two mistakes compound: timeout encoded as OCE at the source, and OCE interpreted
as teardown without consulting the loop token.
**Proposed design.** Fix at **three layers** — the source plus two defensive filters — so no
single future edit can reintroduce the class:
1. **Source conversion (the root fix):** in `EnsureConnectedAsync`, catch the internal-timeout
OCE and rethrow it as `TimeoutException`. A connect timeout *is* a connection failure, not a
cancellation; converting at the source makes every caller (read wrapper, write wrapper,
probe) handle it via their existing generic degrade paths with zero further changes, and puts
a meaningful message in the logs/`_health.LastError` instead of "operation was canceled".
2. **Wrapper filters (belt):** `:488` and `:1000` become
`catch (OperationCanceledException) when (cancellationToken.IsCancellationRequested) { throw; }`
caller cancellation still propagates; any *other* OCE (should no longer occur after #1, but
e.g. an S7.Net-internal CTS in a future package bump) falls through to the existing
`catch (Exception ex)` → whole-batch `BadCommunicationError` + `Degraded`.
3. **Poll-loop filters (suspenders):** `:1383`, `:1396-1397`, `:1404` become
`catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }`. A
non-teardown OCE at `:1383`/`:1404` then falls into the existing `catch (Exception ex)`
`HandlePollFailure` (log + Degraded + capped backoff) — the loop lives. (The `Task.Delay`
catch at `:1396-1397` can only see `ct`-triggered OCE, so its filter is purely for uniformity.)
4. **Consistency:** apply the same timeout→`TimeoutException` conversion to the identical
connect block in `InitializeAsync` (`:186-196`), so init-time and reconnect-time timeouts
surface the same exception type.
*Alternatives considered:*
- **`when` filters only, no source conversion** (the report's literal recommendation). Works,
but leaves "timeout = OCE" encoded in the driver's exception contract: every current and
future caller of `EnsureConnectedAsync` must remember the filter idiom (the probe already has
it; a fourth caller wouldn't). Converting at the source fixes the taxonomy once. Rejected as
*sole* fix; kept as layers 2-3 because defense-in-depth here is nearly free and the filters
also cover OCEs born *below* `EnsureConnectedAsync`.
- **Retry inside `EnsureConnectedAsync` on timeout.** Rejected — retry/backoff policy is exactly
the fleet-wide primitive R2-09 owns (STAB-8); baking an ad-hoc retry here would pre-empt it.
- **Move S7 onto `PollGroupEngine` now (CONV-1)** — the fork's OCE handling disappears with the
fork. Right end-state, wrong scope: PollGroupEngine v2 (backoff + onError absorption) is the
report's remediation item #5 and is a multi-driver change. This plan's two-line filters are
the safe immediate stop-loss; they do not conflict with a later migration.
**Implementation steps** (exact code for each small bit):
1. `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs`, `EnsureConnectedAsync` — replace the
`try/catch` around `OpenAsync` (`:1202-1212`) with:
```csharp
try
{
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
cts.CancelAfter(_options.Timeout);
await plc.OpenAsync(cts.Token).ConfigureAwait(false);
}
catch (OperationCanceledException) when (!ct.IsCancellationRequested)
{
// The linked CancelAfter fired — a connect TIMEOUT, not a caller cancellation.
// Surface it as a connection FAILURE (TimeoutException) so callers route it through
// their degrade paths: an escaping OCE reads as teardown and permanently killed the
// subscription poll loops (STAB-14, the unreachable-host regression in the Crit-3 fix).
try { plc.Dispose(); } catch { /* best-effort */ }
throw new TimeoutException(
$"S7 connect to {_options.Host}:{_options.Port} timed out after " +
$"{(int)_options.Timeout.TotalMilliseconds} ms.");
}
catch
{
try { plc.Dispose(); } catch { /* best-effort */ }
throw;
}
```
2. Same file, `ReadAsync` `:488` and `WriteAsync` `:1000` — change
```csharp
catch (OperationCanceledException) { throw; }
```
to
```csharp
// Rethrow ONLY caller cancellation. A timeout-born OCE (none expected after the
// EnsureConnectedAsync conversion, but e.g. an S7.Net-internal CTS) must degrade the
// batch below, not escape as teardown (STAB-14).
catch (OperationCanceledException) when (cancellationToken.IsCancellationRequested) { throw; }
```
3. Same file, `PollLoopAsync` — add `when (ct.IsCancellationRequested)` to the three OCE catches
(`:1383`, `:1396-1397`, `:1404`), e.g. the tick catch:
```csharp
catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }
catch (Exception ex) // now also receives any non-teardown OCE → backoff, not death
{
consecutiveFailures++;
HandlePollFailure(ex, consecutiveFailures, initial: false);
}
```
4. Same file, `InitializeAsync` `:184-196` — mirror step 1's `when (!cancellationToken.IsCancellationRequested)`
→ `TimeoutException` conversion around the initial `OpenAsync`.
**Tests** (all in `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`,
extending the existing fakes — see Task 0; the driver's `Options()` fixture keeps
`Timeout = 250ms` so hang-until-cancelled opens cost 250 ms each):
- **T1 (the mandated first-and-failing regression test)**
`Read_degrades_batch_on_connect_timeout_instead_of_throwing` — connection #1 drops
(`NextReadThrows = PlcException(ConnectionError)` → marks dead), factory set to
hang-until-cancelled opens; the next `ReadAsync` **currently throws `TaskCanceledException`**;
expected: returns a `BadCommunicationError` batch + `Degraded` health, no throw. **FAILS at
`f6eaa267`.**
- **T2** `Subscription_poll_loop_survives_a_connect_timeout_outage_and_recovers` — subscribe at
100 ms; drop the socket; let ≥1 poll tick hit a hanging reconnect
(`OpenHangsUntilCancelledCount = 2`); then restore normal opens; assert a Good `OnDataChange`
arrives *after* a Bad one within a 10 s deadline (`TaskCompletionSource` + `WaitAsync`).
**FAILS at `f6eaa267`** (loop exits on the first timeout tick; no recovery event ever fires).
- **T3** `Write_degrades_batch_on_connect_timeout_instead_of_throwing` — T1's shape through
`WriteAsync`. **FAILS at `f6eaa267`.**
- **T4 (pinning)** `Read_still_propagates_caller_cancellation_during_connect` — options
`Timeout = 5s`, hang-until-cancelled open, caller CTS cancelled after 50 ms; assert
`OperationCanceledException` propagates. **PASSES before and after** — pins the filter
direction so the fix can't over-rotate into swallowing real cancellation.
**Effort:** S. **Risk/blast-radius:** Low. Four small catch-clause edits on one file; the happy
path is untouched. Behavior deltas: (a) connect-timeout now yields `TimeoutException`/Bad-batch
instead of OCE — strictly the documented intent of the Crit-3 degrade path; (b) poll loops
survive timeouts with backoff — the regression closed. Callers seeing `TimeoutException` where
OCE escaped before: only the poll loop (fixed to want this) and `DriverHostActor` dispatch
(treats both as capability failure).
---
## Finding 2 — STAB-15 (High) — fatal classification misses framing/desync + cancellation-during-I/O; probe never marks dead
**Restatement.** `IsS7ConnectionFatal` (`S7Driver.cs:1242-1252`) classifies only
`SocketException`/`IOException`/`ObjectDisposedException` (inner-walking) and
`PlcException{ConnectionError}`. Two gaps: **(a)** a caller-token cancellation mid-PDU (server
request deadline, or a dispatch-layer Polly timeout now that `CapabilityInvoker` wraps driver
calls) abandons a half-read ISO-on-TCP response on the socket; OCE is not classified, the handle
is kept, and the next call reads stale bytes. S7.Net then surfaces framing faults
(`TPKTInvalidException`, `TPDUInvalidException`, `WrongNumberOfBytesException`,
`PlcException{WrongNumberReceivedBytes}`) — none classified fatal either — so the single gated
connection stays **permanently desynchronized** (the Modbus STAB-3 mode rebuilt in S7).
**(b)** The probe loop swallows every failure (`:1542`) without marking the handle dead, so its
reconnect-backstop role only works when `TcpClient.Connected` flips false on its own; a
wire-dead or desynced handle that still claims `Connected` is re-probed and re-fails forever
(contrast TwinCAT's probe, which force-recycles on failure).
**Verification.** Confirmed. `IsS7ConnectionFatal` body at `:1242-1252` matches the report's
description exactly. Read path: no per-item OCE catch — OCE lands in `catch (Exception ex)`
(`:536-543`), `MarkConnectionDeadIfFatal` no-ops, socket kept. Write path: explicit per-item OCE
rethrow at `:1043-1048`, also without marking. Probe: gate-held body `:1529-1539`, teardown OCE
filter `:1541`, bare swallow `:1542`; `MarkConnectionDeadIfFatal` is absent from the whole loop.
S7.Net exception taxonomy verified against the 0.20.0 assembly (all three framing types public,
public parameterless ctors — unit-constructible). One nuance the report under-specifies: the
driver *itself* throws `System.IO.InvalidDataException` for a declared-type/address-size
mismatch (`:973-975`), so the report's suggestion to classify `InvalidDataException` as a
framing fault must be narrowed (see design).
**Root cause.** The Crit-3 classifier was written from S7.Net's *connection-error* surface
(socket-level types + `ConnectionError`) without walking its *framing/parsing* surface, and
without the "cancellation abandons an in-flight PDU on a single serialized stream" insight the
Modbus STAB-3 analysis had already produced. The probe predates the dead-handle flag and was
never taught to feed it.
**Proposed design.**
- **(a1) Broaden the classifier to the framing surface.** Add to the inner-walk of
`IsS7ConnectionFatal`: `TPKTInvalidException`, `TPDUInvalidException`,
`WrongNumberOfBytesException`, and `PlcException{ErrorCode.WrongNumberReceivedBytes}`. A
framing violation on ISO-on-TCP means the stream position is untrustworthy; only a reopen
recovers. **Deliberately NOT `System.IO.InvalidDataException`:** the driver's own decode
backstop (`:973-975`) throws it for a *config* mismatch on a healthy socket — classifying it
would churn a full reopen on every read of a mis-authored tag. Residual risk accepted: if some
S7.Net path signals desync *only* via `InvalidDataException`, the desynced stream's very next
PDU still lands in TPKT/TPDU/WrongNumber territory, which now tears down — self-heal within
one extra failed call.
- **(a2) Cancellation observed during wire I/O marks the handle dead before propagating.** Add a
per-item OCE catch in `ReadAsync`'s loop (`_plcDead = true; throw;`) and add
`_plcDead = true;` to `WriteAsync`'s existing per-item OCE catch (`:1043-1048`). Both run under
`_gate`, honouring `_plcDead`'s documented gate-guarded discipline. Marking is deliberately
*unconditional* on OCE here (not routed through the type classifier): whether any bytes moved
is unknowable from outside, and the worst case of a false positive is one cheap reopen —
versus permanent desync for a false negative. **Behavior change (read path):** caller
cancellation mid-read now propagates as OCE instead of being converted to a
`BadCommunicationError` snapshot — consistent with `WriteAsync`, with the pre-loop
`_gate.WaitAsync(cancellationToken)`, and with "the caller cancelled; nobody consumes the
batch".
- **(b) Probe marks dead under the gate.** Restructure the gate-held probe body with an inner
try/catch so classification happens while `_gate` is still held (keeping `_plcDead`
gate-guarded — the current outer catch sits outside the gate): teardown OCE rethrows to the
outer filter; a probe-*timeout* OCE (deadline fired mid-`ReadStatusAsync` PDU) marks dead
unconditionally (same abandonment argument as (a2)); any other exception goes through
`MarkConnectionDeadIfFatal`. Net effect: a desynced/hung handle whose `TcpClient.Connected`
lies is disposed and reopened by the *next probe tick's* `EnsureConnectedAsync` — the probe
becomes the real backstop the Crit-3 design intended (mirrors TwinCAT's probe-recycle).
*Alternatives considered:*
- **Classify OCE inside `IsS7ConnectionFatal`** instead of at the catch sites — rejected: the
classifier is also called for exceptions that *wrap* an OCE thrown before any I/O, and the
ensure-wrapper OCE (connect timeout) has no live handle to mark; explicit
`_plcDead = true` at the three I/O catch sites is smaller and keeps the classifier a pure
type-taxonomy function.
- **Force-recycle (dispose + null `Plc`) directly in the probe catch** à la TwinCAT — rejected:
S7 already has the exactly-once-dispose discipline centralized in `EnsureConnectedAsync` via
`_plcDead`; a second dispose site would reintroduce the race the flag was built to prevent.
- **Blanket-classify `InvalidDataException`** (report's literal text) — rejected as unsafe for
the reason in (a1); revisit only if the decode backstop at `:973-975` is retyped first.
**Implementation steps:**
1. `S7Driver.cs`, `IsS7ConnectionFatal` (`:1242-1252`) — extend the walk:
```csharp
for (Exception? e = ex; e is not null; e = e.InnerException)
{
if (e is System.Net.Sockets.SocketException or System.IO.IOException or ObjectDisposedException)
return true;
// ISO-on-TCP framing/desync surface (STAB-15a): the stream position is untrustworthy —
// a half-read PDU left by a timeout/cancellation makes every later response mis-frame.
// NOTE: deliberately NOT System.IO.InvalidDataException — ReinterpretRawValue throws it
// for a declared-type/address-size CONFIG mismatch on a healthy socket.
if (e is TPKTInvalidException or TPDUInvalidException or WrongNumberOfBytesException)
return true;
if (e is PlcException { ErrorCode: ErrorCode.ConnectionError or ErrorCode.WrongNumberReceivedBytes })
return true;
}
return false;
```
Update the method's xmldoc to match.
2. `ReadAsync` per-item loop — insert **before** `catch (NotSupportedException)` (`:511`):
```csharp
catch (OperationCanceledException)
{
// Cancellation observed mid-PDU abandons a half-read ISO-on-TCP response on the
// single gated stream — the handle must be reopened, not reused (STAB-15). Mark dead
// (we hold _gate) and propagate: the caller cancelled, nobody consumes the batch.
_plcDead = true;
throw;
}
```
3. `WriteAsync` per-item OCE catch (`:1043-1048`) — add `_plcDead = true;` above the `throw;`
(extend the comment with the same rationale).
4. `ProbeLoopAsync` (`:1516-1549`) — restructure the gate-held section:
```csharp
await _gate.WaitAsync(probeCts.Token).ConfigureAwait(false);
try
{
try
{
var plc = await EnsureConnectedAsync(probeCts.Token).ConfigureAwait(false);
await plc.ReadStatusAsync(probeCts.Token).ConfigureAwait(false);
success = true;
}
catch (OperationCanceledException) when (ct.IsCancellationRequested) { throw; } // teardown → outer filter
catch (OperationCanceledException)
{
// Probe deadline fired mid-PDU: the CPU-status response may still be in flight,
// so the handle can't be reused (half-read ⇒ desync). We hold _gate here.
_plcDead = true;
}
catch (Exception ex)
{
// STAB-15(b): classify + mark while holding _gate so a wire-dead/desynced handle
// whose TcpClient still claims Connected is reopened by the NEXT tick's
// EnsureConnectedAsync instead of being re-probed forever.
MarkConnectionDeadIfFatal(ex);
}
}
finally { _gate.Release(); }
```
The existing outer `catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }`
(`:1541`) and bare `catch { }` (`:1542`) stay — the outer bare catch now handles only
gate-*wait* timeouts (gate contention is not a connection fault; correctly not marked) and the
rethrown teardown OCE exits via the outer filter after `finally` releases the gate.
**Tests** (same file/fakes as Finding 1):
- **T5** `Framing_faults_are_classified_connection_fatal_and_reopen` — `[Theory]` over
`TPKTInvalidException`, `TPDUInvalidException`, `WrongNumberOfBytesException`,
`PlcException(ErrorCode.WrongNumberReceivedBytes)` as `NextReadThrows`; assert the *next* read
opens connection #2 and reads Good (`factory.Created.Count == 2`). **FAILS at `f6eaa267`**
(count stays 1). Companion negative: `PlcException(ErrorCode.ReadData)` still does **not**
reopen (already covered by `Read_does_not_reopen_on_a_data_address_error` — keep green).
- **T6** `Cancelled_read_marks_handle_dead_and_next_read_reopens` — fake read hangs on its token;
caller cancels at 50 ms; assert OCE propagates **and** the next (fresh-token) read creates
connection #2. **FAILS at `f6eaa267`** (OCE → `BadCommunicationError`, same handle reused).
- **T7** `Cancelled_write_marks_handle_dead_and_next_read_reopens` — same via a hanging write
(OCE already propagates today; the reopen assertion is what fails). **FAILS at `f6eaa267`.**
- **T8** `Probe_failure_on_connected_socket_marks_dead_and_next_tick_reopens` — probe enabled
(`Interval = 50ms`, `Timeout = 250ms`); connection #1's `ReadStatusAsync` throws
`SocketException` persistently while `IsConnected` stays true; assert
`factory.Created.Count >= 2` and a `Running` host transition within a bounded window (the
probe's own next tick reopens via `EnsureConnectedAsync`). **FAILS at `f6eaa267`** (fast path
returns the same lying handle forever). Variant in the same test class:
**T9** `Probe_timeout_marks_dead` — `ReadStatusAsync` hangs on its token instead of throwing;
same assertions. **FAILS at `f6eaa267`.**
**Effort:** S-M (the probe restructure is the only non-trivial edit). **Risk/blast-radius:**
Low-Medium, all inside `S7Driver.cs`. Deltas: (a) framing faults now cost one reopen instead of
permanent desync — reopen churn is bounded by the fault actually recurring; (b) read-path caller
cancellation now propagates (contract-consistent; the only in-repo poll-loop caller handles OCE
via the Finding-1 filters); (c) probe can now trigger reopens — bounded to one reopen per failed
probe tick, and only when the failure classifies fatal or times out (a healthy-but-slow PLC that
*answers* within `Probe.Timeout` is unaffected).
---
## Finding 3 — STAB-8, S7-specific part (Medium, note-only here) — unthrottled per-call reconnect; the R2-09 seam
**Restatement.** While the PLC is down, every data call and every probe tick pays a full TCP
connect attempt bounded only by `_options.Timeout` (`EnsureConnectedAsync`, `:1187-1218`) — no
attempt throttle. The poll loop's capped backoff (`:1393-1397`, `ComputeBackoffDelay` `:1447`)
shields subscriptions only; server-initiated reads/writes and the probe retry unthrottled.
**Verification.** Confirmed at the corrected refs (report's `:1188-1224` drifted; method is
`:1187-1218`). Note the Finding-1/2 changes slightly *reduce* dead-PLC cost already: poll ticks
that previously died (stopping their contribution) now back off to `PollBackoffCap` (30 s), and
timeout-OCEs no longer escape as anomalous exceptions.
**Proposed design — no throttle implemented in this plan.** The connect-attempt throttle is a
fleet-wide primitive (S7, AbCip, FOCAS, TwinCAT all need it) and belongs to **R2-09**
(PollGroupEngine v2 / reconnect-backoff consolidation). This plan only **documents the seam**:
`EnsureConnectedAsync` is the single choke-point every S7 reconnect flows through (data calls +
probe), already gate-serialized, so R2-09's throttle is a last-failed-attempt timestamp checked
at the top of its slow path — one field + one early-throw, no structural change. A `<remarks>`
paragraph on `EnsureConnectedAsync` names this so R2-09's implementer (and any interim reader
wondering about dead-PLC connect churn) lands here. *Alternative — implement the throttle now:*
rejected; a driver-local knob would immediately become fleet debt and prejudge R2-09's shape
(shared policy vs per-driver options).
**Implementation steps:** extend the `EnsureConnectedAsync` xmldoc `<remarks>` (`:1180-1184`)
with the seam note (exact text in Task 10). **Tests:** none (doc-only). **Effort:** S (trivial).
**Risk:** none.
---
## Verification bar (house thesis: "unit-green ≠ wired")
**Deterministic unit guards** — every behavioral claim above has a fake-factory unit test that
fails at `f6eaa267` and passes after (T1-T3, T5-T9), plus two pinning tests (T4, existing
data-address-error test) proving the fixes didn't over-rotate. The fakes drive the *exact*
production code paths (real `S7Driver`, real gate, real poll/probe loops) — only the wire is
faked, and the STAB-14 fakes specifically make `OpenAsync` honour its token, which is the
property the live rig cannot simulate cheaply.
**Live gate (env-gated, operator-run)** — the existing bounce test cannot cover STAB-14/15
because `docker restart` produces connection-*refused* (instant `SocketException`), never
connect-*timeout*. The timeout variant needs the SYN-blackhole shape: **packets dropped, not
rejected**. Design (Task 11), mirroring `S7_RECONNECT_BOUNCE_CMD`'s double-gate:
- New `S7_1500ConnectTimeoutOutageTests` in
`tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/S7_1500/`, triple-gated on the sim
fixture + two env vars:
- `S7_TIMEOUT_OUTAGE_START_CMD` — begins dropping traffic to the sim port, e.g.
`ssh dohertj2@10.100.0.35 "sudo iptables -I INPUT -p tcp --dport 1102 -j DROP"`
- `S7_TIMEOUT_OUTAGE_STOP_CMD` — removes the rule (`-D INPUT …`).
Absent vars ⇒ clean `Assert.Skip` (safe offline on macOS; a `finally` always runs the stop
command once start succeeded, so the shared sim is never left blackholed).
- Body: subscribe against the live sim (`lmxopcua-fix up s7 s7_1500` on 10.100.0.35) → Good
baseline `OnDataChange` → run start-cmd → observe ≥1 Bad tick (each reconnect attempt now
times out rather than refusing) → run stop-cmd → assert a Good `OnDataChange` resumes **on the
same subscription** within 90 s. This is precisely the outage class STAB-14 killed; before the
fix this test would hang at the recovery assertion.
- A `docker pause otopcua-python-snap7-s7_1500` / `unpause` pair is an acceptable simpler
START/STOP command choice (paused container = ACKless blackhole for established flows and
unanswered SYNs for new connects) — document both in the test's remarks; the env-var design
deliberately leaves the mechanism to the operator.
Run recipe for the operator (also in the test xmldoc):
```bash
lmxopcua-fix up s7 s7_1500
export S7_TIMEOUT_OUTAGE_START_CMD='ssh dohertj2@10.100.0.35 "docker pause otopcua-python-snap7-s7_1500"'
export S7_TIMEOUT_OUTAGE_STOP_CMD='ssh dohertj2@10.100.0.35 "docker unpause otopcua-python-snap7-s7_1500"'
dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests --filter "Category=Reconnect"
```
---
## Task breakdown
TDD discipline throughout: the failing test lands (and is *observed* failing) before the code it
guards. Filter strings assume the repo root. Tasks 0-5 are Finding 1 (STAB-14); 6-9 are
Finding 2 (STAB-15); 10-12 close out. **Task 1 is the mandated connect-timeout regression test
and must be run and seen RED before any driver edit.**
### Task 0 — Extend the reconnect-test fakes with token-honouring hang modes
**Classification:** trivial
**Estimated implement time:** 5 min
**Parallelizable with:** nothing (everything depends on it)
**Files:**
- Modify: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
Steps:
1. In `FakeS7Plc`: add `public bool OpenHangsUntilCancelled { get; set; }`,
`public bool ReadHangsUntilCancelled { get; set; }`, `public bool WriteHangsUntilCancelled { get; set; }`,
`public Exception? ReadStatusThrows { get; set; }` (persistent, not one-shot),
`public bool ReadStatusHangsUntilCancelled { get; set; }`. In each corresponding method, when
the flag is set: `await Task.Delay(System.Threading.Timeout.Infinite, cancellationToken);`
(throws `TaskCanceledException` when the token fires) / `throw ReadStatusThrows` — placed
*before* the existing one-shot `*ThrowsOnce` handling. Convert the affected methods to
`async Task`.
2. In `FakeS7PlcFactory`: add `public int OpenHangsUntilCancelledCount { get; set; }` (each
`Create` decrements it and sets `plc.OpenHangsUntilCancelled = true` while positive) and
`public Exception? ReadStatusThrowsForNewConnections { get; set; }` (copied onto each created
plc; lets T8 arm connection #1 only by clearing it after init).
3. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests --filter "FullyQualifiedName~S7DriverReconnectTests"` — expected: **PASS** (existing 4 tests unaffected; compile-only change).
4. Commit: `test(s7): extend reconnect fakes with token-honouring hang + probe-fault modes (R2-01 task 0)`
### Task 1 — RED: the connect-timeout regression tests (T1 + T3) — MUST FAIL on current code
**Classification:** small
**Estimated implement time:** 5 min
**Parallelizable with:** —
**Files:**
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
Steps:
1. Write `Read_degrades_batch_on_connect_timeout_instead_of_throwing` (T1, Finding 1 Tests) and
`Write_degrades_batch_on_connect_timeout_instead_of_throwing` (T3): drop connection #1 via
`NextReadThrows = new PlcException(ErrorCode.ConnectionError, "dropped")` + one read to mark
dead; set `factory.OpenHangsUntilCancelledCount = int.MaxValue`; assert the next
`ReadAsync`/`WriteAsync` does **not** throw, returns non-zero statuses, and health is
`Degraded`.
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests --filter "FullyQualifiedName~connect_timeout"` — expected: **FAIL ×2** (`TaskCanceledException` escapes `ReadAsync`/`WriteAsync`). Record the failure output.
3. No commit yet (red tests commit together with Task 2's green).
### Task 2 — RED: the poll-loop-survival test (T2) + caller-cancel pinning test (T4)
**Classification:** small
**Estimated implement time:** 5 min
**Parallelizable with:** — (same file as Task 1; sequence after it)
**Files:**
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
Steps:
1. Write `Subscription_poll_loop_survives_a_connect_timeout_outage_and_recovers` (T2): subscribe
`["W0"]` at 100 ms; hook `OnDataChange` — set `sawBad` on `e.Snapshot.StatusCode != 0u`,
complete a `TaskCompletionSource` on the first Good snapshot after `sawBad`; drop connection
#1; `OpenHangsUntilCancelledCount = 2`; await the TCS with `WaitAsync(TimeSpan.FromSeconds(10))`.
2. Write `Read_still_propagates_caller_cancellation_during_connect` (T4): options with
`Timeout = TimeSpan.FromSeconds(5)`; mark dead; `OpenHangsUntilCancelledCount = 1`; caller
`CancellationTokenSource` with `CancelAfter(50)`; `Should.ThrowAsync<OperationCanceledException>`.
3. Run the two new tests — expected: **T2 FAIL** (10 s timeout — the loop died on the timeout
tick), **T4 PASS** (pins existing correct behavior).
4. No commit yet.
### Task 3 — GREEN: `EnsureConnectedAsync` + `InitializeAsync` timeout→`TimeoutException` conversion
**Classification:** standard
**Estimated implement time:** 5 min
**Parallelizable with:** —
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`EnsureConnectedAsync` `:1202-1212`; `InitializeAsync` `:184-196`)
Steps:
1. Apply Finding 1 implementation step 1 (exact code above) and step 4 (the `InitializeAsync`
mirror — filter on `!cancellationToken.IsCancellationRequested`).
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests --filter "FullyQualifiedName~S7DriverReconnectTests"` — expected: **ALL PASS** (T1/T2/T3 go green; T4 + the four pre-existing tests stay green).
3. Commit: `fix(s7): surface connect-timeout as TimeoutException, not OCE — poll loops no longer die on unreachable-host outages (STAB-14, R2-01)`
### Task 4 — Defensive `when` filters: ensure-wrappers + poll-loop catches
**Classification:** small
**Estimated implement time:** 5 min
**Parallelizable with:** Task 5
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`:488`, `:1000`, `:1383`, `:1396-1397`, `:1404`)
Steps:
1. Apply Finding 1 implementation steps 2 and 3 (exact code above). These are belt-and-suspenders
behind Task 3 — no reachable path produces a non-teardown OCE any more, so no new red test
exists; the deterministic guards are T2 (loop survival) and T4 (cancellation direction), which
must both stay green.
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests` — expected: **PASS** (whole project).
3. Commit: `fix(s7): filter OCE catches on the owning token in read/write wrappers + poll loop (STAB-14 defense-in-depth, R2-01)`
### Task 5 — Full S7 unit-suite regression sweep for Finding 1
**Classification:** trivial
**Estimated implement time:** 3 min
**Parallelizable with:** Task 4 (can be its verify step); listed separately as the finding-close gate
**Files:** none (test run only)
Steps:
1. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests` and
`dotnet test tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests` — expected: **PASS**.
2. No commit (gate only; if anything fails, fix within Tasks 3-4 scope before proceeding).
### Task 6 — RED: framing-fault classification tests (T5)
**Classification:** small
**Estimated implement time:** 5 min
**Parallelizable with:** Task 8 (different finding sub-part, same file — prefer sequencing)
**Files:**
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
Steps:
1. Write `[Theory]` `Framing_faults_are_classified_connection_fatal_and_reopen` with
`[MemberData]`/switch over four cases: `new TPKTInvalidException()`,
`new TPDUInvalidException()`, `new WrongNumberOfBytesException()`,
`new PlcException(ErrorCode.WrongNumberReceivedBytes, "short read")` (all public ctors,
verified against S7netplus 0.20.0). Shape: set as `NextReadThrows`; first read → non-zero
status, `Created.Count` still 1; second read → **Good** and `Created.Count == 2`,
`Created[0].Disposed` true.
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests --filter "FullyQualifiedName~Framing_faults"` — expected: **FAIL ×4** (`Created.Count` stays 1).
3. No commit yet.
### Task 7 — GREEN: broaden `IsS7ConnectionFatal`
**Classification:** small
**Estimated implement time:** 5 min
**Parallelizable with:** —
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`IsS7ConnectionFatal` `:1242-1252` + its xmldoc `:1231-1241`)
Steps:
1. Apply Finding 2 implementation step 1 (exact code above), including the NOT-`InvalidDataException`
comment and the xmldoc update naming the framing surface.
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests --filter "FullyQualifiedName~S7DriverReconnectTests"` — expected: **PASS** (T5 ×4 green; `Read_does_not_reopen_on_a_data_address_error` still green — the negative control).
3. Commit: `fix(s7): classify ISO-on-TCP framing/desync faults as connection-fatal (STAB-15a, R2-01)`
### Task 8 — RED→GREEN: cancellation-during-I/O marks the handle dead (T6 + T7)
**Classification:** standard
**Estimated implement time:** 5 min (tests) + 5 min (fix) — two sittings of ≤5 min
**Parallelizable with:** —
**Files:**
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`ReadAsync` per-item loop, insert before `:511`; `WriteAsync` OCE catch `:1043-1048`)
Steps:
1. Write `Cancelled_read_marks_handle_dead_and_next_read_reopens` (T6): `Created[0].ReadHangsUntilCancelled = true`;
caller CTS `CancelAfter(50)`; assert `Should.ThrowAsync<OperationCanceledException>` on the read;
then a fresh-token read → Good, `Created.Count == 2`. Write
`Cancelled_write_marks_handle_dead_and_next_read_reopens` (T7) with `WriteHangsUntilCancelled`.
2. Run `--filter "FullyQualifiedName~marks_handle_dead"` — expected: **FAIL ×2** (T6 additionally
fails its throw assertion today — the read path converts OCE to a Bad snapshot; T7 fails the
reopen assertion).
3. Apply Finding 2 implementation steps 2 and 3 (exact code above).
4. Re-run — expected: **PASS ×2**; then the whole `S7DriverReconnectTests` class — **PASS**.
5. Commit: `fix(s7): cancellation observed mid-PDU marks the connection dead before propagating (STAB-15a, R2-01)`
### Task 9 — RED→GREEN: probe marks the handle dead (T8 + T9)
**Classification:** standard
**Estimated implement time:** 5 min (tests) + 5 min (fix) — two sittings of ≤5 min
**Parallelizable with:** —
**Files:**
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DriverReconnectTests.cs`
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`ProbeLoopAsync` `:1516-1549`)
Steps:
1. Write `Probe_failure_on_connected_socket_marks_dead_and_next_tick_reopens` (T8): probe-enabled
options (`Probe = new S7ProbeOptions { Enabled = true, Interval = TimeSpan.FromMilliseconds(50), Timeout = TimeSpan.FromMilliseconds(250) }`);
after init, arm connection #1 with persistent `ReadStatusThrows = new SocketException()`
(leave later connections healthy); poll `factory.Created.Count` under a 5 s deadline until
`>= 2`, then assert a subsequent `GetHostStatuses()[0].State == HostState.Running` within a
further bounded window. Write `Probe_timeout_marks_dead` (T9): same shape with
`ReadStatusHangsUntilCancelled = true` on connection #1.
2. Run `--filter "FullyQualifiedName~Probe_"` (scoped to the reconnect class) — expected:
**FAIL ×2** (`Created.Count` pinned at 1 — the lying handle is re-probed forever).
3. Apply Finding 2 implementation step 4 (exact probe restructure above).
4. Re-run — expected: **PASS ×2**; whole test project — **PASS**.
5. Commit: `fix(s7): probe failures mark the handle dead under the gate so the next tick reopens (STAB-15b, R2-01)`
### Task 10 — Doc: the R2-09 connect-throttle seam note on `EnsureConnectedAsync`
**Classification:** trivial
**Estimated implement time:** 3 min
**Parallelizable with:** Tasks 6-9
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` (`EnsureConnectedAsync` `<remarks>` `:1180-1184`)
Steps:
1. Append to the `<remarks>`:
`While the PLC is down every data call and probe tick pays a full connect attempt bounded only by _options.Timeout (STAB-8). This method is the single choke-point all S7 reconnects flow through (already gate-serialized), so the fleet-wide connect-attempt throttle planned in R2-09 plugs in here: a last-failed-attempt timestamp checked at the top of the slow path. Deliberately NOT implemented driver-locally — see archreview/plans/R2-01-s7-fault-hardening-plan.md Finding 3.`
2. Build-only check (`dotnet build src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7`) — expected: **PASS**.
3. Commit: `docs(s7): mark EnsureConnectedAsync as the R2-09 connect-throttle seam (STAB-8 note, R2-01)`
### Task 11 — Env-gated live connect-timeout outage test (the STAB-14 live gate)
**Classification:** standard
**Estimated implement time:** 5 min (authoring; the live run is a separate operator action)
**Parallelizable with:** Tasks 6-10
**Files:**
- Create: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/S7_1500/S7_1500ConnectTimeoutOutageTests.cs`
Steps:
1. Author per the Verification-bar design: `[Collection(Snap7ServerCollection.Name)]`,
`[Trait("Category","Integration")]`, `[Trait("Category","Reconnect")]`,
`[Trait("Device","S7_1500")]`; triple-gated skip on `sim.SkipReason` +
`S7_TIMEOUT_OUTAGE_START_CMD` + `S7_TIMEOUT_OUTAGE_STOP_CMD`; reuse
`S7_1500ReconnectTests.RunBounceCommandAsync`'s shell-exec shape (copy the private helper —
or hoist it to the fixture if trivial); `try/finally` guarantees STOP runs once START
succeeded. Body: subscribe → Good baseline → START (blackhole) → observe ≥1 Bad
`OnDataChange` → STOP → await a Good `OnDataChange` on the same subscription within 90 s.
Xmldoc carries the operator recipe (docker pause/unpause and iptables DROP variants) and the
explicit rationale: `docker restart` = connection-refused; this test exists because STAB-14
only fires on connect-*timeout*.
2. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests --filter "FullyQualifiedName~ConnectTimeoutOutage"` locally (no env vars) — expected: **SKIP (cleanly)**.
3. Commit: `test(s7): env-gated live connect-timeout outage test — the STAB-14 outage class the bounce test cannot produce (R2-01)`
4. Note for the operator (not a CI step): run the recipe from the Verification-bar section
against the 10.100.0.35 fixture (`lmxopcua-fix up s7 s7_1500`) before trusting the fix live.
### Task 12 — Close-out: whole-solution S7-adjacent sweep + bookkeeping
**Classification:** trivial
**Estimated implement time:** 5 min
**Parallelizable with:** —
**Files:**
- Modify: `archreview/plans/STATUS.md` (mark R2-01 done, note the live-gate env vars)
- Modify: `archreview/05-protocol-drivers.md` (prior-finding table: STAB-14/15 → FIXED with commit refs; STAB-8 row: note the documented S7 seam)
Steps:
1. Run `dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests` and a solution build — expected: **PASS**.
2. Update the two archreview files (working-tree convention — these carry uncommitted re-review
state; follow whatever commit discipline the archreview docs branch is using at execution time).
3. Commit: `docs(archreview): R2-01 S7 fault-path hardening complete — STAB-14/15 fixed, STAB-8 seam documented`
---
## Effort & risk summary
| Finding | Effort | Risk / blast radius |
|---|---|---|
| STAB-14 (Tasks 0-5) | **S** | Low — four catch-clause edits, one file; regression guarded by T1-T4 + live gate |
| STAB-15 (Tasks 6-9) | **S-M** | Low-Medium — classifier + three catch sites + probe restructure, one file; guarded by T5-T9 + negative controls |
| STAB-8 note (Task 10) | **S** (trivial) | None — doc only |
| Live gate + close-out (Tasks 11-12) | **S** | None locally (env-gated skip); live run is operator-driven |
| **Overall** | **S-M** (~2-3 h implementer wall-time) | Single-file production change (`S7Driver.cs`); no contract/DI/schema changes |