Booted the server against the Modbus seed end-to-end to exercise the factory wiring shipped in #216 + #217. Surfaced two real issues with the seeds themselves; fixed both: 1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster` enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`. All four seed scripts now insert the binding row alongside the ClusterNode row. Without this, the server fails bootstrap with `BootstrapException: Central DB unreachable and no local cache available` (the Unauthorized error gets swallowed on top of the HTTP fallback path). 2. **Config cache gitignore.** Running the server from the repo root writes `config_cache.db` + `config_cache-log.db` next to the cwd, outside the existing `src/.../Server/config_cache.db` pattern. Add a `config_cache*.db` pattern so any future run location is covered. ## Verified live against Modbus Booted server against `seed-modbus-smoke.sql` → pymodbus standard fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`: === Modbus e2e summary: 4/5 passed === [PASS] Probe [PASS] Driver loopback [PASS] Server bridge (driver → server → client) [FAIL] OPC UA write bridge (0x801F0000) [PASS] Subscribe sees change The forward direction + subscription delivery are proven working through the server. The reverse-write failure is a seed-or-ACL issue — server log shows no exception on the write path, so the client-side status is coming from the stack's type/ACL guards. Tracking as a follow-up issue so the remaining three factory wirings can be smoke-booted against the same pattern. Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe` processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports 4840 + 4841 on this dev box; kill them first or bump the seed's DashboardPort. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
121 lines
5.2 KiB
Transact-SQL
121 lines
5.2 KiB
Transact-SQL
-- AB Legacy e2e smoke seed — closes #213 (umbrella #209).
|
|
--
|
|
-- Hardware-gated. The ab_server PCCC dispatcher is upstream-broken (task #222
|
|
-- tracks the lab rig + alternative fixtures), so verifying this seed end-to-end
|
|
-- requires real SLC 500 / MicroLogix / PLC-5 hardware or an RSEmulate 500
|
|
-- golden-box. The factory + seed ship here so the wiring is in place the
|
|
-- moment real hardware becomes available — no server code changes needed.
|
|
--
|
|
-- Usage (once hardware is reachable):
|
|
-- sqlcmd -S "localhost,14330" -d OtOpcUaConfig -U sa -P "OtOpcUaDev_2026!" \
|
|
-- -i scripts/smoke/seed-ablegacy-smoke.sql
|
|
-- (Update the `HostAddress` below to point at the real gateway first.)
|
|
|
|
SET NOCOUNT ON;
|
|
SET XACT_ABORT ON;
|
|
SET QUOTED_IDENTIFIER ON;
|
|
SET ANSI_NULLS ON;
|
|
SET ANSI_PADDING ON;
|
|
SET ANSI_WARNINGS ON;
|
|
SET ARITHABORT ON;
|
|
SET CONCAT_NULL_YIELDS_NULL ON;
|
|
|
|
DECLARE @ClusterId nvarchar(64) = 'ablegacy-smoke';
|
|
DECLARE @NodeId nvarchar(64) = 'ablegacy-smoke-node';
|
|
DECLARE @DrvId nvarchar(64) = 'ablegacy-smoke-drv';
|
|
DECLARE @NsId nvarchar(64) = 'ablegacy-smoke-ns';
|
|
DECLARE @AreaId nvarchar(64) = 'ablegacy-smoke-area';
|
|
DECLARE @LineId nvarchar(64) = 'ablegacy-smoke-line';
|
|
DECLARE @EqId nvarchar(64) = 'ablegacy-smoke-eq';
|
|
DECLARE @EqUuid uniqueidentifier = '5A1D2030-5A1D-4203-A5A1-D20305A1D203';
|
|
DECLARE @TagId nvarchar(64) = 'ablegacy-smoke-tag-n7_5';
|
|
|
|
BEGIN TRAN;
|
|
|
|
DELETE FROM dbo.Tag WHERE TagId IN (@TagId);
|
|
DELETE FROM dbo.Equipment WHERE EquipmentId = @EqId;
|
|
DELETE FROM dbo.UnsLine WHERE UnsLineId = @LineId;
|
|
DELETE FROM dbo.UnsArea WHERE UnsAreaId = @AreaId;
|
|
DELETE FROM dbo.DriverInstance WHERE DriverInstanceId = @DrvId;
|
|
DELETE FROM dbo.Namespace WHERE NamespaceId = @NsId;
|
|
DELETE FROM dbo.ConfigGeneration WHERE ClusterId = @ClusterId;
|
|
DELETE FROM dbo.ClusterNodeCredential WHERE NodeId = @NodeId;
|
|
DELETE FROM dbo.ClusterNodeGenerationState WHERE NodeId = @NodeId;
|
|
DELETE FROM dbo.ClusterNode WHERE NodeId = @NodeId;
|
|
DELETE FROM dbo.ServerCluster WHERE ClusterId = @ClusterId;
|
|
|
|
INSERT dbo.ServerCluster(ClusterId, Name, Enterprise, Site, NodeCount, RedundancyMode, Enabled, CreatedBy)
|
|
VALUES (@ClusterId, 'AB Legacy Smoke', 'zb', 'lab', 1, 'None', 1, 'ablegacy-smoke');
|
|
|
|
INSERT dbo.ClusterNode(NodeId, ClusterId, RedundancyRole, Host, OpcUaPort, DashboardPort,
|
|
ApplicationUri, ServiceLevelBase, Enabled, CreatedBy)
|
|
VALUES (@NodeId, @ClusterId, 'Primary', 'localhost', 4840, 5000,
|
|
'urn:OtOpcUa:ablegacy-smoke-node', 200, 1, 'ablegacy-smoke');
|
|
|
|
INSERT dbo.ClusterNodeCredential(NodeId, Kind, Value, Enabled, CreatedBy)
|
|
VALUES (@NodeId, 'SqlLogin', 'sa', 1, 'ablegacy-smoke');
|
|
|
|
DECLARE @Gen bigint;
|
|
INSERT dbo.ConfigGeneration(ClusterId, Status, CreatedBy)
|
|
VALUES (@ClusterId, 'Draft', 'ablegacy-smoke');
|
|
SET @Gen = SCOPE_IDENTITY();
|
|
|
|
INSERT dbo.Namespace(GenerationId, NamespaceId, ClusterId, Kind, NamespaceUri, Enabled)
|
|
VALUES (@Gen, @NsId, @ClusterId, 'Equipment', 'urn:ablegacy-smoke:eq', 1);
|
|
|
|
INSERT dbo.UnsArea(GenerationId, UnsAreaId, ClusterId, Name)
|
|
VALUES (@Gen, @AreaId, @ClusterId, 'lab-floor');
|
|
|
|
INSERT dbo.UnsLine(GenerationId, UnsLineId, UnsAreaId, Name)
|
|
VALUES (@Gen, @LineId, @AreaId, 'ablegacy-line');
|
|
|
|
INSERT dbo.Equipment(GenerationId, EquipmentId, EquipmentUuid, DriverInstanceId, UnsLineId,
|
|
Name, MachineCode, Enabled)
|
|
VALUES (@Gen, @EqId, @EqUuid, @DrvId, @LineId, 'slc-sim', 'ablegacy-001', 1);
|
|
|
|
-- AB Legacy DriverInstance — SLC 500 target. Replace the placeholder gateway
|
|
-- `192.168.1.10` with the real PLC / RSEmulate host before running.
|
|
INSERT dbo.DriverInstance(GenerationId, DriverInstanceId, ClusterId, NamespaceId,
|
|
Name, DriverType, DriverConfig, Enabled)
|
|
VALUES (@Gen, @DrvId, @ClusterId, @NsId, 'ablegacy-smoke', 'AbLegacy', N'{
|
|
"TimeoutMs": 2000,
|
|
"Devices": [
|
|
{
|
|
"HostAddress": "ab://192.168.1.10/1,0",
|
|
"PlcFamily": "Slc500",
|
|
"DeviceName": "slc-500"
|
|
}
|
|
],
|
|
"Probe": { "Enabled": true, "IntervalMs": 5000, "TimeoutMs": 2000, "ProbeAddress": "S:0" },
|
|
"Tags": [
|
|
{
|
|
"Name": "N7_5",
|
|
"DeviceHostAddress": "ab://192.168.1.10/1,0",
|
|
"Address": "N7:5",
|
|
"DataType": "Int",
|
|
"Writable": true,
|
|
"WriteIdempotent": true
|
|
}
|
|
]
|
|
}', 1);
|
|
|
|
INSERT dbo.Tag(GenerationId, TagId, DriverInstanceId, EquipmentId, Name, DataType,
|
|
AccessLevel, TagConfig, WriteIdempotent)
|
|
VALUES (@Gen, @TagId, @DrvId, @EqId, 'N7_5', 'Int16', 'ReadWrite',
|
|
N'{"FullName":"N7_5","Address":"N7:5","DataType":"Int"}', 1);
|
|
|
|
EXEC dbo.sp_PublishGeneration @ClusterId = @ClusterId, @DraftGenerationId = @Gen,
|
|
@Notes = N'AB Legacy smoke — task #213';
|
|
|
|
COMMIT;
|
|
|
|
PRINT '';
|
|
PRINT 'AB Legacy smoke seed complete.';
|
|
PRINT ' Cluster: ' + @ClusterId;
|
|
PRINT ' Node: ' + @NodeId;
|
|
PRINT ' Generation: ' + CONVERT(nvarchar(20), @Gen);
|
|
PRINT '';
|
|
PRINT 'NOTE: hardware-gated. ab_server PCCC is upstream-broken (#222). Point the';
|
|
PRINT ' DriverConfig HostAddress at real SLC / MicroLogix / PLC-5 / RSEmulate';
|
|
PRINT ' and run the e2e script with AB_LEGACY_TRUST_WIRE=1.';
|