Pin libplctag ab_server to v2.6.16 — real release tag + SHA256 hashes for all three Windows arches. Closes the "pick a current version + pin" deferral left by the #180 PR docs stub. Verified the release lands ab_server.exe inside libplctag_2.6.16_windows_<arch>_tools.zip alongside plctag.dll + list_tags_* helpers by downloading each tools zip + unzip -l'ing to confirm ab_server.exe is present at 331264 bytes. New ci/ab-server.lock.json is the single source of truth — one file the CI YAML reads via ConvertFrom-Json instead of duplicating the hash across the workflow + the docs. Structure: repo (libplctag/libplctag) + tag (v2.6.16) + published date (2026-03-29) + assets keyed by platform (windows-x64 / windows-x86 / windows-arm64) each carrying filename + sha256. docs/v2/test-data-sources.md §2.CI updated — replaces the prior placeholder (ver = '<pinned libplctag release tag>', expected = '<pinned sha256>') with the real v2.6.16 + 9b78a3de... hashes pinned table, and replaces the hardcoded URL with a lockfile-driven pwsh step that picks windows-x64 by default but swaps to x86/arm64 by changing one line for non-x64 CI runners. Hash-mismatch path throws with both the expected + actual values so on the first drift the CI log tells the maintainer exactly what to update in the lockfile. Two verification notes from the release fetch: (1) libplctag v2.6.16 tools zips ship ab_server.exe + plctag.dll together — tests don't need a separate libplctag NuGet download for the integration path, the extracted tools dir covers both the simulator + the driver's native dependency; (2) the three Windows arches all carry ab_server.exe, so ARM64 Windows GitHub runners (when they arrive) can run the integration suite without changes beyond swapping the asset key. No code changes in this PR — purely docs + the new lockfile. Admin tests + Core tests unchanged + passing per the prior commit.
2026-04-20 00:04:35 -04:00
Phase 2 official close-out. Closes task #209. The 2026-04-18 exit-gate-phase-2-final.md captured Phase 2 state at PR 2 merge — four High/Medium adversarial findings still OPEN, Historian port + alarm subsystem + v1 archive deletion all deferred. Since then: PR 4 closed all four findings end-to-end (High 1 Read subscription-leak, High 2 no reconnect loop, Medium 3 SubscribeAsync doesn't push frames, Medium 4 WriteValuesAsync doesn't await OnWriteComplete — mapped + resolved inline in the new doc), PR 12 landed the richer historian quality mapper, PR 13 shipped GalaxyRuntimeProbeManager with per-Platform/AppEngine ScanState subscriptions + StateChanged events forwarded through the existing OnHostStatusChanged IPC frame, PR 14 wired the alarm subsystem (GalaxyAlarmTracker advising the four alarm-state attributes per IsAlarm=true attribute, raising AlarmTransition events forwarded through OnAlarmEvent IPC frames), Phase 3 PR 18 deleted the v1 source trees, and PR 61 closed V1_ARCHIVE_STATUS.md. Phase 2 is functionally done; this commit is the bookkeeping pass. New exit-gate-phase-2-closed.md at docs/v2/implementation/ — five-stream status table (A/B/C/D/E all complete with the specific close commits named), full resolution table for every 2026-04-18 adversarial finding mapped to the PR 4 resolution, cross-cutting deferrals table marking every one resolved (Historian SDK plugin port → done, subscription push frames → done under Medium 3, Historian-backed HistoryRead → done, alarm subsystem wire-up → done, reconnect-without-recycle → done under High 2, v1 archive deletion → done). Fresh 2026-04-20 test baseline captured from the current v2 tip: 1844 passing + 29 infra-gated skips across 21 test projects, including the net48 x86 Galaxy.Host.Tests suite (107 pass) that exercises the MXAccess COM path on the dev box. Flake observed — Configuration.Tests 70/71 on first full-solution run, 71/71 on retry; logged as a known non-stable flake rather than chased because it did not reproduce. The prior exit-gate-phase-2-final.md is kept in place (historical record of the 2026-04-18 snapshot) but gets a superseded-by banner at the top pointing at the new close-out doc so future readers land on current status first. docs/v2/plan.md Phase 2 section header gains the CLOSED 2026-04-20 marker + a link to the close-out doc so the top-level plan index reflects reality. "What Phase 2 closed means for Phase 3 and later" section in the new doc captures the downstream contract: Galaxy now runs as a first-class v2 driver with the same capability-interface shape as Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient; no v1 code path remains; the 2026-04-13 stability findings persist as named regression tests under tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/StabilityFindingsRegressionTests.cs so any future refactor reintroducing them trips the test. "Outstanding — not Phase 2 blockers" section lists the four pending non-Phase-2 tasks (#177, #194, #195, #199) so nobody mistakes them for Phase 2 tail work.
2026-04-20 02:00:35 -04:00
Client rename residuals: lmxopcua-cli → otopcua-cli + LmxOpcUaClient → OtOpcUaClient with migration shim. Closes task #208 (the executable-name + LocalAppData-folder slice that was called out in Client.CLI.md / Client.UI.md as a deliberately-deferred residual of the Phase 0 rename). Six source references flipped to the canonical OtOpcUaClient spelling: Program.cs CliFx executable name + description (lmxopcua-cli → otopcua-cli), DefaultApplicationConfigurationFactory.cs ApplicationName + ApplicationUri (LmxOpcUaClient + urn:localhost:LmxOpcUaClient → OtOpcUaClient + urn:localhost:OtOpcUaClient), OpcUaClientService.CreateSessionAsync session-name arg, ConnectionSettings.CertificateStorePath default, MainWindowViewModel.CertificateStorePath default, JsonSettingsService.SettingsDir. Two consuming tests (ConnectionSettingsTests + MainWindowViewModelTests) updated to assert the new canonical name. New ClientStoragePaths static helper at src/ZB.MOM.WW.OtOpcUa.Client.Shared/ClientStoragePaths.cs is the migration shim — single entry point for the PKI root + pki subpath, runs a one-shot legacy-folder probe on first resolution: if {LocalAppData}/LmxOpcUaClient/ exists + {LocalAppData}/OtOpcUaClient/ does not, Directory.Move renames it in place (atomic on NTFS within the same volume) so trusted server certs + saved connection settings persist across the rename without operator action. Idempotent per-process via a Lock-guarded _migrationChecked flag so repeated CertificateStorePath getter calls on the hot path pay no IO cost beyond the first. Fresh-install path (neither folder exists) + already-migrated path (only canonical exists) + manual-override path (both exist — developer has set up something explicit) are all no-ops that leave state alone. IOException on the Directory.Move is swallowed + logged as a false return so a concurrent peer process losing the race doesn't crash the consumer; the losing process falls back to whatever state exists. Five new ClientStoragePathsTests assert: GetRoot ends with canonical name under LocalAppData, GetPkiPath nests pki under root, CanonicalFolderName is OtOpcUaClient, LegacyFolderName is LmxOpcUaClient (the migration contract — a typo here would leak the legacy folder past the shim), repeat invocation returns false after first-touch arms the in-process guard. Doc-side residual-explanation notes in docs/Client.CLI.md + docs/Client.UI.md are dropped now that the rename is real; replaced with a short "pre-#208 dev boxes migrate automatically on first launch" note that points at ClientStoragePaths. Sample CLI invocations in Client.CLI.md updated via sed from lmxopcua-cli to otopcua-cli across every command block (14 replacements). Pre-existing staleness in SubscribeCommandTests.Execute_PrintsSubscriptionMessage surfaced during the test run — the CLI's subscribe command has long since switched to an aggregate "Subscribed to {count}/{total} nodes (interval: ...)" output format but the test still asserted the original single-node form. Updated the assertion to match current output + added a comment explaining the change; this is unrelated to the rename but was blocking a green Client.CLI.Tests run. Full solution build 0 errors; Client.Shared.Tests 136/136 + 5 new shim tests passing; Client.UI.Tests 98/98; Client.CLI.Tests 52/52 (was 51/52 before the subscribe-test fix). No Admin/Core/Server changes — this touches only the client layer.
2026-04-20 01:50:40 -04:00
Client rename residuals: lmxopcua-cli → otopcua-cli + LmxOpcUaClient → OtOpcUaClient with migration shim. Closes task #208 (the executable-name + LocalAppData-folder slice that was called out in Client.CLI.md / Client.UI.md as a deliberately-deferred residual of the Phase 0 rename). Six source references flipped to the canonical OtOpcUaClient spelling: Program.cs CliFx executable name + description (lmxopcua-cli → otopcua-cli), DefaultApplicationConfigurationFactory.cs ApplicationName + ApplicationUri (LmxOpcUaClient + urn:localhost:LmxOpcUaClient → OtOpcUaClient + urn:localhost:OtOpcUaClient), OpcUaClientService.CreateSessionAsync session-name arg, ConnectionSettings.CertificateStorePath default, MainWindowViewModel.CertificateStorePath default, JsonSettingsService.SettingsDir. Two consuming tests (ConnectionSettingsTests + MainWindowViewModelTests) updated to assert the new canonical name. New ClientStoragePaths static helper at src/ZB.MOM.WW.OtOpcUa.Client.Shared/ClientStoragePaths.cs is the migration shim — single entry point for the PKI root + pki subpath, runs a one-shot legacy-folder probe on first resolution: if {LocalAppData}/LmxOpcUaClient/ exists + {LocalAppData}/OtOpcUaClient/ does not, Directory.Move renames it in place (atomic on NTFS within the same volume) so trusted server certs + saved connection settings persist across the rename without operator action. Idempotent per-process via a Lock-guarded _migrationChecked flag so repeated CertificateStorePath getter calls on the hot path pay no IO cost beyond the first. Fresh-install path (neither folder exists) + already-migrated path (only canonical exists) + manual-override path (both exist — developer has set up something explicit) are all no-ops that leave state alone. IOException on the Directory.Move is swallowed + logged as a false return so a concurrent peer process losing the race doesn't crash the consumer; the losing process falls back to whatever state exists. Five new ClientStoragePathsTests assert: GetRoot ends with canonical name under LocalAppData, GetPkiPath nests pki under root, CanonicalFolderName is OtOpcUaClient, LegacyFolderName is LmxOpcUaClient (the migration contract — a typo here would leak the legacy folder past the shim), repeat invocation returns false after first-touch arms the in-process guard. Doc-side residual-explanation notes in docs/Client.CLI.md + docs/Client.UI.md are dropped now that the rename is real; replaced with a short "pre-#208 dev boxes migrate automatically on first launch" note that points at ClientStoragePaths. Sample CLI invocations in Client.CLI.md updated via sed from lmxopcua-cli to otopcua-cli across every command block (14 replacements). Pre-existing staleness in SubscribeCommandTests.Execute_PrintsSubscriptionMessage surfaced during the test run — the CLI's subscribe command has long since switched to an aggregate "Subscribed to {count}/{total} nodes (interval: ...)" output format but the test still asserted the original single-node form. Updated the assertion to match current output + added a comment explaining the change; this is unrelated to the rename but was blocking a green Client.CLI.Tests run. Full solution build 0 errors; Client.Shared.Tests 136/136 + 5 new shim tests passing; Client.UI.Tests 98/98; Client.CLI.Tests 52/52 (was 51/52 before the subscribe-test fix). No Admin/Core/Server changes — this touches only the client layer.
2026-04-20 01:50:40 -04:00
Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
2026-04-18 22:57:03 -04:00
Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
2026-04-18 22:57:03 -04:00
Roslyn analyzer — detect unwrapped driver-capability calls (OTOPCUA0001). Closes task #200. New netstandard2.0 analyzer project src/ZB.MOM.WW.OtOpcUa.Analyzers registered as an <Analyzer>-item ProjectReference from the Server csproj so the warning fires at every Server compile. First (and only so far) rule OTOPCUA0001 — "Driver capability call must be wrapped in CapabilityInvoker" — walks every InvocationOperation in the AST + trips when (a) the target method implements one of the seven guarded capability interfaces (IReadable / IWritable / ITagDiscovery / ISubscribable / IHostConnectivityProbe / IAlarmSource / IHistoryProvider) AND (b) the method's return type is Task, Task<T>, ValueTask, or ValueTask<T> — the async-wire-call constraint narrows the rule to the surfaces the Phase 6.1 pipeline actually wraps + sidesteps pure in-memory accessors like IHostConnectivityProbe.GetHostStatuses() which would trigger false positives AND (c) the call does NOT sit inside a lambda argument passed to CapabilityInvoker.ExecuteAsync / ExecuteWriteAsync / AlarmSurfaceInvoker.*. The wrapper detection walks up the syntax tree from the call site, finds any enclosing InvocationExpressionSyntax whose method's containing type is one of the wrapper classes, + verifies the call lives transitively inside that invocation's AnonymousFunctionExpressionSyntax argument — a sibling "result = await driver.ReadAsync(...)" followed by a separate invoker.ExecuteAsync(...) call does NOT satisfy the wrapping rule + the analyzer flags it (regression guard in the 5th test). Five xunit-v3 + Shouldly tests at tests/ZB.MOM.WW.OtOpcUa.Analyzers.Tests: direct ReadAsync in server namespace trips; wrapped ReadAsync inside CapabilityInvoker.ExecuteAsync lambda passes; direct WriteAsync trips; direct DiscoverAsync trips; sneaky pattern — read outside the lambda + ExecuteAsync with unrelated lambda nearby — still trips. Hand-rolled test harness compiles a stub-plus-user snippet via CSharpCompilation.WithAnalyzers + runs GetAnalyzerDiagnosticsAsync directly, deliberately avoiding Microsoft.CodeAnalysis.CSharp.Analyzer.Testing.XUnit because that package pins to xunit v2 + this repo is on xunit.v3 everywhere else. RS2008 release-tracking noise suppressed by adding AnalyzerReleases.Shipped.md + AnalyzerReleases.Unshipped.md as AdditionalFiles, which is the canonical Roslyn-analyzer hygiene path. Analyzer DLL referenced from Server.csproj via ProjectReference with OutputItemType=Analyzer + ReferenceOutputAssembly=false — the DLL ships as a compiler plugin, not a runtime dependency. Server build validates clean: the analyzer activates on every Server file but finds zero violations, which confirms the Phase 6.1 wrapping work done in prior PRs is complete + the analyzer is now the regression guard preventing the next new capability surface from being added raw. slnx updated with both the src + tests project entries. Full solution build clean, analyzer suite 5/5 passing.
2026-04-20 00:52:40 -04:00

LmxOpcUa

OPC UA server and cross-platform client tools for AVEVA System Platform (Wonderware) Galaxy. The server exposes Galaxy tags via MXAccess as an OPC UA address space. The client stack provides a shared library, CLI tool, and Avalonia desktop application for browsing, reading/writing, subscriptions, alarms, and historical data.

Architecture

                                    OPC UA Clients
                              (CLI, Desktop UI, 3rd-party)
                                         |
                                         v
+-----------------+     +------------------+     +-----------------+
| Galaxy Repo DB  |---->|   OPC UA Server  |<--->| MXAccess Client |
|   (SQL Server)  |     | (address space)  |     | (STA + COM)     |
+-----------------+     +------------------+     +-----------------+
                                |                        |
                        +-------+--------+     +---------+---------+
                        | Status Dashboard|     | Historian Runtime |
                        |  (HTTP/JSON)   |     |   (SQL Server)    |
                        +----------------+     +-------------------+

Contained Name vs Tag Name

Browse Path (contained names) Runtime Reference (tag name)
TestMachine_001/DelmiaReceiver/DownloadPath DelmiaReceiver_001.DownloadPath
TestMachine_001/MESReceiver/MoveInBatchID MESReceiver_001.MoveInBatchID

Server

The OPC UA server runs on .NET Framework 4.8 (x86) and bridges the Galaxy runtime to OPC UA clients.

Server Prerequisites

  • .NET Framework 4.8 SDK
  • AVEVA System Platform with ArchestrA Framework installed
  • Galaxy repository database (SQL Server, Windows Auth)
  • MXAccess COM registered (LMXProxy.LMXProxyServer)
  • Wonderware Historian (optional, for historical data access)
  • Windows (required for COM interop and MXAccess)

Build and Run Server

dotnet restore ZB.MOM.WW.LmxOpcUa.slnx
dotnet build src/ZB.MOM.WW.LmxOpcUa.Host
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Host

The server starts on opc.tcp://localhost:4840/LmxOpcUa with the None security profile by default. Configure Security.Profiles in appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt for transport security. See Security Guide.

Install as Windows Service

cd src/ZB.MOM.WW.LmxOpcUa.Host/bin/Debug/net48
ZB.MOM.WW.LmxOpcUa.Host.exe install
ZB.MOM.WW.LmxOpcUa.Host.exe start

Service logon requirement: The service must run under a Windows account that has access to the AVEVA Galaxy and Historian. The default LocalSystem account can connect to MXAccess and SQL Server but cannot authenticate with the Historian SDK (HCAP). Configure the service to "Log on as" a domain or local user that is a recognized ArchestrA platform user. This can be set in services.msc or during install with ZB.MOM.WW.LmxOpcUa.Host.exe install -username DOMAIN\user -password ***.

Run Server Tests

dotnet test tests/ZB.MOM.WW.LmxOpcUa.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.IntegrationTests

Client Stack

The client stack is cross-platform (.NET 10) and consists of three projects sharing a common IOpcUaClientService abstraction. No AVEVA software or COM is required — the clients connect to any OPC UA server.

Client Prerequisites

  • .NET 10 SDK
  • No platform-specific dependencies (runs on Windows, macOS, Linux)

Build All Clients

dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.Shared
dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.CLI
dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.UI

Run Client Tests

dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.Shared.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.CLI.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.UI.Tests

Client CLI

# Connect
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840/LmxOpcUa

# Browse Galaxy hierarchy
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=ZB" -r -d 5

# Read a tag
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001.MachineID"

# Write a tag
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestChildObject.TestString" -v "Hello"

# Subscribe to changes
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestChildObject.TestInt" -i 500

# Read historical data
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- historyread -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001.TestHistoryValue" --start "2026-03-25" --end "2026-03-30"

# Subscribe to alarm events
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- alarms -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001" --refresh

# Query redundancy state
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- redundancy -u opc.tcp://localhost:4840/LmxOpcUa

Client UI

dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.UI

The desktop application provides browse tree, subscriptions, alarm monitoring, history reads, and write dialogs. See Client UI Documentation for details.


Project Structure

src/
    ZB.MOM.WW.LmxOpcUa.Host/           OPC UA server (.NET Framework 4.8, x86)
        Configuration/                   Config binding and validation
        Domain/                          Interfaces, DTOs, enums, mappers
        Historian/                       Wonderware Historian data source
        Metrics/                         Performance tracking (rolling P95)
        MxAccess/                        STA thread, COM interop, subscriptions
        GalaxyRepository/                SQL queries, change detection
        OpcUa/                           Server, node manager, address space, alarms, diff
        Status/                          HTTP dashboard, health checks

    ZB.MOM.WW.LmxOpcUa.Client.Shared/   Shared OPC UA client library (.NET 10)
    ZB.MOM.WW.LmxOpcUa.Client.CLI/      Command-line client (.NET 10)
    ZB.MOM.WW.LmxOpcUa.Client.UI/       Avalonia desktop client (.NET 10)

tests/
    ZB.MOM.WW.LmxOpcUa.Tests/           Server unit + integration tests
    ZB.MOM.WW.LmxOpcUa.IntegrationTests/ Server integration tests (live DB)
    ZB.MOM.WW.LmxOpcUa.Client.Shared.Tests/  Shared library tests
    ZB.MOM.WW.LmxOpcUa.Client.CLI.Tests/     CLI command tests
    ZB.MOM.WW.LmxOpcUa.Client.UI.Tests/      UI ViewModel + headless tests

gr/                                      Galaxy repository docs, SQL queries, schema

Documentation

Server

Component Description
OPC UA Server Endpoint, sessions, security policy, server lifecycle
Address Space Hierarchy nodes, variable nodes, primitive grouping, NodeId scheme
Galaxy Repository SQL queries, deployed package chain, change detection
MXAccess Bridge STA thread, COM interop, subscriptions, reconnection
Data Type Mapping Galaxy to OPC UA types, arrays, security classification
Read/Write Operations Value reads, writes, access level enforcement, array element writes
Subscriptions Ref-counted MXAccess subscriptions, data change dispatch
Alarm Tracking AlarmConditionState nodes, InAlarm monitoring, event reporting
Historical Data Access Historian data source, HistoryReadRaw, HistoryReadProcessed
Incremental Sync Diff computation, subtree teardown/rebuild, subscription preservation
Configuration appsettings.json binding, feature flags, validation
Status Dashboard HTTP server, health checks, metrics reporting
Service Hosting TopShelf, startup/shutdown sequence, error handling
Security Transport security profiles, certificate trust, production hardening
Redundancy Non-transparent warm/hot redundancy, ServiceLevel, paired deployment

Client

Component Description
Client CLI Connect, browse, read, write, subscribe, historyread, alarms, redundancy commands
Client UI Avalonia desktop client: browse, subscribe, alarms, history, write values

Reference

License

Internal use only.

Description
No description provided
Readme 12 MiB
Languages
C# 94.6%
TSQL 4.9%
Python 0.3%
Batchfile 0.2%