117 lines
4.2 KiB
PowerShell
117 lines
4.2 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the AB Legacy (PCCC) driver.
|
|
|
|
.DESCRIPTION
|
|
Runs against libplctag's ab_server PCCC Docker fixture (one of the
|
|
slc500 / micrologix / plc5 compose profiles) or real SLC / MicroLogix /
|
|
PLC-5 hardware. Five assertions: probe / driver-loopback / forward-
|
|
bridge / reverse-bridge / subscribe-sees-change.
|
|
|
|
ab_server enforces a non-empty CIP routing path (`/1,0`) before the
|
|
PCCC dispatcher runs; real hardware accepts an empty path. The default
|
|
$Gateway uses `/1,0` for the Docker fixture — pass `-Gateway
|
|
"ab://host:44818/"` when pointing at a real SLC 5/05 / MicroLogix /
|
|
PLC-5.
|
|
|
|
.PARAMETER Gateway
|
|
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0 (Docker fixture).
|
|
|
|
.PARAMETER PlcType
|
|
Slc500 / MicroLogix / Plc5 / LogixPccc (default Slc500).
|
|
|
|
.PARAMETER Address
|
|
PCCC address to exercise. Default N7:5.
|
|
|
|
.PARAMETER OpcUaUrl
|
|
OtOpcUa server endpoint.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
NodeId at which the server publishes the Address.
|
|
#>
|
|
|
|
param(
|
|
[string]$Gateway = "ab://127.0.0.1/1,0",
|
|
[string]$PlcType = "Slc500",
|
|
[string]$Address = "N7:5",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
# ab_server PCCC works; the earlier "upstream-broken" gate is gone. The only
|
|
# caveat: libplctag's ab_server rejects empty CIP paths, so $Gateway must
|
|
# carry a non-empty path segment (default /1,0). Real SLC/PLC-5 hardware
|
|
# accepts an empty path — use `ab://host:44818/` when pointing at real PLCs.
|
|
|
|
$abLegacyCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli" `
|
|
-ExeName "otopcua-ablegacy-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonAbLegacy = @("-g", $Gateway, "-P", $PlcType)
|
|
$results = @()
|
|
|
|
$results += Test-Probe `
|
|
-Cli $abLegacyCli `
|
|
-ProbeArgs (@("probe") + $commonAbLegacy + @("-a", "N7:0"))
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $abLegacyCli `
|
|
-WriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
|
$results += Test-OpcUaWriteBridge `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
|
|
-ExpectedValue "$reverseValue"
|
|
|
|
$subValue = Get-Random -Minimum 30000 -Maximum 32766
|
|
$results += Test-SubscribeSeesChange `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $subValue)) `
|
|
-ExpectedValue "$subValue"
|
|
|
|
# PR 7 — contiguous array read smoke. The default `--tag=N7[120]` in the Docker
|
|
# fixture's docker-compose.yml has plenty of room for `,10`; against real hardware
|
|
# the seeded N7 file just needs at least 10 words. Asserts the CLI exits 0 (the
|
|
# driver issued one PCCC frame for the whole block) — the per-element values are
|
|
# whatever the device currently holds.
|
|
Write-Header "Array contiguous read"
|
|
$arrayResult = Invoke-Cli -Cli $abLegacyCli `
|
|
-Args (@("read") + $commonAbLegacy + @("-a", "N7:0,10", "-t", "Int"))
|
|
if ($arrayResult.ExitCode -eq 0) {
|
|
Write-Pass "array read N7:0,10 succeeded"
|
|
$results += @{ Passed = $true }
|
|
} else {
|
|
Write-Fail "array read N7:0,10 exit=$($arrayResult.ExitCode)"
|
|
Write-Host $arrayResult.Output
|
|
$results += @{ Passed = $false; Reason = "array read exit $($arrayResult.ExitCode)" }
|
|
}
|
|
|
|
Write-Summary -Title "AB Legacy e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|