BoundedApiKeyStore bounded ConfigDbApiKeyStore with a CancellationTokenSource(TimeSpan, TimeProvider) linked into the inner call. That bounds the call only if the callee chooses to observe the token, and Microsoft.Data.SqlClient does not while a connect/login is in flight on a black-holed socket. The 2026-08-20 live gate paused the SQL container and watched a keyed activation hang 42.9 s past its 2000 ms bound — the "did not answer within 2000 ms" Warning fired only at unpause — and because this runs inside the SDK's synchronous SessionManager-lock-holding impersonation callback, an unrelated already-open subscription stalled 57 s behind it. That is precisely the hazard the bound exists to prevent, and the TTL cache cannot help a miss. BoundAsync now races the inner call against Task.Delay on the injected clock with Task.WhenAny. Inner wins: stop the timer, await it, faults and genuine caller cancellation propagate unchanged. Delay wins: cancel the linked token anyway (a cooperative inner store should still stop), hand the abandoned task to ObserveAbandoned, meter outcome=timeout, log the now-honest Warning, and throw OperationCanceledException — the same exception the authenticator's catch-all already maps to the standard opaque denial. Fail-closed is unchanged: nothing here can admit. ObserveAbandoned disposes the CTS and TOUCHES finished.Exception (the observation itself), so a late SqlClient fault can never become an UnobservedTaskException. Debug, not Warning — the timeout is already reported at Warning, and an outage must not produce two lines per activation for one event. An abandoned answer is NEVER cached: it was taken before the deadline and would be served after it, so a key revoked or expired in the meantime could be admitted from a lookup nobody was still waiting for. StoreTimeoutMs <= 0 still short-circuits to the unbounded call byte-for-byte (the documented rollback). RED BEFORE GREEN. Every pre-existing deadline test drives GatedApiKeyStore, whose waits take the token, so a cooperative CancelAfter unblocks them and all 15 passed against the defective build — the suite could not see the gate's failure at all. The new UncooperativeApiKeyStore ignores ct entirely and completes only when the test releases it. Against the unmodified store the three new tests fail 3/18 with "should throw OperationCanceledException but threw TimeoutException" under a test-side WaitAsync(2 s), so the red is a failure and not a hang — and that exception swap IS the finding restated as an assertion. Host.Tests 137/137.
OtOpcUa documentation
Two tiers of documentation live here:
- Current reference at the top level (
docs/*.md) — describes what's shipped today. Start here for operator + integrator reference. - Implementation history + design notes at
docs/v2/*.md— the authoritative plan + decision log the current reference is built from. Start here when you need the why behind an architectural choice, or when a top-level doc says "see plan.md § X".
The project was originally called LmxOpcUa (a single-driver Galaxy/MXAccess OPC UA server) and has since become OtOpcUa, a multi-driver OPC UA server platform. Any lingering LmxOpcUa-string in a path you see in docs is a deliberate residual (executable name lmxopcua-cli, client PKI folder {LocalAppData}/LmxOpcUaClient/) — fixing those requires migration shims + is tracked as follow-ups.
Platform overview
v2 (2026-05-26): the separate
OtOpcUa.Server+OtOpcUa.Adminservices fused into a single role-gatedOtOpcUa.Hostbinary, joined by an Akka.NET cluster. See v2 design for the architectural decision.
- Core owns shared abstractions (driver capability contracts, scripting, virtual tags, alarm historian).
- Drivers plug in via capability interfaces in
ZB.MOM.WW.OtOpcUa.Core.Abstractions:IDriver,IReadable,IWritable,ITagDiscovery,ISubscribable,IHostConnectivityProbe,IAlarmSource,IHistoryProvider,IPerCallHostResolver. Each driver opts into whichever it supports. - Host (
src/Server/ZB.MOM.WW.OtOpcUa.Host) is the single fused binary (.NET 10, AnyCPU).OTOPCUA_ROLESenv decides what to mount:admin(Blazor + control-plane singletons),driver(OPC UA endpoint + per-node actors), or both. See ServiceHosting.md. - Cluster + ControlPlane + Runtime + AdminUI + Security sit between Core and Host. The cluster glues per-node actors into one logical fleet; the control-plane singletons (deploy coordinator, audit writer, redundancy state) live on the admin role-leader. See Redundancy.md.
- The Galaxy driver still reaches MXAccess via gRPC to a separately-installed mxaccessgw sidecar (sibling repo).
Where to find what
Architecture + data-path reference
| Doc | Covers |
|---|---|
| OpcUaServer.md | Top-level server architecture — Core, driver dispatch, Config DB, generations |
| AddressSpace.md | GenericDriverNodeManager + ITagDiscovery + IAddressSpaceBuilder |
| ReadWriteOperations.md | OPC UA Read/Write → CapabilityInvoker → IReadable/IWritable |
| DriverLifecycle.md | Server-side driver lifecycle + infrastructure contracts (IDriverFactory, IDriverProbe, IDriverHealthPublisher, IDriverConfigEditor, IHistorianDataSource) + the Commons library |
| Subscriptions.md | Monitored items → ISubscribable + per-driver subscription refcount (v1 archive) |
| AlarmTracking.md | IAlarmSource + AlarmSurfaceInvoker + OPC UA alarm conditions — native Galaxy alarms end-to-end (live) |
| AlarmTracking.md | Original alarm-tracking write-up (v1 archive) |
| AlarmHistorian.md | Core.AlarmHistorian store-and-forward sink — LocalDbStoreAndForwardSink, the replicated alarm_sf_events buffer + Primary-only drain, IAlarmHistorianWriter, dead-letter/retry/eviction |
| DataTypeMapping.md | Per-driver DriverAttributeInfo → OPC UA variable types (v1 archive — live mapping is in src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Galaxy/Browse/DataTypeMap.cs) |
| IncrementalSync.md | Address-space rebuild on redeploy + sp_ComputeGenerationDiff |
| HistoricalDataAccess.md | IHistoryProvider as a per-driver optional capability (v1 archive) |
| VirtualTags.md | Core.Scripting + Core.VirtualTags — Roslyn script sandbox, engine, dispatch alongside driver tags |
| ScriptEditor.md | Monaco script editor — Roslyn-backed IntelliSense (completions, diagnostics, hover, tag-path) for C# virtual-tag scripts; AdminUI/ScriptAnalysis/ backend |
| ScriptedAlarms.md | Core.ScriptedAlarms — script-predicate IAlarmSource + Part 9 state machine |
One Core subsystem is shipped without a dedicated top-level doc; see the section in the linked doc:
| Project | See |
|---|---|
Analyzers (Roslyn OTOPCUA0001) |
security.md § OTOPCUA0001 Analyzer |
Drivers
| Doc | Covers |
|---|---|
| drivers/README.md | Index of the eight shipped drivers + capability matrix |
| drivers/Galaxy.md | Galaxy driver — in-process gRPC client to the mxaccessgw sidecar |
| v1/drivers/Galaxy-Repository.md | Galaxy-specific discovery via the ZB SQL database (v1 archive — the gateway owns this path now) |
For Modbus / S7 / AB CIP / AB Legacy / TwinCAT / FOCAS / OPC UA Client specifics, see v2/driver-specs.md.
Operational
| Doc | Covers |
|---|---|
| Configuration.md | Live appsettings + environment-variable reference (current state) |
| Configuration.md | appsettings bootstrap + Config DB + Admin UI draft/publish (v1 archive — OTOPCUA_GALAXY_* env vars now live in mxaccessgw config) |
| Uns.md | The global /uns master tree — manage Area/Line/Equipment/Tag/VirtualTag fleet-wide; replaces the per-cluster UNS/Equipment/Tags tabs |
| security.md | Transport security profiles, LDAP auth, ACL trie, role grants, OTOPCUA0001 analyzer |
| Redundancy.md | RedundancyStateActor (cluster-scoped singleton), ServiceLevelCalculator, IRedundancyRoleView, per-cluster meshes, Prometheus metrics |
| Reservations.md | Fleet-wide ZTag / SAPID external-ID reservations — publish-time claim, release flow |
| ServiceHosting.md | Single fused OtOpcUa.Host binary install/uninstall with OTOPCUA_ROLES gating; the historian backend is the external HistorianGateway |
| StatusDashboard.md | Pointer — superseded by v2/admin-ui.md |
Client tooling
| Doc | Covers |
|---|---|
| Client.CLI.md | otopcua-cli — OPC UA command-line client |
| Client.UI.md | Avalonia desktop client |
| DriverClis.md | Driver test-client CLIs — index + shared commands |
| Driver.Modbus.Cli.md | otopcua-modbus-cli — Modbus-TCP |
| Driver.AbCip.Cli.md | otopcua-abcip-cli — ControlLogix / CompactLogix / Micro800 / GuardLogix |
| Driver.AbLegacy.Cli.md | otopcua-ablegacy-cli — SLC / MicroLogix / PLC-5 (PCCC) |
| Driver.S7.Cli.md | otopcua-s7-cli — Siemens S7-300 / S7-400 / S7-1200 / S7-1500 |
| Driver.TwinCAT.Cli.md | otopcua-twincat-cli — Beckhoff TwinCAT 2/3 ADS |
| Driver.FOCAS.Cli.md | otopcua-focas-cli — Fanuc FOCAS/2 CNC |
Requirements
| Doc | Covers |
|---|---|
| reqs/HighLevelReqs.md | HLRs — numbered system-level requirements |
| reqs/OpcUaServerReqs.md | OPC UA server-layer reqs |
| v1/reqs/ServiceHostReqs.md | Per-process hosting reqs (v1 archive — only OtOpcUa server hosting remains in scope post-PR-7.2) |
| reqs/ClientRequirements.md | Client CLI + UI reqs |
| v1/reqs/GalaxyRepositoryReqs.md | Galaxy-scoped repository reqs (v1 archive — owned by mxaccessgw today) |
| v1/reqs/MxAccessClientReqs.md | Galaxy-scoped MXAccess reqs (v1 archive — owned by mxaccessgw today) |
| reqs/StatusDashboardReqs.md | Pointer — superseded by Admin UI |
Implementation history (docs/v2/)
Design decisions + phase plans + execution notes. Load-bearing cross-references from the top-level docs:
- v2/plan.md — authoritative v2 vision doc + numbered decision log (referenced as "decision #N" elsewhere)
- v2/admin-ui.md — Admin UI spec
- v2/acl-design.md — data-plane ACL + permission-trie design (Phase 6.2)
- v2/config-db-schema.md — Config DB schema reference
- v2/driver-specs.md — per-driver addressing + quirks for every shipped protocol
- v2/dev-environment.md — dev-box bootstrap
- v2/test-data-sources.md — integration-test simulator matrix (includes the pinned libplctag
ab_serverversion for AB CIP tests) - v2/multi-host-dispatch.md — per-PLC circuit breakers (Phase 6.1 decision #144)
- v2/v2-release-readiness.md — release-readiness tracker
- v2/phase-7-status.md — Phase 7 reconciliation: what shipped vs. the plan, and the five remaining gaps
- v2/implementation/phase--.md — per-phase execution plans with exit-gate evidence
v1 archive
The v1 in-process MXAccess architecture (Galaxy.Host + Galaxy.Proxy + Galaxy.Shared, .NET 4.8 x86 COM, the OtOpcUaGalaxyHost Windows service) was retired in PR 7.2 (2026-04-30, commit ae7106d). Docs that described that shape are kept under v1/ as historical record — see v1/README.md for the index.