664ff75ee2
Read-only live gate on Elma presses Z35474 (TC3 3.1.4024) and Z34834 (TC2 2.11): - Sum-read: every chunk came back BadCommunicationError. Beckhoff's SumRead(IList<IgIoSumReadEntity>) ctor casts to IList<SumDataEntity>, which throws InvalidCastException for a List<> (only an array survives via covariance). The fake-client tests never built a real SumRead. New AdsTwinCATClient.CreateSumRead passes an array; TwinCATSumReadConstructionTests pins it (red on the List form) plus a falsifiability control on the library. After the fix: 59 tags, status identical everywhere, values identical on every non-moving tag, ~0.35-0.66 s vs ~2.7 s per poll; TC2 CE 2.11 answers sum reads. - An unexpected sum chunk failure now logs one Warning per device (it was invisible: the health message was overwritten by the next good read). - Diagnostics: TC2 has no TwinCAT_SystemInfoVarList; fall back to .SYSTEMINFO / .SYSTEMTASKINFOARR[1] once the TC3 name answers not-found (live: all six keys). - #612 browse: Flat verified on TC3 (10,770 leaves; VirtualTree 1,459 strict subset) — comment and docs updated, no load-mode option needed. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe