Closes the historian leg of Phase 7. Scripted alarm transitions now batch-flow
through the existing Galaxy.Host pipe + queue durably in a local SQLite store-
and-forward when Galaxy is the registered driver, instead of being dropped into
NullAlarmHistorianSink.
## GalaxyHistorianWriter (Driver.Galaxy.Proxy.Ipc)
IAlarmHistorianWriter implementation. Translates AlarmHistorianEvent →
HistorianAlarmEventDto (Stream D contract), batches via the existing
GalaxyIpcClient.CallAsync round-trip on MessageKind.HistorianAlarmEventRequest /
Response, maps per-event HistorianAlarmEventOutcomeDto bytes back to
HistorianWriteOutcome (Ack/RetryPlease/PermanentFail) so the SQLite drain
worker knows what to ack vs dead-letter vs retry. Empty-batch fast path.
Pipe-level transport faults (broken pipe, host crash) bubble up as
GalaxyIpcException which the SQLite sink's drain worker translates to
whole-batch RetryPlease per its catch contract.
## GalaxyProxyDriver implements IAlarmHistorianWriter
Marker interface lets Phase7Composer discover it via type check at compose
time. WriteBatchAsync delegates to a thin GalaxyHistorianWriter wrapping the
driver's existing _client. Throws InvalidOperationException if InitializeAsync
hasn't connected yet — the SQLite drain worker treats that as a transient
batch failure and retries.
## Phase7Composer.ResolveHistorianSink
Replaces the injected sink dep when any registered driver implements
IAlarmHistorianWriter. Constructs SqliteStoreAndForwardSink at
%ProgramData%/OtOpcUa/alarm-historian-queue.db (falls back to %TEMP% when
ProgramData unavailable, e.g. dev), starts the 2s drain timer, owns the sink
disposable for clean teardown. When no driver provides the writer, keeps the
NullAlarmHistorianSink wired by Program.cs (#246).
DisposeAsync now also disposes the owned SQLite sink in the right order:
bridge → engines → owned sink → injected fallback.
## Tests — 7 new GalaxyHistorianWriterMappingTests
ToDto round-trips every field; preserves null Comment; per-byte outcome enum
mapping (Ack / RetryPlease / PermanentFail) via [Theory]; unknown byte throws;
ctor null-guard. The IPC round-trip itself is covered by the live Host suite
(task #240) which constructs a real pipe.
Server.Phase7 tests: 34/34 still pass; Galaxy.Proxy tests: 25/25 (+7 = 32 total).
## Phase 7 production wiring chain — COMPLETE
- ✅#243 composition kernel
- ✅#245 scripted-alarm IReadable adapter
- ✅#244 driver bridge
- ✅#246 Program.cs wire-in
- ✅#247 this — Galaxy.Host historian writer + SQLite sink activation
What unblocks now: task #240 live OPC UA E2E smoke. With a Galaxy driver
registered, scripted alarm transitions flow end-to-end through the engine →
SQLite queue → drain worker → Galaxy.Host IPC → Aveva Historian alarm schema.