8b10d32728
A CNC can report duplicate sibling names — the wonder Makino returns two
axes both called AA — which made the Axes/ subtree untrustworthy: the
browser offered two identical folders the commit gate had to refuse, and
the poll loop's name-keyed snapshot cache let the second axis silently
overwrite the first. Spindles and servo loads had the same collision in
their own keying, plus a resolve-to-first-match on the spindle read path.
Scheme: every member of a collision set gets a 1-based occurrence-ordinal
suffix in slot order (AA_1, AA_2); unique names stay bare. Chosen over the
alternatives deliberately:
- Names, not slot numbers, stay the primary identity — the segment map is
re-derived from the live device each session, so a name-keyed path
follows the physical axis across config changes, where a slot-qualified
path would silently rebind on any axis-list shift and rename every axis
on every machine for one pathological CNC.
- The WHOLE collision set is suffixed: bare AA ceases to exist when
ambiguous, so a tag authored against it reads BadNodeIdUnknown rather
than one arbitrary axis's data — the #534/#540 silent-wrongness class.
- Occurrence ordinal, not absolute slot: inserting/removing an unrelated
axis never renames an existing duplicate pair. If the collision-set
membership itself changes, segments change on the next browse and stale
authored segments read Bad, never another axis's data.
One pure helper (FixedTreeNames.Disambiguate, collision-proof against
genuine names by suffix escalation) feeds FocasFixedTreeCache.AxisSegments
/ SpindleSegments, and the emitter, axis snapshot keys, servo-load keys
(cnc_rdsvmeter answers in slot order, so the k-th AA load belongs to the
k-th AA axis) and the spindle read resolution all consume those — they can
no longer disagree. The nameless-spindle S{n} fallback applies before
disambiguation so a fallback name colliding with a real one is handled
like any other duplicate.
Tests are red-first on the pre-fix driver (all five driver-level tests
fail on master's code): browse emits AA_1/AA_2 and no bare AA, each
duplicate reads its own position and servo load, duplicate spindles
resolve per slot, bare AA reads Bad. The wire half runs live against
focas-mock (duplicate names survive the managed wire parse and publish as
suffixed segments); the mock's dynamic store is name-keyed so the
distinct-values half stays with the offline tests. FOCAS 327/327,
integration 11/11, FOCAS.Cli 52, AdminUI 1113, ControlPlane 231.
Closes #548.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
345 lines
19 KiB
Markdown
345 lines
19 KiB
Markdown
# FOCAS Driver
|
||
|
||
Getting-started guide for the FANUC FOCAS2 driver. This is the short path — for
|
||
the exhaustive per-node mapping read [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md),
|
||
for the test-harness map read [FOCAS-Test-Fixture.md](FOCAS-Test-Fixture.md).
|
||
|
||
## What it talks to
|
||
|
||
FANUC CNCs (0i-D / 0i-F / 0i-MF / 0i-TF / 16i / 30i / 31i / 32i / Power Motion i)
|
||
over the proprietary FOCAS2 protocol on TCP port 8193. The wire is spoken
|
||
directly by the pure-managed [`Focas.Wire`](https://github.com/Ladder99/focas-mock)
|
||
client — no Fwlib64.dll, no P/Invoke, no out-of-process isolation needed.
|
||
|
||
OtOpcUa is **read-only** against FOCAS; all reads go over the native wire
|
||
protocol using the documented command IDs. Writes return
|
||
`BadNotWritable` by design.
|
||
|
||
> **Equipment tags are forced read-only (R2-11, migration note).** The equipment-tag parser
|
||
> (`FocasEquipmentTagParser`) now hard-codes `Writable: false` regardless of any authored
|
||
> `"writable": true` — previously such a tag advertised a writable node whose write always failed at
|
||
> the wire with `BadNotWritable`; now it fails one step earlier at the driver seam (same family of Bad
|
||
> status, no successful operation changes). The AdminUI FOCAS editor shows the Writable checkbox
|
||
> disabled/unchecked, and the deploy gate warns when a config requests `writable:true`. Additionally,
|
||
> equipment-tag references now run the same capability-matrix pre-flight authored tags get: a reference
|
||
> whose address violates the device series' matrix fails to resolve (`BadNodeIdUnknown`) instead of
|
||
> reaching the wire. Honour `writable` here once PMC writes ship in the wire client.
|
||
|
||
> **PDU version (v3 / FANUC 30i/31i).** The wire client **accepts inbound PDU versions `{1, 3}`**
|
||
> (`FocasWireProtocol`) while still emitting v1 on requests. Older controls + the docker mock answer
|
||
> v1; modern controls (Makino Pro 5 / FANUC **31i-B**) answer v3. **Validated live against a real
|
||
> 31i-B (`10.201.31.5`) 2026-06-25:** sysinfo, axis/spindle names, dynamic positions/feed/spindle,
|
||
> program/mode, **macros**, **timers** (8-byte payload is little-endian {minute, msec}), **PMC range**
|
||
> (request widened to the data-type byte width), **servo meters** (8-byte LOADELM stride + names from
|
||
> the 0x0089 block; load *scaling* still to be confirmed at commissioning), and **alarms** all read
|
||
> correctly. The driver `cnc_rddynamic2` poll is 1-based. **`cnc_rdparam` is unsupported on this
|
||
> control** — every request-framing variant returns `EW_FUNC` (likely a wrong v3 command id; needs a
|
||
> reference FWLIB trace). The Test-Connect probe now runs a real wire session (initiate + cnc_statinfo)
|
||
> instead of a bare TCP check. Full finding, captured wire bytes, validation results, and analysis:
|
||
> [`docs/plans/2026-06-25-focas-pdu-v3-30i-b-support.md`](../plans/2026-06-25-focas-pdu-v3-30i-b-support.md)
|
||
> + [`…-implementation-plan.md`](../plans/2026-06-25-focas-pdu-v3-implementation-plan.md).
|
||
> Capture tools: `scripts/focas/capture-initiate.py`, `scripts/focas/capture-v3.py`.
|
||
|
||
## Project split
|
||
|
||
| Project | Target | Role |
|
||
|---------|--------|------|
|
||
| `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS/` | net10.0 | In-process driver — hosts `WireFocasClient` which speaks FOCAS2 over TCP directly |
|
||
|
||
Previous `Driver.FOCAS.Host` / `Driver.FOCAS.Shared` Tier-C split has been
|
||
retired — the managed wire client removes the native-crash blast radius
|
||
that justified the out-of-process service.
|
||
|
||
## Minimum deployment
|
||
|
||
Register the driver instance in the main server's `appsettings.json`. No
|
||
separate service, no DLL deployment, no shared-secret handshake:
|
||
|
||
```jsonc
|
||
"Drivers": {
|
||
"focas-cnc-1": {
|
||
"Type": "FOCAS",
|
||
"Config": {
|
||
"Backend": "wire",
|
||
"Devices": [
|
||
{ "HostAddress": "focas://10.20.30.40:8193", "Series": "ThirtyOne_i" }
|
||
],
|
||
"Tags": [
|
||
{ "Name": "Mode", "DeviceHostAddress": "focas://10.20.30.40:8193",
|
||
"Address": "PARAM:3402", "DataType": "Int32", "Writable": false },
|
||
{ "Name": "SpndLoad", "DeviceHostAddress": "focas://10.20.30.40:8193",
|
||
"Address": "MACRO:500", "DataType": "Float64", "Writable": false }
|
||
]
|
||
}
|
||
}
|
||
}
|
||
```
|
||
|
||
The main server opens two TCP sockets per configured device and speaks the
|
||
FOCAS2 binary protocol directly. No local privileged components, no
|
||
platform bitness constraint — the driver runs on every host OtOpcUa runs
|
||
on.
|
||
|
||
## Address forms
|
||
|
||
| Form | Example | Meaning |
|
||
|------|---------|---------|
|
||
| `X0.0` / `R100` / `R100.3` | PMC bit or byte | Letter + number; optional `.bit` for bit access |
|
||
| `PARAM:1815` / `PARAM:1815/0` | CNC parameter | Number + optional axis index |
|
||
| `MACRO:500` | Custom macro variable | System / user macro variable number |
|
||
| `FIXED:Identity/SeriesNumber` | Fixed-tree field | A path into the [fixed node tree](#fixed-node-tree) — read-only |
|
||
|
||
The first three name a location the driver asks the CNC for on demand.
|
||
`FIXED:` does not: it names a field of the per-device fixed-tree snapshot the
|
||
driver's own poll loop already maintains, so a `FIXED:` read issues no wire
|
||
traffic. It exists because the fixed tree is the only part of the FOCAS surface
|
||
with no address of its own, and v3 publishes nodes only for authored tags — so
|
||
without a form to author, the fixed tree could not be published at all.
|
||
|
||
**An address never carries the device.** A tag's device comes from its raw-tag
|
||
Device row; an address that also named a host would be a second, conflicting
|
||
routing channel. This is worth stating because it is exactly what went wrong in
|
||
[#540](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/540): browse leaves
|
||
advertised `{deviceHost}/{path}` as their reference, the browse-commit wrote that
|
||
into the address, and every committed tag read `BadNodeIdUnknown` forever.
|
||
|
||
Addresses are validated against the per-device `Series` at `InitializeAsync` —
|
||
a config referencing a number outside the documented range for that series
|
||
fails at load time with an error message naming the limit. See
|
||
[`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) for the
|
||
authoritative range table. (`FIXED:` paths have no numeric range to check; a
|
||
path the machine does not expose reads `BadNodeIdUnknown`.)
|
||
|
||
An address the parser cannot read is rejected **when you author it** — by the
|
||
`/raw` tag modal, and by the deploy-time inspector for config arriving via CSV
|
||
import or the API. It is not a warning you can deploy past into a driver that
|
||
skips the tag at startup.
|
||
|
||
## Backend selection
|
||
|
||
The driver picks its client from `Config.Backend`:
|
||
|
||
| Value | Client | Use it for |
|
||
|-------|--------|------------|
|
||
| `wire` (default) | `WireFocasClient` | Production — pure-managed FOCAS2 over TCP |
|
||
| `unimplemented` / `none` / `stub` | `UnimplementedFocasClientFactory` | Scaffolding a DriverInstance row before the CNC endpoint is reachable |
|
||
|
||
**Fail-fast on `unimplemented` / `none` / `stub`:** a driver instance configured with any of
|
||
these backends now **faults immediately at `InitializeAsync`** with a clear error message rather
|
||
than reporting healthy and then failing on the first read/write/subscribe. The driver moves to
|
||
`Faulted` state and the error is visible on the Admin UI driver-status panel. This is intentional
|
||
— an operator who forgets to switch to `"wire"` before deploying to production sees a driver
|
||
fault at startup, not a phantom-healthy driver that silently rejects every request.
|
||
|
||
Previous backends (`fwlib`, `fwlib32`, `ipc`) have been retired along
|
||
with `Driver.FOCAS.Host` and the Fwlib P/Invoke path. Configs that still
|
||
reference them will throw at startup with a message pointing here.
|
||
|
||
## Capability surface
|
||
|
||
| Capability | Wire path | Notes |
|
||
|------------|-----------|-------|
|
||
| `IReadable` | `ReadAsync` → `cnc_rdpmcrng` / `cnc_rdparam` / `cnc_rdmacro` | One TCP request/response per read; `Focas.Wire` serializes requests on socket 2 internally |
|
||
| `IWritable` | returns `BadNotWritable` | OtOpcUa is read-only against FOCAS by design — no `cnc_wrparam` / `pmc_wrpmcrng` / `cnc_wrmacro` path is implemented |
|
||
| `ITagDiscovery` | `DiscoverAsync` | Emits `FOCAS/{device}/{tag}` folders per configured device |
|
||
| `ISubscribable` | polled via shared `PollGroupEngine` | FOCAS has no push model — subscriptions turn into per-tag polling groups |
|
||
| `IHostConnectivityProbe` | periodic `cnc_rdcncstat` | Probe cadence is `Probe.Interval`; transitions fire `OnHostStatusChanged` |
|
||
| `IPerCallHostResolver` | lookup in `_tagsByName` | Each call routes to the device of the referenced tag |
|
||
| `IAlarmSource` | polled `cnc_rdalmmsg2` via `FocasAlarmProjection` | Opt-in — set `AlarmProjection.Enabled=true`; diffs `(AlarmNumber, Type)` between ticks |
|
||
|
||
Ack is a no-op — FANUC clears alarms on its own once the underlying condition
|
||
resolves, so `AcknowledgeAsync` swallows the batch rather than surfacing
|
||
`BadNotSupported`.
|
||
|
||
## Fixed node tree
|
||
|
||
Enable a pre-defined hierarchy of CNC nodes populated automatically from
|
||
`cnc_sysinfo` + `cnc_rdaxisname` + `cnc_rddynamic2` + related FWLIB calls,
|
||
so operators get an out-of-the-box view of identity / axes / program /
|
||
timers without declaring per-address tags.
|
||
|
||
```jsonc
|
||
"Config": {
|
||
"Devices": [ ... ],
|
||
"Tags": [ ... ],
|
||
"FixedTree": {
|
||
"Enabled": true,
|
||
"PollInterval": "00:00:00.250", // fast — per-axis dynamic reads
|
||
"ProgramPollInterval": "00:00:01", // medium — program + mode changes
|
||
"TimerPollInterval": "00:00:30" // slow — cumulative counters
|
||
}
|
||
}
|
||
```
|
||
|
||
`Enabled` defaults to **false** so an upgrade does not grow nodes on configs
|
||
that never asked for them. You do not have to set it to use the tree: **authoring
|
||
any `FIXED:` tag arms the poll loop by itself**, because committing those tags
|
||
already says you want it. The flag remains the way to publish the tree without
|
||
authoring anything (and the browser turns it on for the duration of a browse).
|
||
|
||
### Authoring fixed-tree tags
|
||
|
||
Browse the device (`/raw` → device → **Browse device…**, or the tag modal's
|
||
**Browse machine**) and commit the leaves you want. Each leaf carries its own
|
||
`FIXED:` address, so the commit produces working tags with no editing. The
|
||
manual composer next to the browser covers PMC / `PARAM:` / `MACRO:` only —
|
||
fixed-tree paths are discovered from the machine, not composed from parts.
|
||
|
||
Two caveats worth knowing before you browse:
|
||
|
||
- **A real CNC can report duplicate sibling names, and they are disambiguated
|
||
automatically** (#548). One observed Makino returns two axes both called `AA`;
|
||
every member of such a collision set gets a 1-based occurrence suffix in slot
|
||
order — the tree offers `Axes/AA_1/` and `Axes/AA_2/`, each reading its own
|
||
axis — while unique names stay bare (`Axes/Y/`). The bare name of a duplicate
|
||
set deliberately does not resolve: a tag authored against `Axes/AA/…` on such
|
||
a machine reads `BadNodeIdUnknown` rather than one arbitrary axis's data. The
|
||
suffix counts occurrences of the *same* name, so adding an unrelated axis
|
||
never renames an existing pair — but if the collision-set membership itself
|
||
changes (a third `AA` appears, or one of two is removed), the segments change
|
||
on the next browse, and previously committed tags on the old segments read Bad
|
||
until re-committed. The same rule covers spindles.
|
||
- **Values are dated from the last answered poll, not from the read.** If a CNC
|
||
stops answering, its fixed-tree values go `BadCommunicationError` rather than
|
||
continuing to serve the last snapshot as `Good`; the budget is eight poll
|
||
cadences, floored at 30 s.
|
||
|
||
What gets populated (all under `FOCAS/{deviceHostAddress}/`, addressed as
|
||
`FIXED:{subtree}/{field}`):
|
||
|
||
| Subtree | Nodes | Source call |
|
||
|---------|-------|-------------|
|
||
| `Identity/` | `SeriesNumber`, `Version`, `MaxAxes`, `CncType`, `MtType`, `AxisCount` | `cnc_sysinfo` once at bootstrap |
|
||
| `Axes/{name}/` | `AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`, `ServoLoad` — one folder per discovered axis | `cnc_rdaxisname` once + `cnc_rddynamic2` + `cnc_rdsvmeter` per tick |
|
||
| `Axes/FeedRate/Actual`, `Axes/SpindleSpeed/Actual` | Current feed + spindle RPM | `cnc_rddynamic2` |
|
||
| `Spindle/{name}/` | `Load` (percentage), `MaxRpm` — one folder per discovered spindle | `cnc_rdspdlname` once + `cnc_rdspload` + `cnc_rdspmaxrpm` |
|
||
| `Program/` | `Name` (filename), `ONumber`, `Number`, `MainNumber`, `Sequence`, `BlockCount` | `cnc_exeprgname2` + `cnc_rdblkcount` + cached `cnc_rddynamic2` |
|
||
| `OperationMode/` | `Mode` (int), `ModeText` ("AUTO", "MDI", "EDIT", …) | `cnc_rdopmode` |
|
||
| `Timers/` | `PowerOnSeconds`, `OperatingSeconds`, `CuttingSeconds`, `CycleSeconds` | `cnc_rdtimer` × 4 |
|
||
|
||
### Per-series node suppression
|
||
|
||
The driver probes each optional call once at bootstrap. If the target CNC
|
||
returns `EW_FUNC` / `EW_NOOPT` / `EW_VERSION` on the wire, the
|
||
corresponding subtree is **not emitted** — the operator doesn't see nodes
|
||
that will only ever return `BadDeviceFailure`. Capability suppression
|
||
covers `Spindle/`, `Program/` + `OperationMode/`, `Timers/`, and
|
||
per-axis `ServoLoad` independently. Identity + `Axes/*` position reads
|
||
(which every Fanuc CNC supports) are always emitted.
|
||
|
||
Position values (`AbsolutePosition`, `MachinePosition`, `RelativePosition`, `DistanceToGo`)
|
||
are CNC-internal scaled integers exposed as `Float64` OPC UA nodes. The driver converts them
|
||
to engineering units using the per-device `PositionDecimalPlaces` config field (default `0`
|
||
= no scaling). When set to a positive integer *d*, each position value is divided by `10^d`
|
||
before publishing, so a CNC that reports millimetres × 1000 is corrected by setting
|
||
`PositionDecimalPlaces: 3`.
|
||
|
||
```jsonc
|
||
"Devices": [
|
||
{
|
||
"HostAddress": "focas://10.20.30.40:8193",
|
||
"Series": "ThirtyOne_i",
|
||
"PositionDecimalPlaces": 3 // 123456 → 123.456 mm
|
||
}
|
||
]
|
||
```
|
||
|
||
The driver now attempts to auto-scale each axis position using the CNC's `cnc_getfigure` figure when available; `PositionDecimalPlaces` is the **per-axis fallback** used only when the CNC reports no figure for that axis. **Caveat:** the managed `WireFocasClient` (FOCAS/2 Ethernet wire protocol) does not issue `cnc_getfigure` today, so on real hardware all axes still fall back to the manual `PositionDecimalPlaces` config field. Live auto-fetch is a follow-up requiring a `cnc_getfigure` command in `FocasWireClient`. Negative values from `PositionDecimalPlaces` are clamped to `0`.
|
||
|
||
**Follow-ups (known gaps, non-blocking):**
|
||
- No upper-bound clamp on the figure magnitude returned by the CNC — a misbehaving figure could overflow `Math.Pow`; a max-figure guard should be added.
|
||
- The negative-figure branch (falls back to manual `PositionDecimalPlaces`) is handled but not explicitly unit-tested.
|
||
|
||
**Still hand-authored**: `PARAM:6711`, `MACRO:500`, `R100` etc. — specific
|
||
numbers whose meaning is MTB-specific, and which no browse can discover. Those
|
||
go under the device folder alongside the fixed subtree.
|
||
|
||
## Alarm projection
|
||
|
||
Alarm surfacing is **disabled by default** because the polling cost is wasted
|
||
on sites that don't consume CNC alarms. Opt in per driver instance:
|
||
|
||
```jsonc
|
||
"Config": {
|
||
"Devices": [ ... ],
|
||
"Tags": [ ... ],
|
||
"AlarmProjection": {
|
||
"Enabled": true,
|
||
"PollInterval": "00:00:02"
|
||
}
|
||
}
|
||
```
|
||
|
||
Every alarm transition fires `OnAlarmEvent` with:
|
||
|
||
- `SourceNodeId` = the device host address (FOCAS has no per-node alarm model;
|
||
the CNC exposes a single flat active-alarm list per session)
|
||
- `ConditionId` = `"{host}#{Type}:{AlarmNumber}"`
|
||
- `AlarmType` = projected from FANUC's `ALM_TYPE_*` (e.g. `Overtravel`, `Servo`,
|
||
`Parameter`, `MacroAlarm`)
|
||
- `Severity` = Overtravel / Servo / PulseCode → `Critical`; Parameter / Macro
|
||
→ `Medium`; everything else → `High`
|
||
|
||
Cleared alarms fire a second event with `" (cleared)"` appended to the message
|
||
so downstream consumers can ignore the clear if they only care about raises.
|
||
|
||
## Handle recycling
|
||
|
||
FANUC CNCs have a finite FWLIB handle pool (~5–10 concurrent connections) and
|
||
certain series have documented handle-leak bugs that manifest after long uptime.
|
||
The driver can proactively close + reopen each device's session on a cadence to
|
||
release its slot back to the pool:
|
||
|
||
```jsonc
|
||
"Config": {
|
||
"Devices": [ ... ],
|
||
"HandleRecycle": {
|
||
"Enabled": true,
|
||
"Interval": "01:00:00"
|
||
}
|
||
}
|
||
```
|
||
|
||
Disabled by default — a healthy CNC + driver doesn't need it. Enable when field
|
||
experience shows handle exhaustion. Typical tuning: 30 min for sites running
|
||
multiple OtOpcUa instances against the same CNC (they share the pool); 6 h for a
|
||
single-client deployment. Reads / writes during recycle simply wait for the
|
||
reconnect rather than failing — worst case, an operator sees a brief read
|
||
latency spike once per cadence.
|
||
|
||
## Testing
|
||
|
||
- **Unit tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests/` cover the
|
||
driver surface via `FakeFocasClient`. Includes the alarm-projection raise /
|
||
clear diffing tests.
|
||
- **Integration tests** — `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.IntegrationTests/`
|
||
hold the Docker simulator scaffold; see
|
||
[`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md)
|
||
for what the simulator emits vs. real CNC behaviour.
|
||
- **E2E script** — `scripts/e2e/test-focas.ps1` stages Host + Proxy + a real
|
||
CNC (or the simulator) and exercises connect → read → write → subscribe
|
||
round-trips. See [`docs/drivers/FOCAS-Test-Fixture.md`](FOCAS-Test-Fixture.md)
|
||
for the coverage map.
|
||
|
||
## Troubleshooting
|
||
|
||
| Symptom | Likely cause | Fix |
|
||
|---------|--------------|-----|
|
||
| Driver faults immediately at startup with "unimplemented" in the error | `Backend` is `"unimplemented"` / `"none"` / `"stub"` | Change `Backend` to `"wire"` and supply the real CNC endpoint in `Devices[]` |
|
||
| `BadCommunicationError` on every read | CNC unreachable on TCP:8193 | Check firewall / LAN reachability; FOCAS Ethernet option must be licensed on the CNC side |
|
||
| Every read returns `BadNotWritable` on writes | Expected — OtOpcUa is read-only against FOCAS | If you actually need writes, open a feature request — the driver's managed wire client doesn't expose the write commands |
|
||
| `BadOutOfRange` on reads for a macro/parameter | Config address outside the declared `Series` range | Check `docs/v2/focas-version-matrix.md` — either fix the address or widen the `Series` |
|
||
| Alarm events never fire | `AlarmProjection.Enabled` left at default (false) | Set it to `true` in the driver config |
|
||
| Axis position values seem 1000× too large | `PositionDecimalPlaces` not set | Add `"PositionDecimalPlaces": 3` (or the MTB-specific value) to the device entry in `Devices[]` |
|
||
|
||
## Further reading
|
||
|
||
- [`docs/v2/driver-specs.md §7`](../v2/driver-specs.md) — full OPC UA node
|
||
mapping, pre-defined tag set, per-API notes
|
||
- [`docs/v2/focas-version-matrix.md`](../v2/focas-version-matrix.md) —
|
||
per-series macro / parameter / PMC range table
|
||
- [`docs/v2/implementation/focas-wire-protocol.md`](../v2/implementation/focas-wire-protocol.md)
|
||
— captured FOCAS2 wire semantics (magic prefix, handshake, command-id table)
|
||
- [upstream `Focas.Wire`](https://github.com/Ladder99/focas-mock/tree/main/dotnet/Focas.Wire)
|
||
— the managed client implementation OtOpcUa consumes as a NuGet dependency
|