Joseph Doherty 1d3544f18e S7 integration fixture — python-snap7 server closes the wire-level coverage gap (#216) + per-driver fixture coverage docs for every driver in the fleet. Closes #216. Two shipments in one PR because the docs landed as I surveyed each driver's fixture + the S7 work is the first wire-level-gap closer pulled from that survey.
S7 integration — AbCip/Modbus already have real-simulator integration suites; S7 had zero wire-level coverage despite being a Tier-A driver (all unit tests mocked IS7Client). Picked python-snap7's `snap7.server.Server` over raw Snap7 C library because `pip install` beats per-OS binary-pin maintenance, the package ships a Python __main__ shim that mirrors our existing pymodbus serve.ps1 + *.json pattern structurally, and the python-snap7 project is actively maintained. New project `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/` with four moving parts: (a) `Snap7ServerFixture` — collection-scoped TCP probe on `localhost:1102` that sets `SkipReason` when the simulator's not running, matching the `ModbusSimulatorFixture` shape one directory over (same S7_SIM_ENDPOINT env var override convention for pointing at a real S7 CPU on port 102); (b) `PythonSnap7/` — `serve.ps1` wrapper + `server.py` shim + `s7_1500.json` seed profile + `README.md` documenting install / run / known limitations; (c) `S7_1500/S7_1500Profile.cs` — driver-side `S7DriverOptions` whose tag addresses map 1:1 to the JSON profile's seed offsets (DB1.DBW0 u16, DB1.DBW10 i16, DB1.DBD20 i32, DB1.DBD30 f32, DB1.DBX50.3 bool, DB1.DBW100 scratch); (d) `S7_1500SmokeTests` — three tests proving typed reads + write-then-read round-trip work through real S7netplus + real ISO-on-TCP + real snap7 server. Picked port 1102 default instead of S7-standard 102 because 102 is privileged on Linux + triggers Windows Firewall prompt; S7netplus 0.20 has a 5-arg `Plc(CpuType, host, port, rack, slot)` ctor that lets the driver honour `S7DriverOptions.Port`, but the existing driver code called the 4-arg overload + silently hardcoded 102. One-line driver fix (S7Driver.cs:87) threads `_options.Port` through — the S7 unit suite (58/58) still passes unchanged because every unit test uses a fake IS7Client that never sees the real ctor. Server seed-type matrix in `server.py` covers u8 / i8 / u16 / i16 / u32 / i32 / f32 / bool-with-bit / ascii (S7 STRING with max_len header). register_area takes the SrvArea enum value, not the string name — a 15-minute debug after the first test run caught that; documented inline.

Per-driver test-fixture coverage docs — eight new files in `docs/drivers/` laying out what each driver's harness actually benchmarks vs. what's trusted from field deployments. Pattern mirrors the AbServer-Test-Fixture.md doc that shipped earlier in this arc: TL;DR → What the fixture is → What it actually covers → What it does NOT cover → When-to-trust table → Follow-up candidates → Key files. Ugly truth the survey made visible: Galaxy + Modbus + (now) S7 + AB CIP have real wire-level coverage; AB Legacy / TwinCAT / FOCAS / OpcUaClient are still contract-only because their libraries ship no fake + no open-source simulator exists (AB Legacy PCCC), no public simulator exists (FOCAS), the vendor SDK has no in-process fake (TwinCAT/ADS.NET), or the test wiring just hasn't happened yet (OpcUaClient could trivially loopback against this repo's own server — flagged as #215). Each doc names the specific follow-up route: Snap7 server for S7 (done), TwinCAT 3 developer-runtime auto-restart for TwinCAT, Tier-C out-of-process Host for FOCAS, lab rigs for AB Legacy + hardware-gated bits of the others. `docs/drivers/README.md` gains a coverage-map section linking all eight. Tracking tasks #215-#222 filed for each PR-able follow-up.

Build clean (driver + integration project + docs); S7.Tests 58/58 (unchanged); S7.IntegrationTests 3/3 (new, verified end-to-end against a live python-snap7 server: `driver_reads_seeded_u16_through_real_S7comm`, `driver_reads_seeded_typed_batch`, `driver_write_then_read_round_trip_on_scratch_word`). Next fixture follow-up is #215 (OpcUaClient loopback against own server) — highest ROI of the remaining set, zero external deps.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 11:29:15 -04:00
..
Phase 3 PR 63 -- S7AddressParser for DB/M/I/Q/T/C address strings. Adds S7AddressParser + S7ParsedAddress + S7Area + S7Size to the Driver.S7 project. Grammar follows driver-specs.md \u00A75 + Siemens TIA Portal / STEP 7 Classic convention: (1) Data blocks: DB{n}.DB{X|B|W|D}{offset}[.bit] where X=bit (requires .bit suffix 0-7), B=byte, W=word (16-bit), D=dword (32-bit). (2) Merkers: MB{n}, MW{n}, MD{n}, or M{n}.{bit} for bit access. (3) Inputs + Outputs: same {B|W|D} prefix or {n}.{bit} pattern as M. (4) Timers: T{n}. (5) Counters: C{n}. Output is an immutable S7ParsedAddress record struct with Area (DataBlock / Memory / Input / Output / Timer / Counter), DbNumber (only meaningful for DataBlock), Size (Bit / Byte / Word / DWord), ByteOffset (also timer/counter number when Area is Timer/Counter), BitOffset (0-7 for Size=Bit; 0 otherwise). Case-insensitive via ToUpperInvariant, whitespace trimmed on entry. Parse throws FormatException with the offending input echoed in the message; TryParse returns bool for config-validation callers that can't afford exceptions (e.g. Admin UI tag-editor live validation). Strict rejection policy -- 16 garbage cases covered in the theory test: empty/whitespace input, unknown area letter (Z0), DB without number/tail, DB bit size without .bit suffix, bit offset 8+, word/dword with .bit suffix, DB number 0 (must be >=1), non-numeric DB number, unknown size letter (Q), M without offset, M bit access without .bit, bit 8, negative offset, non-digit offset, non-numeric timer. Strict rejection surfaces config errors at driver-init time rather than as BadInternalError on every Read against the bad tag. No driver code wires through yet -- PR 64 is where IReadable/IWritable consume S7ParsedAddress and translate into S7netplus Plc.ReadAsync calls (the S7.Net address grammar is a strict subset of what we accept, and the parser's S7ParsedAddress is the bridge). Unit tests (S7AddressParserTests, 50 facts): parse-valid theories for DB/M/I/Q/T/C covering all size variants + edge bit offsets 0 and 7; case-insensitive + whitespace-trim theory; reject-invalid theory with 16 garbage cases; TryParse round-trip for valid and invalid inputs. 50/50 pass, dotnet build clean.
2026-04-19 00:06:24 -04:00
Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.