Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.

This commit is contained in:
Joseph Doherty
2026-04-19 00:03:09 -04:00
parent 8150177296
commit 0575280a3b
6 changed files with 357 additions and 0 deletions

View File

@@ -9,6 +9,7 @@
<Project Path="src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ZB.MOM.WW.OtOpcUa.Driver.Modbus.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Driver.S7/ZB.MOM.WW.OtOpcUa.Driver.S7.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Client.Shared/ZB.MOM.WW.OtOpcUa.Client.Shared.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Client.CLI/ZB.MOM.WW.OtOpcUa.Client.CLI.csproj"/>
<Project Path="src/ZB.MOM.WW.OtOpcUa.Client.UI/ZB.MOM.WW.OtOpcUa.Client.UI.csproj"/>
@@ -26,6 +27,7 @@
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Client.Shared.Tests/ZB.MOM.WW.OtOpcUa.Client.Shared.Tests.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Client.CLI.Tests/ZB.MOM.WW.OtOpcUa.Client.CLI.Tests.csproj"/>
<Project Path="tests/ZB.MOM.WW.OtOpcUa.Client.UI.Tests/ZB.MOM.WW.OtOpcUa.Client.UI.Tests.csproj"/>

View File

@@ -0,0 +1,119 @@
using S7.Net;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
/// <summary>
/// Siemens S7 native driver — speaks S7comm over ISO-on-TCP (port 102) via the S7netplus
/// library. First implementation of <see cref="IDriver"/> for an in-process .NET Standard
/// PLC protocol that is NOT Modbus, validating that the v2 driver-capability interfaces
/// generalize beyond Modbus + Galaxy.
/// </summary>
/// <remarks>
/// <para>
/// PR 62 ships the scaffold: <see cref="IDriver"/> only (Initialize / Reinitialize /
/// Shutdown / GetHealth). <see cref="ITagDiscovery"/>, <see cref="IReadable"/>,
/// <see cref="IWritable"/>, <see cref="ISubscribable"/>, <see cref="IHostConnectivityProbe"/>
/// land in PRs 63-65 once the address parser (PR 63) is in place.
/// </para>
/// <para>
/// <b>Single-connection policy</b>: S7netplus documented pattern is one
/// <c>Plc</c> instance per PLC, serialized with a <see cref="SemaphoreSlim"/>.
/// Parallelising reads against a single S7 CPU doesn't help — the CPU scans the
/// communication mailbox at most once per cycle (2-10 ms) and queues concurrent
/// requests wire-side anyway. Multiple client-side connections just waste the CPU's
/// 8-64 connection-resource budget.
/// </para>
/// </remarks>
public sealed class S7Driver(S7DriverOptions options, string driverInstanceId)
: IDriver, IDisposable, IAsyncDisposable
{
private readonly S7DriverOptions _options = options;
private readonly SemaphoreSlim _gate = new(1, 1);
/// <summary>
/// Per-connection gate. Internal so PRs 63-65 (read/write/subscribe) can serialize on
/// the same semaphore without exposing it publicly. Single-connection-per-PLC is a
/// hard requirement of S7netplus — see class remarks.
/// </summary>
internal SemaphoreSlim Gate => _gate;
/// <summary>
/// Active S7.Net PLC connection. Null until <see cref="InitializeAsync"/> returns; null
/// after <see cref="ShutdownAsync"/>. Read-only outside this class; PR 64's Read/Write
/// will take the <see cref="_gate"/> before touching it.
/// </summary>
internal Plc? Plc { get; private set; }
private DriverHealth _health = new(DriverState.Unknown, null, null);
private bool _disposed;
public string DriverInstanceId => driverInstanceId;
public string DriverType => "S7";
public async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
{
_health = new DriverHealth(DriverState.Initializing, null, null);
try
{
var plc = new Plc(_options.CpuType, _options.Host, _options.Rack, _options.Slot);
// S7netplus writes timeouts into the underlying TcpClient via Plc.WriteTimeout /
// Plc.ReadTimeout (milliseconds). Set before OpenAsync so the handshake itself
// honours the bound.
plc.WriteTimeout = (int)_options.Timeout.TotalMilliseconds;
plc.ReadTimeout = (int)_options.Timeout.TotalMilliseconds;
using var cts = CancellationTokenSource.CreateLinkedTokenSource(cancellationToken);
cts.CancelAfter(_options.Timeout);
await plc.OpenAsync(cts.Token).ConfigureAwait(false);
Plc = plc;
_health = new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null);
}
catch (Exception ex)
{
// Clean up a partially-constructed Plc so a retry from the caller doesn't leak
// the TcpClient. S7netplus's Close() is best-effort and idempotent.
try { Plc?.Close(); } catch { }
Plc = null;
_health = new DriverHealth(DriverState.Faulted, null, ex.Message);
throw;
}
}
public async Task ReinitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
{
await ShutdownAsync(cancellationToken).ConfigureAwait(false);
await InitializeAsync(driverConfigJson, cancellationToken).ConfigureAwait(false);
}
public Task ShutdownAsync(CancellationToken cancellationToken)
{
try { Plc?.Close(); } catch { /* best-effort — tearing down anyway */ }
Plc = null;
_health = new DriverHealth(DriverState.Unknown, _health.LastSuccessfulRead, null);
return Task.CompletedTask;
}
public DriverHealth GetHealth() => _health;
/// <summary>
/// Approximate memory footprint. The Plc instance + one 240-960 byte PDU buffer is
/// under 4 KB; return 0 because the <see cref="IDriver"/> contract asks for a
/// driver-attributable growth number and S7.Net doesn't expose one.
/// </summary>
public long GetMemoryFootprint() => 0;
public Task FlushOptionalCachesAsync(CancellationToken cancellationToken) => Task.CompletedTask;
public void Dispose() => DisposeAsync().AsTask().GetAwaiter().GetResult();
public async ValueTask DisposeAsync()
{
if (_disposed) return;
_disposed = true;
try { await ShutdownAsync(CancellationToken.None).ConfigureAwait(false); }
catch { /* disposal is best-effort */ }
_gate.Dispose();
}
}

View File

@@ -0,0 +1,112 @@
using S7NetCpuType = global::S7.Net.CpuType;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
/// <summary>
/// Siemens S7 native (S7comm / ISO-on-TCP port 102) driver configuration. Bound from the
/// driver's <c>DriverConfig</c> JSON at <c>DriverHost.RegisterAsync</c>. Unlike the Modbus
/// driver the S7 driver uses the PLC's *native* protocol — port 102 ISO-on-TCP rather
/// than Modbus's 502, and S7-specific area codes (DB, M, I, Q) rather than holding-
/// register / coil tables.
/// </summary>
/// <remarks>
/// <para>
/// The driver requires <b>PUT/GET communication enabled</b> in the TIA Portal
/// hardware config for S7-1200/1500. The factory default disables PUT/GET access,
/// so a driver configured against a freshly-flashed CPU will see a hard error
/// (S7.Net surfaces it as <c>Plc.ReadAsync</c> returning <c>ErrorCode.Accessing</c>).
/// The driver maps that specifically to <c>BadNotSupported</c> and flags it as a
/// configuration alert rather than a transient fault — blind Polly retry is wasted
/// effort when the PLC will keep refusing every request.
/// </para>
/// <para>
/// See <c>docs/v2/driver-specs.md</c> §5 for the full specification.
/// </para>
/// </remarks>
public sealed class S7DriverOptions
{
/// <summary>PLC IP address or hostname.</summary>
public string Host { get; init; } = "127.0.0.1";
/// <summary>TCP port. ISO-on-TCP is 102 on every S7 model; override only for unusual NAT setups.</summary>
public int Port { get; init; } = 102;
/// <summary>
/// CPU family. Determines the ISO-TSAP slot byte that S7.Net uses during connection
/// setup — pick the family that matches the target PLC exactly.
/// </summary>
public S7NetCpuType CpuType { get; init; } = S7NetCpuType.S71500;
/// <summary>
/// Hardware rack number. Almost always 0; relevant only for distributed S7-400 racks
/// with multiple CPUs.
/// </summary>
public short Rack { get; init; } = 0;
/// <summary>
/// CPU slot. Conventions per family: S7-300 = slot 2, S7-400 = slot 2 or 3,
/// S7-1200 / S7-1500 = slot 0 (onboard PN). S7.Net uses this to build the remote
/// TSAP. Wrong slot → connection refused during handshake.
/// </summary>
public short Slot { get; init; } = 0;
/// <summary>Connect + per-operation timeout.</summary>
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(5);
/// <summary>Pre-declared tag map. S7 has a symbol-table protocol but S7.Net does not expose it, so the driver operates off a static tag list configured per-site. Address grammar documented in S7AddressParser (PR 63).</summary>
public IReadOnlyList<S7TagDefinition> Tags { get; init; } = [];
/// <summary>
/// Background connectivity-probe settings. When enabled, the driver runs a tick loop
/// that issues a cheap read against <see cref="S7ProbeOptions.ProbeAddress"/> every
/// <see cref="S7ProbeOptions.Interval"/> and raises <c>OnHostStatusChanged</c> on
/// Running ↔ Stopped transitions.
/// </summary>
public S7ProbeOptions Probe { get; init; } = new();
}
public sealed class S7ProbeOptions
{
public bool Enabled { get; init; } = true;
public TimeSpan Interval { get; init; } = TimeSpan.FromSeconds(5);
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
/// <summary>
/// Address to probe for liveness. DB1.DBW0 is the convention if the PLC project
/// reserves a small fingerprint DB for health checks (per <c>docs/v2/s7.md</c>);
/// if not, pick any valid Merker word like <c>MW0</c>.
/// </summary>
public string ProbeAddress { get; init; } = "MW0";
}
/// <summary>
/// One S7 variable as exposed by the driver. Addresses use S7.Net syntax — see
/// <c>S7AddressParser</c> (PR 63) for the grammar.
/// </summary>
/// <param name="Name">Tag name; OPC UA browse name + driver full reference.</param>
/// <param name="Address">S7 address string, e.g. <c>DB1.DBW0</c>, <c>M0.0</c>, <c>I0.0</c>, <c>QD4</c>. Grammar documented in <c>S7AddressParser</c> (PR 63).</param>
/// <param name="DataType">Logical data type — drives the underlying S7.Net read/write width.</param>
/// <param name="Writable">When true the driver accepts writes for this tag.</param>
/// <param name="StringLength">For <c>DataType = String</c>: S7-string max length. Default 254 (S7 max).</param>
public sealed record S7TagDefinition(
string Name,
string Address,
S7DataType DataType,
bool Writable = true,
int StringLength = 254);
public enum S7DataType
{
Bool,
Byte,
Int16,
UInt16,
Int32,
UInt32,
Int64,
UInt64,
Float32,
Float64,
String,
DateTime,
}

View File

@@ -0,0 +1,27 @@
<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<TargetFramework>net10.0</TargetFramework>
<Nullable>enable</Nullable>
<ImplicitUsings>enable</ImplicitUsings>
<LangVersion>latest</LangVersion>
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
<GenerateDocumentationFile>true</GenerateDocumentationFile>
<NoWarn>$(NoWarn);CS1591</NoWarn>
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.S7</RootNamespace>
<AssemblyName>ZB.MOM.WW.OtOpcUa.Driver.S7</AssemblyName>
</PropertyGroup>
<ItemGroup>
<ProjectReference Include="..\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
</ItemGroup>
<ItemGroup>
<PackageReference Include="S7netplus" Version="0.20.0"/>
</ItemGroup>
<ItemGroup>
<InternalsVisibleTo Include="ZB.MOM.WW.OtOpcUa.Driver.S7.Tests"/>
</ItemGroup>
</Project>

View File

@@ -0,0 +1,66 @@
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Tests;
/// <summary>
/// Scaffold-level tests that don't need a live S7 PLC — exercise driver lifecycle shape,
/// default option values, and failure-mode transitions. PR 64 adds IReadable/IWritable
/// tests against a mock-server, PR 65 adds discovery + subscribe.
/// </summary>
[Trait("Category", "Unit")]
public sealed class S7DriverScaffoldTests
{
[Fact]
public void Default_options_target_S7_1500_slot_0_on_port_102()
{
var opts = new S7DriverOptions();
opts.Port.ShouldBe(102, "ISO-on-TCP is always 102 for S7; documented in driver-specs.md §5");
opts.CpuType.ShouldBe(global::S7.Net.CpuType.S71500);
opts.Rack.ShouldBe((short)0);
opts.Slot.ShouldBe((short)0, "S7-1200/1500 onboard PN ports are slot 0 by convention");
}
[Fact]
public void Default_probe_interval_is_reasonable_for_S7_scan_cycle()
{
// S7 PLCs scan 2-10 ms but comms mailbox typically processed once per scan.
// 5 s default probe is lightweight — ~0.001% of comms budget.
new S7ProbeOptions().Interval.ShouldBe(TimeSpan.FromSeconds(5));
}
[Fact]
public void Tag_definition_defaults_to_writable_with_S7_max_string_length()
{
var tag = new S7TagDefinition("T", "DB1.DBW0", S7DataType.Int16);
tag.Writable.ShouldBeTrue();
tag.StringLength.ShouldBe(254, "S7 STRING type max length is 254 chars");
}
[Fact]
public void Driver_instance_reports_type_and_id_before_connect()
{
var opts = new S7DriverOptions { Host = "127.0.0.1" };
using var drv = new S7Driver(opts, "s7-test");
drv.DriverType.ShouldBe("S7");
drv.DriverInstanceId.ShouldBe("s7-test");
drv.GetHealth().State.ShouldBe(DriverState.Unknown, "health starts Unknown until InitializeAsync runs");
}
[Fact]
public async Task Initialize_against_unreachable_host_transitions_to_Faulted_and_throws()
{
// Pick an RFC 5737 reserved-for-documentation IP so the connect attempt fails fast
// (no DNS mismatch, no accidental traffic to a real PLC).
var opts = new S7DriverOptions { Host = "192.0.2.1", Timeout = TimeSpan.FromMilliseconds(250) };
using var drv = new S7Driver(opts, "s7-unreach");
await Should.ThrowAsync<Exception>(async () =>
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken));
var health = drv.GetHealth();
health.State.ShouldBe(DriverState.Faulted, "unreachable host must flip the driver to Faulted so operators see it");
health.LastError.ShouldNotBeNull();
}
}

View File

@@ -0,0 +1,31 @@
<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<TargetFramework>net10.0</TargetFramework>
<Nullable>enable</Nullable>
<ImplicitUsings>enable</ImplicitUsings>
<IsPackable>false</IsPackable>
<IsTestProject>true</IsTestProject>
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.S7.Tests</RootNamespace>
</PropertyGroup>
<ItemGroup>
<PackageReference Include="xunit.v3" Version="1.1.0"/>
<PackageReference Include="Shouldly" Version="4.3.0"/>
<PackageReference Include="Microsoft.NET.Test.Sdk" Version="17.12.0"/>
<PackageReference Include="xunit.runner.visualstudio" Version="3.0.2">
<PrivateAssets>all</PrivateAssets>
<IncludeAssets>runtime; build; native; contentfiles; analyzers; buildtransitive</IncludeAssets>
</PackageReference>
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\src\ZB.MOM.WW.OtOpcUa.Driver.S7\ZB.MOM.WW.OtOpcUa.Driver.S7.csproj"/>
</ItemGroup>
<ItemGroup>
<NuGetAuditSuppress Include="https://github.com/advisories/GHSA-37gx-xxp4-5rgx"/>
<NuGetAuditSuppress Include="https://github.com/advisories/GHSA-w3x6-4m5h-cxqf"/>
</ItemGroup>
</Project>