Files
lmxopcua/tests
Joseph Doherty b548cc46e6 perf(mtconnect): read through the live pump index; instance-id check on the /current fallback (R06:T-4, T-2)
- T-4: every ReadAsync batch fetched and parsed the whole device /current and
  built a fresh index even while the /sample pump held a live one. A read is now
  answered from the pump's index (read only - the pump stays its single writer)
  while the current-generation pump is running, has delivered since it started and
  is not degraded; /current stays the fallback, and its per-batch index is built
  over a tag map frozen once per binding instead of per call. A served read clears
  the read-path degradation a failed /current left.
- T-2: the /current fallback checks the answer's instanceId; a change (an Agent
  restart seen by a browse-only driver) drops the cached /probe model and raises
  rediscovery once per distinct id, only while the read's session is still installed.
- The pump also acts on no verdict (Degrade / latch) once its session generation
  is gone, so an abandoned pump cannot write health over the new session (T-1 follow-through).

Refs #743

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:39:58 -04:00
..