Joseph Doherty a68593e714 feat(sql): named-query tag model — read-only SELECTs declared on the driver (lmxopcua#753)
SqlTagModel.Query (design §5.4) is now served end to end instead of refused.
The driver config declares `queries` (name -> sql, params, maxRows); a tag names
the query, the result `column` it reads and optionally a `rowKey` picking its row.

- Parser/deploy gate: query + column required, rowKey all-or-nothing; Inspect
  explains each refusal. Table is not read for this model.
- SqlReadOnlyStatement: single SELECT/WITH only, no data/schema-changing keyword
  outside literals/comments (refuses SELECT INTO, FOR UPDATE, DML CTEs). Shared by
  the factory and the AdminUI driver form (SqlNamedQueryRules.Describe), so the
  form refuses what the driver refuses. One bad entry fails the driver.
- Parameters are always bound; the factory refuses a declared parameter whose
  dialect marker the statement never uses.
- Reader: one execution per query per poll, inside a transaction that is always
  rolled back; result columns matched exact-then-unique-CI; no row -> BadNoData,
  ambiguous row / missing column / over maxRows -> BadConfigurationError.
- Catalog gate passes Query tags through (nothing is quoted into SQL); a
  Query-only driver skips the catalog load. A tag naming an undeclared query is
  skipped with the reason on /hosts.
- AdminUI: typed editor offers Query (query/column/rowKey); driver form edits
  `queries` as JSON and keeps the last valid set on a typo.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV