Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Server.Tests/EquipmentNamespaceContentLoaderTests.cs
Joseph Doherty a29828e41e EquipmentNamespaceContentLoader — Config-DB loader that fills the (driverInstanceId, generationId) shape the walker wire-in from PR #155 consumes. Narrow follow-up to PR #155: the ctor plumbing on OpcUaApplicationHost already takes a Func<string, EquipmentNamespaceContent?>? lookup; this PR lands the loader that will back that lookup against the central Config DB at SealedBootstrap time. DI composition in Program.cs is a separate structural PR because it needs the generation-resolve chain restructured to run before OpcUaApplicationHost construction — this one just lands the loader + unit tests so the wiring PR reduces to one factory lambda. Loader scope is one driver instance at one generation: joins Equipment filtered by (DriverInstanceId == driver, GenerationId == gen, Enabled) first, then UnsLines reachable from those Equipment rows, then UnsAreas reachable from those lines, then Tags filtered by (DriverInstanceId == driver, GenerationId == gen). Returns null when the driver has no Equipment at the supplied generation — the wire-in's null-check treats that as "skip the walker; let DiscoverAsync own the whole address space" which is the correct backward-compat behavior for non-Equipment-kind drivers (Modbus / AB CIP / TwinCAT / FOCAS whose namespace-kind is native per decisions #116-#121). Only loads the UNS branches that actually host this driver's Equipment — skips pulling unrelated UNS folders from other drivers' regions of the cluster by deriving lineIds/areaIds from the filtered Equipment set rather than reloading the full UNS tree. Enabled=false Equipment are skipped at the query level so a decommissioned machine doesn't produce a phantom browse folder — Admin still sees it in the diff view via the regular Config-DB queries but the walker's browse output reflects the operational fleet. AsNoTracking on every query because the bootstrap flow is read-only + the result is handed off to a pure-function walker immediately; change tracking would pin rows in the DbContext for the full server lifetime with no corresponding write path. Five new EquipmentNamespaceContentLoaderTests using InMemoryDatabase: (a) null result when driver has no Equipment; (b) baseline happy-path loads the full shape correctly; (c) other driver's rows at the same generation don't leak into this driver's result (per-driver scope contract); (d) same-driver rows at a different generation are skipped (per-generation scope contract per decision #148); (e) Enabled=false Equipment are skipped. Server project builds 0 errors; Server.Tests 186/186 (was 181, +5 new loader tests). Once the wiring PR lands the factory lambda in Program.cs the loader closes over the SealedBootstrap-resolved generationId + the lookup delegate delegates to LoadAsync via IServiceScopeFactory — a one-line composition, no ctor-signature churn on OpcUaApplicationHost because PR #155 already established the seam.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 03:19:45 -04:00

6.4 KiB