9cad9ed0fc
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
68 lines
2.8 KiB
C#
68 lines
2.8 KiB
C#
using CliFx.Attributes;
|
|
using CliFx.Infrastructure;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Commands;
|
|
|
|
/// <summary>
|
|
/// Read one FOCAS address (PMC R/G/F file, parameter, macro, axis register).
|
|
/// </summary>
|
|
[Command("read", Description = "Read a single FOCAS address.")]
|
|
public sealed class ReadCommand : FocasCommandBase
|
|
{
|
|
/// <summary>Gets the FOCAS address to read.</summary>
|
|
[CommandOption("address", 'a', Description =
|
|
"FOCAS address. Examples: R100 (PMC R-file word); X0.0 (PMC X-bit); " +
|
|
"PARAM:1815/0 (parameter 1815, axis 0); MACRO:500 (macro variable 500).",
|
|
IsRequired = true)]
|
|
public string Address { get; init; } = default!;
|
|
|
|
/// <summary>Gets the data type to interpret the address as.</summary>
|
|
[CommandOption("type", 't', Description =
|
|
"Bit / Byte / Int16 / Int32 / Float32 / Float64 / String (default Int16).")]
|
|
public FocasDataType DataType { get; init; } = FocasDataType.Int16;
|
|
|
|
/// <inheritdoc />
|
|
public override async ValueTask ExecuteAsync(IConsole console)
|
|
{
|
|
ConfigureLogging();
|
|
// Validate numeric option ranges before any driver work.
|
|
ValidateOptions();
|
|
var ct = console.RegisterCancellationHandler();
|
|
|
|
var tagName = SynthesiseTagName(Address, DataType);
|
|
var tag = new FocasTagDefinition(
|
|
Name: tagName,
|
|
DeviceHostAddress: HostAddress,
|
|
Address: Address,
|
|
DataType: DataType,
|
|
Writable: false);
|
|
var options = BuildOptions([tag]);
|
|
|
|
// `await using` is the sole disposal mechanism — FocasDriver.DisposeAsync
|
|
// already invokes ShutdownAsync, so a redundant explicit ShutdownAsync(CancellationToken.None)
|
|
// in a finally block ran shutdown twice. The await-using on the next line is enough.
|
|
await using var driver = new FocasDriver(options, DriverInstanceId);
|
|
try
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
var snapshot = await driver.ReadAsync([tagName], ct);
|
|
await console.Output.WriteLineAsync(SnapshotFormatter.Format(Address, snapshot[0]));
|
|
}
|
|
finally
|
|
{
|
|
// Flush Serilog before process exit so buffered log output
|
|
// emitted during driver shutdown is not silently dropped (matching DriverCommandBase
|
|
// docs and every sibling CLI — Modbus / AbCip / AbLegacy / TwinCAT).
|
|
FlushLogging();
|
|
}
|
|
}
|
|
|
|
/// <summary>Constructs a tag name from address and data type.</summary>
|
|
/// <param name="address">The FOCAS address.</param>
|
|
/// <param name="type">The data type.</param>
|
|
/// <returns>The synthesised tag name in <c>address:type</c> form.</returns>
|
|
internal static string SynthesiseTagName(string address, FocasDataType type)
|
|