T
Joseph Doherty 9cad9ed0fc
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
2026-07-07 12:38:39 -04:00

64 lines
2.0 KiB
C#

using CliFx.Attributes;
using CliFx.Exceptions;
using CliFx.Infrastructure;
using Opc.Ua;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Helpers;
using ZB.MOM.WW.OtOpcUa.Client.Shared;
namespace ZB.MOM.WW.OtOpcUa.Client.CLI.Commands;
[Command("disable", Description = "Disable an alarm condition (OPC UA Part 9 ConditionType Disable)")]
public class DisableCommand : CommandBase
{
/// <summary>
/// Creates the disable command used to disable an OPC UA alarm condition from the terminal.
/// </summary>
/// <param name="factory">The factory that creates the shared client service for the command run.</param>
public DisableCommand(IOpcUaClientServiceFactory factory) : base(factory)
{
}
/// <summary>
/// Gets the condition node ID of the alarm to disable.
/// </summary>
[CommandOption("node", 'n', Description = "Condition node ID of the alarm to disable", IsRequired = true)]
public string NodeId { get; init; } = default!;
/// <inheritdoc />
public override async ValueTask ExecuteAsync(IConsole console)
{
ConfigureLogging();
try
{
NodeIdParser.ParseRequired(NodeId);
}
catch (Exception ex) when (ex is FormatException or ArgumentException)
{
throw new CommandException($"Invalid --node value: {ex.Message}");
}
IOpcUaClientService? service = null;
try
{
var ct = console.RegisterCancellationHandler();
(service, _) = await CreateServiceAndConnectAsync(ct);
var statusCode = await service.DisableAsync(NodeId, ct);
if (StatusCode.IsGood(statusCode))
await console.Output.WriteLineAsync($"Disable successful: {NodeId}");
else
await console.Output.WriteLineAsync($"Disable failed: {statusCode}");
}
finally
{
if (service != null)
{
await service.DisconnectAsync();
service.Dispose();
}
}
}
}