The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
86 lines
2.9 KiB
PowerShell
86 lines
2.9 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the AB CIP driver (ControlLogix / CompactLogix /
|
|
Micro800 / GuardLogix) bridged through the OtOpcUa server.
|
|
|
|
.DESCRIPTION
|
|
Mirrors test-modbus.ps1 but against libplctag's ab_server (or a real Logix
|
|
controller). Three assertions: probe / driver-loopback / server-bridge.
|
|
|
|
Prereqs:
|
|
- ab_server container up (tests/.../AbCip.IntegrationTests/Docker/docker-compose.yml,
|
|
--profile controllogix) OR a real PLC on the network.
|
|
- OtOpcUa server running with an AB CIP DriverInstance pointing at the
|
|
same gateway + a Tag published at the -BridgeNodeId you pass.
|
|
|
|
.PARAMETER Gateway
|
|
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0 (ab_server ControlLogix).
|
|
|
|
.PARAMETER Family
|
|
ControlLogix / CompactLogix / Micro800 / GuardLogix (default ControlLogix).
|
|
|
|
.PARAMETER TagPath
|
|
Logix symbolic path to exercise. Default 'TestDINT' — matches the ab_server
|
|
--tag=TestDINT:DINT[1] seed.
|
|
|
|
.PARAMETER OpcUaUrl
|
|
OtOpcUa server endpoint.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
NodeId at which the server publishes the TagPath.
|
|
#>
|
|
|
|
param(
|
|
[string]$Gateway = "ab://127.0.0.1/1,0",
|
|
[string]$Family = "ControlLogix",
|
|
[string]$TagPath = "TestDINT",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
$abcipCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbCip.Cli" `
|
|
-ExeName "otopcua-abcip-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonAbCip = @("-g", $Gateway, "-f", $Family)
|
|
$results = @()
|
|
|
|
# Probe via @raw_cpu_type for ControlLogix; against ab_server this surfaces the
|
|
# string 'Controllogix'. Other families use the main TestDINT.
|
|
$probeTag = if ($Family -eq "ControlLogix" -or $Family -eq "CompactLogix" -or $Family -eq "GuardLogix") {
|
|
"@raw_cpu_type"
|
|
} else {
|
|
$TagPath
|
|
}
|
|
$probeType = if ($probeTag -eq "@raw_cpu_type") { "String" } else { "DInt" }
|
|
|
|
$results += Test-Probe `
|
|
-Cli $abcipCli `
|
|
-ProbeArgs (@("probe") + $commonAbCip + @("-t", $probeTag, "--type", $probeType))
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $abcipCli `
|
|
-WriteArgs (@("write") + $commonAbCip + @("-t", $TagPath, "--type", "DInt", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonAbCip + @("-t", $TagPath, "--type", "DInt")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $abcipCli `
|
|
-DriverWriteArgs (@("write") + $commonAbCip + @("-t", $TagPath, "--type", "DInt", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
Write-Summary -Title "AB CIP e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|