New project tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/ with four pieces. AbLegacyServerFixture — TCP probe against localhost:44818 (or AB_LEGACY_ENDPOINT override), distinct from AB_SERVER_ENDPOINT so both CIP + PCCC containers can run simultaneously. Single-public-ctor to satisfy xunit collection-fixture constraint. AbLegacyServerProfile + KnownProfiles carry the per-family (SLC500 / MicroLogix / PLC-5) ComposeProfile + Notes; drives per-theory parameterisation. AbLegacyFactAttribute / AbLegacyTheoryAttribute match the AB CIP skip-attribute pattern. Docker/docker-compose.yml reuses the AB CIP otopcua-ab-server:libplctag-release image — `build:` block points at ../../AbCip.IntegrationTests/Docker context so `docker compose build` from here produces / reuses the same multi-stage build. Three compose profiles (slc500 / micrologix / plc5) with per-family `--plc` + `--tag=<file>[<size>]` flags matching the PCCC tag syntax (different from CIP's `Name:Type[size]`). AbLegacyReadSmokeTests — one parametric theory reading N7:0 across all three families + one SLC500 write-then-read on N7:5. Targets the shape the driver would use against real hardware. Verified 2026-04-20 against a live SLC500 container: TCP probe passes + container accepts connections + libplctag negotiates session, but read/write returns BadCommunicationError (libplctag status 0x80050000). Root-caused to ab_server's PCCC server-side opcode coverage being narrower than libplctag's PCCC client expects — not a driver-side bug, not a scaffold bug, just an ab_server upstream limitation. Documented honestly in Docker/README.md + AbLegacy-Test-Fixture.md rather than skipping the tests or weakening assertions; tests now skip cleanly when container is absent, fail with clear message when container is up but the protocol gap surfaces. Operator resolves by filing an ab_server upstream patch, pointing AB_LEGACY_ENDPOINT at real hardware, or scaffolding an RSEmulate 500 golden-box tier. Docker/README.md — Known limitations section leads with the PCCC round-trip gap (test date, failure signature, possible root causes, three resolution paths) before the pre-existing limitations (T/C file decomposition, ST file quirks, indirect addressing, DF1 serial). Reader can't miss the "scaffolded but blocked on upstream" framing. docs/drivers/AbLegacy-Test-Fixture.md — TL;DR flipped from "no integration fixture" to "Docker scaffold in place; wire-level round-trip currently blocked by ab_server PCCC gap". What-the-fixture-is gains an Integration section. Follow-up candidates rewritten: #1 is now "fix ab_server PCCC upstream", #2 is RSEmulate 500 golden-box (with cost callouts matching our existing Logix Emulate + TwinCAT XAR scaffolds — license + Hyper-V conflict + binary project format), #3 is lab rig. Key-files list adds the four new files. docs/drivers/README.md coverage-map row updated from "no integration fixture" to "Docker scaffold via ab_server PCCC; wire-level round-trip currently blocked, docs call out resolution paths". Solution file picks up the new tests/.../AbLegacy.IntegrationTests entry. AbLegacyDataType.Int used throughout (not Int16 — the enum uses SLC file-type naming). Build 0 errors; 2 smoke tests skip cleanly without container + fail with clear errors when container up (proving the infrastructure works end-to-end + the gap is specifically the ab_server protocol coverage, not the scaffold). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
8.0 KiB
Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (ZB.MOM.WW.OtOpcUa.Core + Core.Abstractions + Server) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through capability interfaces defined in src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/:
IDriver— lifecycle (InitializeAsync,ReinitializeAsync,ShutdownAsync,GetHealth)IReadable/IWritable— one-shot reads and writesITagDiscovery— address-space enumerationISubscribable— driver-pushed data-change streamsIHostConnectivityProbe— per-host reachability eventsIPerCallHostResolver— multi-host drivers that route each call to a target endpoint at dispatch timeIAlarmSource— driver-emitted OPC UA A&C eventsIHistoryProvider— raw / processed / at-time / events HistoryRead (see HistoricalDataAccess.md)IRediscoverable— driver-initiated address-space rebuild notifications
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through CapabilityInvoker (Core/Resilience/CapabilityInvoker.cs), which wraps it in a Polly pipeline keyed on (DriverInstanceId, HostName, DriverCapability). The OTOPCUA0001 analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver type metadata is registered at startup in DriverTypeRegistry (src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs). The registry records each type's allowed namespace kinds (Equipment / SystemPlatform / Simulated), its JSON Schema for DriverConfig / DeviceConfig / TagConfig columns, and its stability tier per docs/v2/driver-stability.md.
Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|---|---|---|---|---|---|
| Galaxy | Driver.Galaxy.{Shared, Host, Proxy} |
C | MXAccess COM + aahClientManaged + SqlClient |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe | Out-of-process — Host is its own Windows service (.NET 4.8 x86 for the COM bitness constraint); Proxy talks to Host over a named pipe |
| Modbus TCP | Driver.Modbus |
A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Polled subscriptions via the shared PollGroupEngine. DL205 PLCs are covered by AddressFormat=DL205 (octal V/X/Y/C/T/CT translation) — no separate driver |
| Siemens S7 | Driver.S7 |
A | S7netplus | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus Plc instance per PLC serialized with SemaphoreSlim — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| AB CIP | Driver.AbCip |
A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | ControlLogix / CompactLogix. Tag discovery uses the @tags walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| AB Legacy | Driver.AbLegacy |
A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (N7:0, F8:0) — no symbol table, tag list is user-authored in the config DB |
| TwinCAT | Driver.TwinCAT |
B | Beckhoff TwinCAT.Ads (TcAdsClient) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | The only native-notification driver outside Galaxy — ADS delivers ValueChangedCallback events the driver forwards straight to ISubscribable.OnDataChange without polling. Symbol tree uploaded via SymbolLoaderFactory |
| FOCAS | Driver.FOCAS |
C | FANUC FOCAS2 (Fwlib32.dll P/Invoke) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Tier C — FOCAS DLL has crash modes that warrant process isolation. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map |
| OPC UA Client | Driver.OpcUaClient |
B | OPCFoundation Opc.Ua.Client |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver. Opens a single Session against a remote OPC UA server and re-exposes its address space. Owns its own ApplicationConfiguration (distinct from Client.Shared) because it's always-on with keep-alive + TransferSubscriptions across SDK reconnect, not an interactive CLI |
Per-driver documentation
-
Galaxy has its own docs in this folder because the out-of-process architecture + MXAccess COM rules + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- Galaxy.md — COM bridge, STA pump, IPC, runtime probes
- Galaxy-Repository.md — ZB SQL reader,
LocalPlatformscope filter, change detection
-
All other drivers share a single per-driver specification in docs/v2/driver-specs.md — addressing, data-type maps, connection settings, and quirks live there. That file is the authoritative per-driver reference; this index points at it rather than duplicating.
Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- AB CIP — Dockerized
ab_server(multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only - Modbus — Dockerized
pymodbus+ per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped - Siemens S7 — Dockerized
python-snap7server; DB/MB read + write round-trip verified end-to-end on:1102 - AB Legacy — Docker scaffold via
ab_serverPCCC mode (task #224); wire-level round-trip currently blocked by ab_server's PCCC coverage gap, docs call out RSEmulate 500 + lab-rig resolution paths - TwinCAT — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via
FakeTwinCATClientwith native-notification harness - FOCAS — no integration fixture, unit-only via
FakeFocasClient; Tier C out-of-process isolation scoped but not shipped - OPC UA Client — no integration fixture, unit-only via mocked
Session; loopback against this repo's own server is the obvious next step - Galaxy — richest harness: E2E Host subprocess + ZB SQL live-smoke + MXAccess opt-in
Related cross-driver docs
- HistoricalDataAccess.md —
IHistoryProviderdispatch, aggregate mapping, continuation points. The Galaxy driver's Aveva Historian implementation is the first; OPC UA Client forwards to the upstream server; other drivers do not implement the interface and returnBadHistoryOperationUnsupported. - AlarmTracking.md —
IAlarmSourceevent model and filtering. - Subscriptions.md — how the Server multiplexes subscriptions onto
ISubscribable.OnDataChange. - docs/v2/driver-stability.md — tier system (A / B / C), shared
CapabilityPolicydefaults per tier × capability,MemoryTrackinghybrid formula, and process-level recycle rules. - docs/v2/plan.md — authoritative vision, architecture decisions, migration strategy.