#152 left a hook for structured logging when an auto-prohibition first fires; this commit completes the wiring. Changes: - ModbusDriver constructor takes an optional ILogger<ModbusDriver> (defaults to NullLogger). Existing standalone callers stay compile-clean. - RecordAutoProhibition logs LogWarning on first-fire only (re-fires of the same range stay quiet via the existing isNew de-dupe). Format includes DriverInstanceId, UnitId, Region, Start, End, Span — log aggregators can filter / count by any field. - New LogProhibitionCleared helper called by both StraightReprobeAsync (when the re-probe succeeds on a single-register range) and BisectAndReprobeAsync (per-half clearing + a single combined line when both halves succeed). - ModbusDriverFactoryExtensions.Register accepts an optional ILoggerFactory. Captured at registration time and used in the factory closure to construct a per-driver logger. Server bootstrap code that already has an ILoggerFactory in DI threads it through with a single argument addition; old call sites (Register(registry)) keep working with a null logger. Tests (2 new ModbusLoggerInjectionTests): - First_Failure_Emits_Single_Warning_Subsequent_Refire_Stays_Quiet — pins the de-dupe behaviour. First scan logs one warning with the expected structured fields; second scan with the same prohibition stays silent. - Reprobe_Clearing_Prohibition_Emits_Information_Log — protected register unlocked between record and re-probe; re-probe success emits an info log containing "cleared". CapturingLogger test harness is purpose-built (xUnit doesn't ship a logger mock by default and adding Moq is overkill for two tests). 240 + 2 = 242 unit tests green.