e08855fb9d
Adds deferment.md — a source-verified inventory of new-driver status, all 17
open issues, in-code deferrals, open live gates and plan bookkeeping. Every
claim was checked against src/ and git, not against documentation.
Headline finding: three subsystems are authored, persisted and shipped but
never executed —
* Node ACLs: IPermissionEvaluator/TriePermissionEvaluator have zero
production consumers and OtOpcUaNodeManager never references them, yet
ClusterAcls.razor authors NodeAcl rows and ConfigComposer.cs:51 ships them
in every artifact. An authored deny rule has no effect.
* IRediscoverable / IHostConnectivityProbe raise into the void (#518/#507);
nothing ever writes a DriverHostStatus row.
* DriverTypeRegistry is vestigial, so no factory passes a tier and every
driver runs Tier A with the Tier-C protections dormant.
Also records the Calculation driver as picker-visible but unauthorable
(DriverConfigModal has no case) — the "registered but unauthorable" class
recurring after the Sql picker defect — and notes that no parity test guards
DriverConfigModal/DeviceModal, which is why it survived review.
Documentation corrections (source-verified):
* ReadWriteOperations.md claimed "a denied read never hits the driver" via
four types that do not exist in src/. Bannered + struck through; a security
review reading that page would have concluded a per-node ACL gate exists.
* CLAUDE.md: the Change Detection sentence was false (DriverHost consumes
nothing); the mesh Phase 4 and Phase 5 live gates and the auto-down 1-vs-1
gate had all PASSED; the ScriptedAlarmState table was already dropped.
* driver-expansion tracking: Modbus RTU and SQL poll are merged, not
pending — its command table would have made someone rebuild two shipped
drivers in a fresh worktree.
* drivers/README.md: dead DriverTypeRegistry paragraph, retired
SystemPlatform namespace kind, missing Sql + Calculation rows, missing
Modbus RTU-over-TCP transport.
* TwinCAT.md/Galaxy.md promised an address-space rebuild that never happens.
* Historian.md gained the #491 unproven-value-capture pointer.
* IncrementalSync.md and AddressSpace.md bannered as wholesale v2-era (the
rewrite is recorded as still owed, not done here); four v2 status docs
bannered as historical; three wrong-name-for-a-live-type fixes.
Left deliberately untouched: the secrets NoOpSecretReplicator line, which
makes a security claim and needs the real behaviour identified rather than a
rename.
91 lines
18 KiB
Markdown
91 lines
18 KiB
Markdown
# Drivers
|
||
|
||
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and the two v3 OPC UA namespaces (Raw + UNS — see `V3NodeIds` / `AddressSpaceRealm`). Drivers plug in through **capability interfaces** defined in `src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
|
||
|
||
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
|
||
- `IReadable` / `IWritable` — one-shot reads and writes
|
||
- `ITagDiscovery` — address-space enumeration
|
||
- `ISubscribable` — driver-pushed data-change streams
|
||
- `IHostConnectivityProbe` — per-host reachability events
|
||
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
|
||
- `IAlarmSource` — driver-emitted OPC UA A&C events
|
||
- `IHistoryProvider` — driver-side raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md))
|
||
- `IRediscoverable` — driver-initiated address-space rebuild notifications
|
||
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-side `IHistoryProvider` HistoryRead path
|
||
|
||
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
|
||
|
||
Driver **factories** are registered at startup in `DriverFactoryRegistry` (`src/Core/ZB.MOM.WW.OtOpcUa.Core/Hosting/DriverFactoryRegistry.cs`) — all 12 in one place, `src/Server/ZB.MOM.WW.OtOpcUa.Host/Drivers/DriverFactoryBootstrap.cs:147-164`. Type names are the `DriverTypeNames` constants (`src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeNames.cs`), guarded bidirectionally by `DriverTypeNamesGuardTests`.
|
||
|
||
> ⚠️ **`DriverTypeRegistry` / `DriverTypeMetadata` are vestigial.** No production code constructs or reads them — the class is referenced only by its own unit tests. Its `AllowedNamespaceKinds` field was retired along with the v3 `Namespace` entity (`DriverTypeRegistry.cs:97`), and the `SystemPlatform` namespace kind no longer exists.
|
||
>
|
||
> **Stability tier** likewise does not come from that registry: it is the `DriverTier tier = DriverTier.A` parameter on `DriverFactoryRegistry.cs:46`, and **no factory in `src/Drivers/` passes a tier**, so every shipped driver runs Tier A. The Tier-C-only protections described in [docs/v2/driver-stability.md](../v2/driver-stability.md) — `MemoryRecycle` hard-breach kill (`MemoryRecycle.cs:54`) and `ScheduledRecycleScheduler` (`:43`) — are therefore dormant for every driver.
|
||
|
||
## Ground-truth driver list
|
||
|
||
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|
||
|--------|--------------|:----:|----------------|--------------|---------------|
|
||
| [Galaxy](Galaxy.md) | `Driver.Galaxy` (+ `.Browser`, `.Contracts`) | A | gRPC to the external `mxaccessgw` gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process `Galaxy.{Shared, Host, Proxy}` + named-pipe Windows service. Native MxAccess alarms work end-to-end |
|
||
| [Modbus TCP / RTU-over-TCP](Modbus.md) | `Driver.Modbus` (+ `.Addressing`, `.Contracts`) | A | NModbus-derived in-house client; `Transport` selects MBAP (TCP) or RTU CRC-16 framing over a socket | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver. `Transport=RtuOverTcp` (`ModbusTransportMode`, default `Tcp`) targets serial→Ethernet gateways via `ModbusRtuOverTcpTransport` + `ModbusRtuFraming` + `ModbusCrc`, with `ModbusTransportDesyncException` carrying distinct CrcMismatch/UnitMismatch reasons; **direct-serial transport is descoped**. Merged `0f38f486` (#495) |
|
||
| [Siemens S7](S7.md) | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
|
||
| [AB CIP](AbCip.md) | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
|
||
| [AB Legacy](AbLegacy.md) | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
|
||
| [TwinCAT](TwinCAT.md) | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
|
||
| [FOCAS](FOCAS.md) | `Driver.FOCAS` | A | Pure-managed `FocasWireClient` — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | `IWritable` is implemented but read-only by design — `WriteAsync` returns `BadNotWritable` for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
|
||
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side `IHistoryProvider` (forwards HistoryRead to the upstream server). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
|
||
| [MQTT](Mqtt.md) | `Driver.Mqtt` (+ `.Browser`, `.Contracts`) | A | [MQTTnet 5](https://github.com/dotnet/MQTTnet) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | **Push, not poll, and read-only** — the broker delivers PUBLISH frames the driver forwards straight to `ISubscribable.OnDataChange`; `IReadable` serves the last retained/received value from cache, and there is **no `IWritable`** (nothing publishes back). Subscriptions are indexed **by topic filter, not by topic**, so wildcard tags survive a reconnect. A rejected CONNACK throws `MqttConnectRejectedException`: unrecoverable codes → `Faulted` + supervisor stop, transient → retry. **Two modes:** `Plain` binds a tag to a concrete topic + JSON path; `SparkplugB` decodes vendored Eclipse-Tahu protobuf under one `spBv1.0/{groupId}/#` subscription and binds by the `group/edgeNode/device?/metric` tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). `IRediscoverable` fires on a DBIRTH but is **inert platform-side** — see [#507](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/507) |
|
||
| [MTConnect](MTConnect.md) | `Driver.MTConnect` (+ `.Contracts`) | — | Hand-rolled `System.Xml.Linq` HTTP/XML client against a vendor-neutral MTConnect Agent (`/probe`, `/current`, `/sample`) — no TrakHound dependency (dropped; see the driver doc) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Read-only by design (no `IWritable`). Production data plane is entirely `ISubscribable`/`OnDataChange` — `IReadable` is CLI/test-only. Browse is free via the Wave-0 universal discovery browser, no bespoke browser project. `IRediscoverable`/`IHostConnectivityProbe` have no server-side consumer yet — a pre-existing fleet-wide gap, not MTConnect-specific |
|
||
| **Sql** (no dedicated page — see [design](../plans/2026-07-15-sql-poll-driver-design.md)) | `Driver.Sql` (+ `.Browser`, `.Contracts`) | A | `Microsoft.Data.SqlClient` behind an `ISqlDialect` seam (`SqlServerDialect` shipped; Postgres/ODBC deferred) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe | Read-only DB-poll driver with a bespoke schema browser. **Credentials are never persisted** — the deploy gate rejects a stored `connectionString` (#498) and catalog identifiers are validated against the live catalog's own spelling (#496). `SupportsOnlineDiscovery => false` by design (the bespoke browser wins). `SqlTagModel.Query` is deferred to P3 and rejected end-to-end by parser, validator, planner and editor. Merged `4ad54037` |
|
||
| **Calculation** (see [Raw.md](../Raw.md#the-calculation-driver)) | `Driver.Calculation` | A | none — computes from other tags' RawPaths | IDriver, IDependencyConsumer, ISubscribable, IReadable | **Pseudo-driver**, not a wire protocol: signal-level tags computed from other tags via a script, with deploy-time `scriptId`-existence + Tarjan cycle gates. Its probe is parse-only (no backend to reach). ⚠️ **No typed config form** — `DriverConfigModal` has no `Calculation` case, so `RunTimeout` is currently unauthorable through the AdminUI |
|
||
| [Historian.Gateway](../Historian.md) | `Driver.Historian.Gateway` | — | `ZB.MOM.WW.HistorianGateway.Client` gRPC (`historian_gateway.v1`) | IHistorianDataSource (server-side read backend) + alarm `SendEvent` writer + `WriteLiveValues` recorder + `IHistorianProvisioning` | Not a tag driver — the sole historian backend. Registers `GatewayHistorianDataSource : IHistorianDataSource` for HistoryRead and serves alarm-write + continuous historization through the gateway. No `IDriver`/`ITagDiscovery` surface. (The retired Wonderware sidecar backend it replaced is documented at [Historian.Wonderware.md](Historian.Wonderware.md).) |
|
||
|
||
## Per-driver documentation
|
||
|
||
- **Galaxy** has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
|
||
- [Galaxy.md](Galaxy.md) — gateway gRPC bridge, hierarchy source, runtime probes
|
||
- [Galaxy-Repository.md](../v1/drivers/Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection (v1 archive)
|
||
|
||
- **FOCAS** has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
|
||
- [FOCAS.md](FOCAS.md) — deployment, config, capability surface, alarm projection, troubleshooting
|
||
|
||
- **Modbus TCP**, **AB CIP**, **AB Legacy**, **Siemens S7**, **TwinCAT**, **OPC UA Client**, and **MQTT** each have a per-driver overview page:
|
||
- [Modbus.md](Modbus.md) — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
|
||
- [AbCip.md](AbCip.md) — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
|
||
- [AbLegacy.md](AbLegacy.md) — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
|
||
- [S7.md](S7.md) — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
|
||
- [TwinCAT.md](TwinCAT.md) — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
|
||
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
|
||
- [Mqtt.md](Mqtt.md) — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding, `#`-observation browser, CONNACK-rejection semantics, **Sparkplug B** (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the **Known gaps** table
|
||
|
||
- **MTConnect** has a short getting-started doc because the hand-rolled-vs-TrakHound divergence, the
|
||
data-plane precedence rules, and a non-trivial known-limitations list need explaining up front:
|
||
- [MTConnect.md](MTConnect.md) — Agent config, `FullName`==DataItem `id`, `UNAVAILABLE`→`BadNoCommunication`, CONDITION-as-`String`, browse-via-universal-browser, fixture recipe, deferred write-back
|
||
|
||
- **Historian.Gateway** (server-side historian backend, not a tag driver) is documented in the main guide:
|
||
- [../Historian.md](../Historian.md) — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (`SendEvent`), continuous historization (`WriteLiveValues`), `EnsureTags` provisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: [Historian.Wonderware.md](Historian.Wonderware.md).)
|
||
|
||
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path; that file is the authoritative per-driver reference.
|
||
|
||
## Test-fixture coverage maps
|
||
|
||
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
|
||
|
||
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
|
||
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
|
||
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
|
||
- [AB Legacy](AbLegacy-Test-Fixture.md) — Dockerized `ab_server` PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. `/1,0` cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (`B3:0/5`) still surface BadState — real HW / RSEmulate 500 for those
|
||
- [TwinCAT](TwinCAT-Test-Fixture.md) — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via `FakeTwinCATClient` with native-notification harness
|
||
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
|
||
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — Dockerized `opc-plc` integration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mocked `Session`
|
||
- [MQTT](Mqtt-Test-Fixture.md) — Dockerized `eclipse-mosquitto` with **TLS + real auth on both listeners (no anonymous fallback)** + a JSON-publisher sidecar; env-gated live suite (**15 tests**) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a **project-owned C# edge-node simulator** on the `sparkplug` compose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, so `docker restart otopcua-sparkplug-sim` is how you force a fresh one
|
||
- [Galaxy](../v1/drivers/Galaxy-Test-Fixture.md) — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
|
||
- [MTConnect](../../tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.MTConnect.IntegrationTests/Docker/README.md) — Dockerized `mtconnect/agent` + stdlib SHDR adapter (two services, the Agent alone reports everything `UNAVAILABLE`); 12/12 against the real Agent, canned XML unit fixtures cover the bulk (491/491)
|
||
|
||
## Related cross-driver docs
|
||
|
||
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
|
||
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
|
||
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
|
||
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
|
||
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.
|