Files
lmxopcua/docs/drivers/README.md
T
Joseph Doherty cbb882293b refactor(drivers): delete the inert driver-tier recycle machinery (#522)
The tier system was documented, operator-authorable, and inert. Deleted rather than activated,
because its premise is gone rather than merely unused.

"Tier C" meant a driver running out-of-process behind an IDriverSupervisor that could restart its
Host without tearing down the OPC UA session. No such process exists anywhere: Galaxy reaches
MXAccess over gRPC to the external mxaccessgw sidecar (PR 7.2 retired the in-process
Galaxy.Host/Proxy/Shared projects) and FOCAS has run in-process since its managed wire client
landed 2026-04-24. Consistently, IDriverSupervisor had ZERO implementations and there was nothing
for one to implement against.

The issue understated the inertness. It says the Tier-C-only protections never engaged, implying
the Tier A/B parts did. They did not: nothing constructs MemoryTracking, MemoryRecycle or
ScheduledRecycleScheduler outside their own unit tests, so the whole Core/Stability recycle layer
was dead — meaning option (a), "pass real tiers", was never a flag flip. It would have meant
writing the wiring that never existed AND arming it.

Deleted: MemoryTracking, MemoryRecycle, ScheduledRecycleScheduler, IDriverSupervisor, the
vestigial DriverTypeRegistry (referenced only by its own tests), and the RecycleIntervalSeconds
knob — which the AdminUI let an operator author and the parser validated while it configured
nothing.

DriverTier itself SURVIVES and is load-bearing: DriverResilienceOptions.GetTierDefaults supplies
the real per-capability timeout/retry/breaker policies via DriverFactoryRegistry.GetTier and
DriverCapabilityInvokerFactory. Only the isolation-and-recycle layer above it is gone.

Deliberately NOT deleted:

- WedgeDetector came along in the same directory and is equally dead in production, but it is
  tier-agnostic and is not recycle machinery — it only shares the folder. Restored rather than
  swept up in a decision that was not about it.
- IDriver.GetMemoryFootprint() and FlushOptionalCachesAsync() lose their only consumer here.
  Removing them touches all 12 drivers and every test stub, so they are documented as
  consumerless and filed as #525 instead of buried in this diff.

Compatibility: a deployed ResilienceConfig blob still carrying "recycleIntervalSeconds" parses
cleanly (unknown keys are ignored — guarded by a new test, because a blob that suddenly failed to
parse would fall back to tier defaults and silently discard the operator's real overrides), and
the AdminUI's preserve-unknown-keys bag keeps the key rather than rewriting stored config on an
unrelated edit.

The 01/U-6 knob-inertness guard carried an explicit carve-out admitting RecycleIntervalSeconds was
dormant and out of scope; that carve-out is now gone, so the expected set is literally what the
test's name claims.

Note: Host.IntegrationTests has 2 failures (DriverProbeRegistrationTests.is_idempotent,
PrimaryGateFailoverTests) — verified pre-existing by reproducing both on clean master dc9d947b.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-30 04:44:04 -04:00

91 lines
18 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and the two v3 OPC UA namespaces (Raw + UNS — see `V3NodeIds` / `AddressSpaceRealm`). Drivers plug in through **capability interfaces** defined in `src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
- `IReadable` / `IWritable` — one-shot reads and writes
- `ITagDiscovery` — address-space enumeration
- `ISubscribable` — driver-pushed data-change streams
- `IHostConnectivityProbe` — per-host reachability events
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
- `IAlarmSource` — driver-emitted OPC UA A&C events
- `IHistoryProvider` — driver-side raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md))
- `IRediscoverable` — driver-initiated address-space rebuild notifications
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-side `IHistoryProvider` HistoryRead path
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver **factories** are registered at startup in `DriverFactoryRegistry` (`src/Core/ZB.MOM.WW.OtOpcUa.Core/Hosting/DriverFactoryRegistry.cs`) — all 12 in one place, `src/Server/ZB.MOM.WW.OtOpcUa.Host/Drivers/DriverFactoryBootstrap.cs:147-164`. Type names are the `DriverTypeNames` constants (`src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeNames.cs`), guarded bidirectionally by `DriverTypeNamesGuardTests`.
> ⚠️ **`DriverTypeRegistry` / `DriverTypeMetadata` were DELETED (Gitea #522, 2026-07-30).** They were vestigial — no production code constructed or read them, only their own unit tests did — and `AllowedNamespaceKinds` had already been orphaned by the retirement of the v3 `Namespace` entity. Older docs and plans that name them as the driver-metadata or tier authority describe something that no longer exists.
>
> **Stability tier** never came from that registry anyway: it is the `DriverTier tier = DriverTier.A` parameter on `DriverFactoryRegistry.cs:46`, and **no factory in `src/Drivers/` passes a tier**, so every shipped driver runs Tier A. The Tier-C recycle protections that [docs/v2/driver-stability.md](../v2/driver-stability.md) describes — `MemoryTracking`, `MemoryRecycle`, `ScheduledRecycleScheduler`, `IDriverSupervisor` — are **gone**, not merely dormant: they required an out-of-process driver Host that no longer exists anywhere (Galaxy is gRPC-to-`mxaccessgw`, FOCAS is in-process), `IDriverSupervisor` had no implementations, and the trackers were only ever constructed in tests. The `Tier` column below is therefore uniformly A, and the tier's remaining effect is `DriverResilienceOptions.GetTierDefaults` — the per-capability timeout / retry / breaker policy set, which **is** live.
## Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|--------|--------------|:----:|----------------|--------------|---------------|
| [Galaxy](Galaxy.md) | `Driver.Galaxy` (+ `.Browser`, `.Contracts`) | A | gRPC to the external `mxaccessgw` gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process `Galaxy.{Shared, Host, Proxy}` + named-pipe Windows service. Native MxAccess alarms work end-to-end |
| [Modbus TCP / RTU-over-TCP](Modbus.md) | `Driver.Modbus` (+ `.Addressing`, `.Contracts`) | A | NModbus-derived in-house client; `Transport` selects MBAP (TCP) or RTU CRC-16 framing over a socket | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver. `Transport=RtuOverTcp` (`ModbusTransportMode`, default `Tcp`) targets serial→Ethernet gateways via `ModbusRtuOverTcpTransport` + `ModbusRtuFraming` + `ModbusCrc`, with `ModbusTransportDesyncException` carrying distinct CrcMismatch/UnitMismatch reasons; **direct-serial transport is descoped**. Merged `0f38f486` (#495) |
| [Siemens S7](S7.md) | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| [AB CIP](AbCip.md) | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| [AB Legacy](AbLegacy.md) | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
| [TwinCAT](TwinCAT.md) | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
| [FOCAS](FOCAS.md) | `Driver.FOCAS` | A | Pure-managed `FocasWireClient` — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | `IWritable` is implemented but read-only by design — `WriteAsync` returns `BadNotWritable` for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side `IHistoryProvider` (forwards HistoryRead to the upstream server). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
| [MQTT](Mqtt.md) | `Driver.Mqtt` (+ `.Browser`, `.Contracts`) | A | [MQTTnet 5](https://github.com/dotnet/MQTTnet) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | **Push, not poll, and read-only** — the broker delivers PUBLISH frames the driver forwards straight to `ISubscribable.OnDataChange`; `IReadable` serves the last retained/received value from cache, and there is **no `IWritable`** (nothing publishes back). Subscriptions are indexed **by topic filter, not by topic**, so wildcard tags survive a reconnect. A rejected CONNACK throws `MqttConnectRejectedException`: unrecoverable codes → `Faulted` + supervisor stop, transient → retry. **Two modes:** `Plain` binds a tag to a concrete topic + JSON path; `SparkplugB` decodes vendored Eclipse-Tahu protobuf under one `spBv1.0/{groupId}/#` subscription and binds by the `group/edgeNode/device?/metric` tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). `IRediscoverable` fires on a DBIRTH but is **inert platform-side** — see [#507](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/507) |
| [MTConnect](MTConnect.md) | `Driver.MTConnect` (+ `.Contracts`) | — | Hand-rolled `System.Xml.Linq` HTTP/XML client against a vendor-neutral MTConnect Agent (`/probe`, `/current`, `/sample`) — no TrakHound dependency (dropped; see the driver doc) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Read-only by design (no `IWritable`). Production data plane is entirely `ISubscribable`/`OnDataChange``IReadable` is CLI/test-only. Browse is free via the Wave-0 universal discovery browser, no bespoke browser project. `IRediscoverable`/`IHostConnectivityProbe` have no server-side consumer yet — a pre-existing fleet-wide gap, not MTConnect-specific |
| [Sql](Sql.md) | `Driver.Sql` (+ `.Browser`, `.Contracts`) | A | `Microsoft.Data.SqlClient` behind an `ISqlDialect` seam (`SqlServerDialect` shipped; Postgres/ODBC deferred) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe | Read-only DB-poll driver with a bespoke schema browser. **Credentials are never persisted** — the deploy gate rejects a stored `connectionString` (#498) and catalog identifiers are validated against the live catalog's own spelling (#496). `SupportsOnlineDiscovery => false` by design (the bespoke browser wins). `SqlTagModel.Query` is deferred to P3 and rejected end-to-end by parser, validator, planner and editor. Merged `4ad54037` |
| [Calculation](Calculation.md) | `Driver.Calculation` | A | none — computes from other tags' RawPaths | IDriver, IDependencyConsumer, ISubscribable, IReadable | **Pseudo-driver**, not a wire protocol: signal-level tags computed from other tags via a script, with deploy-time `scriptId`-existence + Tarjan cycle gates. Its probe is parse-only (no backend to reach). `runTimeoutMs` is authorable through `CalculationDriverForm` (the "no typed config form" gap — G-1 — was closed 2026-07-27) |
| [Historian.Gateway](../Historian.md) | `Driver.Historian.Gateway` | — | `ZB.MOM.WW.HistorianGateway.Client` gRPC (`historian_gateway.v1`) | IHistorianDataSource (server-side read backend) + alarm `SendEvent` writer + `WriteLiveValues` recorder + `IHistorianProvisioning` | Not a tag driver — the sole historian backend. Registers `GatewayHistorianDataSource : IHistorianDataSource` for HistoryRead and serves alarm-write + continuous historization through the gateway. No `IDriver`/`ITagDiscovery` surface. (The retired Wonderware sidecar backend it replaced is documented at [Historian.Wonderware.md](Historian.Wonderware.md).) |
## Per-driver documentation
- **Galaxy** has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- [Galaxy.md](Galaxy.md) — gateway gRPC bridge, hierarchy source, runtime probes
- [Galaxy-Repository.md](../v1/drivers/Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection (v1 archive)
- **FOCAS** has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
- [FOCAS.md](FOCAS.md) — deployment, config, capability surface, alarm projection, troubleshooting
- **Modbus TCP**, **AB CIP**, **AB Legacy**, **Siemens S7**, **TwinCAT**, **OPC UA Client**, and **MQTT** each have a per-driver overview page:
- [Modbus.md](Modbus.md) — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
- [AbCip.md](AbCip.md) — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
- [AbLegacy.md](AbLegacy.md) — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
- [S7.md](S7.md) — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
- [TwinCAT.md](TwinCAT.md) — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
- [Mqtt.md](Mqtt.md) — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding, `#`-observation browser, CONNACK-rejection semantics, **Sparkplug B** (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the **Known gaps** table
- **MTConnect** has a short getting-started doc because the hand-rolled-vs-TrakHound divergence, the
data-plane precedence rules, and a non-trivial known-limitations list need explaining up front:
- [MTConnect.md](MTConnect.md) — Agent config, `FullName`==DataItem `id`, `UNAVAILABLE``BadNoCommunication`, CONDITION-as-`String`, browse-via-universal-browser, fixture recipe, deferred write-back
- **Historian.Gateway** (server-side historian backend, not a tag driver) is documented in the main guide:
- [../Historian.md](../Historian.md) — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (`SendEvent`), continuous historization (`WriteLiveValues`), `EnsureTags` provisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: [Historian.Wonderware.md](Historian.Wonderware.md).)
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path; that file is the authoritative per-driver reference.
## Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
- [AB Legacy](AbLegacy-Test-Fixture.md) — Dockerized `ab_server` PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. `/1,0` cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (`B3:0/5`) still surface BadState — real HW / RSEmulate 500 for those
- [TwinCAT](TwinCAT-Test-Fixture.md) — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via `FakeTwinCATClient` with native-notification harness
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — Dockerized `opc-plc` integration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mocked `Session`
- [MQTT](Mqtt-Test-Fixture.md) — Dockerized `eclipse-mosquitto` with **TLS + real auth on both listeners (no anonymous fallback)** + a JSON-publisher sidecar; env-gated live suite (**15 tests**) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a **project-owned C# edge-node simulator** on the `sparkplug` compose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, so `docker restart otopcua-sparkplug-sim` is how you force a fresh one
- [Galaxy](../v1/drivers/Galaxy-Test-Fixture.md) — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
- [MTConnect](../../tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.MTConnect.IntegrationTests/Docker/README.md) — Dockerized `mtconnect/agent` + stdlib SHDR adapter (two services, the Agent alone reports everything `UNAVAILABLE`); 12/12 against the real Agent, canned XML unit fixtures cover the bulk (491/491)
## Related cross-driver docs
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.