Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Server.Tests/NodeScopeResolverTests.cs
Joseph Doherty 1bf3938cdf ADR-001 Task B — NodeScopeResolver full-path + ScopePathIndexBuilder + evaluator-level ACL test closing #195. Two production additions + one end-to-end authz regression test proving the Identification ACL contract the IdentificationFolderBuilder docstring promises. Task A (PR #153) shipped the walker as a pure function that materializes the UNS → Equipment → Tag browse tree + IdentificationFolderBuilder.Build per Equipment. This PR lands the authz half of the walker's story — the resolver side that turns a driver-side full reference into a full NodeScope path (NamespaceId + UnsAreaId + UnsLineId + EquipmentId + TagId) so the permission trie can walk the UNS hierarchy + apply Equipment-scope grants correctly at dispatch time. The actual in-server wiring (load snapshot → call walker during BuildAddressSpaceAsync → swap in the full-path resolver) is split into follow-up task #212 because it's a bigger surface (Server bootstrap + DriverNodeManager override + real OPC UA client-browse integration test). NodeScopeResolver extended with a second constructor taking IReadOnlyDictionary<string, NodeScope> pathIndex — when supplied, Resolve looks up the full reference in the index + returns the indexed scope with every UNS level populated; when absent or on miss, falls back to the pre-ADR-001 cluster-only scope so driver-discovered tags that haven't been indexed yet (between a DiscoverAsync result + the next generation publish) stay addressable without crashing the resolver. Index is frozen into a FrozenDictionary<string, NodeScope> under Ordinal comparer for O(1) hot-path lookups. Thread-safety by immutability — callers swap atomically on generation change via the server's publish pipeline. New ScopePathIndexBuilder.Build in Server.Security takes (clusterId, namespaceId, EquipmentNamespaceContent) + produces the fullReference → NodeScope dictionary by joining Tag → Equipment → UnsLine → UnsArea through up-front dictionaries keyed Ordinal-ignoring-case. Tag rows with null EquipmentId (SystemPlatform-namespace Galaxy tags per decision #120) are excluded from the index; cluster-only fallback path covers them. Broken FKs (Tag references missing Equipment row, or Equipment references missing UnsLine) are skipped rather than crashing — sp_ValidateDraft should have caught these at publish, any drift here is unexpected but non-fatal. Duplicate keys throw InvalidOperationException at bootstrap so corrupt-data drift surfaces up-front instead of producing silently-last-wins scopes at dispatch. End-to-end authz regression test in EquipmentIdentificationAuthzTests walks the full dispatch flow against a Config-DB-style fixture: ScopePathIndexBuilder.Build from the same EquipmentNamespaceContent the EquipmentNodeWalker consumes → NodeScopeResolver with that index → AuthorizationGate + TriePermissionEvaluator → PermissionTrieBuilder with one Equipment-scope NodeAcl grant + a NodeAclPath resolving Equipment ScopeId to (namespace, area, line, equipment). Four tests prove the contract: (a) authorized group Read granted on Identification property; (b) unauthorized group Read denied on Identification property — the #195 contract the IdentificationFolderBuilder docstring promises (the BadUserAccessDenied surfacing happens at the DriverNodeManager dispatch layer which is already wired to AuthorizationGate.IsAllowed → StatusCodes.BadUserAccessDenied in PR #94); (c) Equipment-scope grant cascades to both the Equipment's tag + its Identification properties because they share the Equipment ScopeId — no new scope level for Identification per the builder's Remarks section; (d) grant on oven-3 does NOT leak to press-7 (different equipment under the same UnsLine) proving per-Equipment isolation at dispatch when the resolver populates the full path. NodeScopeResolverTests extended with two new tests covering the indexed-lookup path + fallback-on-miss path; renamed the existing "_For_Phase1" test to "_When_NoIndexSupplied" to match the current framing. Server project builds 0 errors; Server.Tests 179/179 (was 173, +6 new across the two test files). Task #212 captures the remaining in-server wiring work — Server.SealedBootstrap load of EquipmentNamespaceContent, DriverNodeManager override that calls EquipmentNodeWalker during BuildAddressSpaceAsync for Equipment-kind namespaces, and a real OPC UA client-browse integration test. With that wiring + this PR's authz-layer proof, #195's "ACL integration test" line is satisfied at two layers (evaluator + live endpoint) which is stronger than the task originally asked for.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 02:50:27 -04:00

3.2 KiB