Files
lmxopcua/docs/drivers/README.md
Joseph Doherty 1d3544f18e S7 integration fixture — python-snap7 server closes the wire-level coverage gap (#216) + per-driver fixture coverage docs for every driver in the fleet. Closes #216. Two shipments in one PR because the docs landed as I surveyed each driver's fixture + the S7 work is the first wire-level-gap closer pulled from that survey.
S7 integration — AbCip/Modbus already have real-simulator integration suites; S7 had zero wire-level coverage despite being a Tier-A driver (all unit tests mocked IS7Client). Picked python-snap7's `snap7.server.Server` over raw Snap7 C library because `pip install` beats per-OS binary-pin maintenance, the package ships a Python __main__ shim that mirrors our existing pymodbus serve.ps1 + *.json pattern structurally, and the python-snap7 project is actively maintained. New project `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/` with four moving parts: (a) `Snap7ServerFixture` — collection-scoped TCP probe on `localhost:1102` that sets `SkipReason` when the simulator's not running, matching the `ModbusSimulatorFixture` shape one directory over (same S7_SIM_ENDPOINT env var override convention for pointing at a real S7 CPU on port 102); (b) `PythonSnap7/` — `serve.ps1` wrapper + `server.py` shim + `s7_1500.json` seed profile + `README.md` documenting install / run / known limitations; (c) `S7_1500/S7_1500Profile.cs` — driver-side `S7DriverOptions` whose tag addresses map 1:1 to the JSON profile's seed offsets (DB1.DBW0 u16, DB1.DBW10 i16, DB1.DBD20 i32, DB1.DBD30 f32, DB1.DBX50.3 bool, DB1.DBW100 scratch); (d) `S7_1500SmokeTests` — three tests proving typed reads + write-then-read round-trip work through real S7netplus + real ISO-on-TCP + real snap7 server. Picked port 1102 default instead of S7-standard 102 because 102 is privileged on Linux + triggers Windows Firewall prompt; S7netplus 0.20 has a 5-arg `Plc(CpuType, host, port, rack, slot)` ctor that lets the driver honour `S7DriverOptions.Port`, but the existing driver code called the 4-arg overload + silently hardcoded 102. One-line driver fix (S7Driver.cs:87) threads `_options.Port` through — the S7 unit suite (58/58) still passes unchanged because every unit test uses a fake IS7Client that never sees the real ctor. Server seed-type matrix in `server.py` covers u8 / i8 / u16 / i16 / u32 / i32 / f32 / bool-with-bit / ascii (S7 STRING with max_len header). register_area takes the SrvArea enum value, not the string name — a 15-minute debug after the first test run caught that; documented inline.

Per-driver test-fixture coverage docs — eight new files in `docs/drivers/` laying out what each driver's harness actually benchmarks vs. what's trusted from field deployments. Pattern mirrors the AbServer-Test-Fixture.md doc that shipped earlier in this arc: TL;DR → What the fixture is → What it actually covers → What it does NOT cover → When-to-trust table → Follow-up candidates → Key files. Ugly truth the survey made visible: Galaxy + Modbus + (now) S7 + AB CIP have real wire-level coverage; AB Legacy / TwinCAT / FOCAS / OpcUaClient are still contract-only because their libraries ship no fake + no open-source simulator exists (AB Legacy PCCC), no public simulator exists (FOCAS), the vendor SDK has no in-process fake (TwinCAT/ADS.NET), or the test wiring just hasn't happened yet (OpcUaClient could trivially loopback against this repo's own server — flagged as #215). Each doc names the specific follow-up route: Snap7 server for S7 (done), TwinCAT 3 developer-runtime auto-restart for TwinCAT, Tier-C out-of-process Host for FOCAS, lab rigs for AB Legacy + hardware-gated bits of the others. `docs/drivers/README.md` gains a coverage-map section linking all eight. Tracking tasks #215-#222 filed for each PR-able follow-up.

Build clean (driver + integration project + docs); S7.Tests 58/58 (unchanged); S7.IntegrationTests 3/3 (new, verified end-to-end against a live python-snap7 server: `driver_reads_seeded_u16_through_real_S7comm`, `driver_reads_seeded_typed_batch`, `driver_write_then_read_round_trip_on_scratch_word`). Next fixture follow-up is #215 (OpcUaClient loopback against own server) — highest ROI of the remaining set, zero external deps.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 11:29:15 -04:00

60 lines
7.7 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through **capability interfaces** defined in `src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
- `IReadable` / `IWritable` — one-shot reads and writes
- `ITagDiscovery` — address-space enumeration
- `ISubscribable` — driver-pushed data-change streams
- `IHostConnectivityProbe` — per-host reachability events
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
- `IAlarmSource` — driver-emitted OPC UA A&C events
- `IHistoryProvider` — raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../HistoricalDataAccess.md))
- `IRediscoverable` — driver-initiated address-space rebuild notifications
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver type metadata is registered at startup in `DriverTypeRegistry` (`src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs`). The registry records each type's allowed namespace kinds (`Equipment` / `SystemPlatform` / `Simulated`), its JSON Schema for `DriverConfig` / `DeviceConfig` / `TagConfig` columns, and its stability tier per [docs/v2/driver-stability.md](../v2/driver-stability.md).
## Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|--------|--------------|:----:|----------------|--------------|---------------|
| [Galaxy](Galaxy.md) | `Driver.Galaxy.{Shared, Host, Proxy}` | C | MXAccess COM + `aahClientManaged` + SqlClient | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe | Out-of-process — Host is its own Windows service (.NET 4.8 x86 for the COM bitness constraint); Proxy talks to Host over a named pipe |
| Modbus TCP | `Driver.Modbus` | A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver |
| Siemens S7 | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| AB CIP | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| AB Legacy | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
| TwinCAT | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
| FOCAS | `Driver.FOCAS` | C | FANUC FOCAS2 (`Fwlib32.dll` P/Invoke) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Tier C — FOCAS DLL has crash modes that warrant process isolation. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map |
| OPC UA Client | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver. Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
## Per-driver documentation
- **Galaxy** has its own docs in this folder because the out-of-process architecture + MXAccess COM rules + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- [Galaxy.md](Galaxy.md) — COM bridge, STA pump, IPC, runtime probes
- [Galaxy-Repository.md](Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection
- **All other drivers** share a single per-driver specification in [docs/v2/driver-specs.md](../v2/driver-specs.md) — addressing, data-type maps, connection settings, and quirks live there. That file is the authoritative per-driver reference; this index points at it rather than duplicating.
## Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- [AB CIP](AbServer-Test-Fixture.md) — `ab_server` simulator, atomic-read smoke only; UDT / ALMD / family quirks are unit-only
- [Modbus](Modbus-Test-Fixture.md) — `pymodbus` + per-family profiles; best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — no integration fixture, unit-only via fake `IS7Client`
- [AB Legacy](AbLegacy-Test-Fixture.md) — no integration fixture, unit-only via `FakeAbLegacyTag` (libplctag PCCC)
- [TwinCAT](TwinCAT-Test-Fixture.md) — no integration fixture, unit-only via `FakeTwinCATClient` with native-notification harness
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — no integration fixture, unit-only via mocked `Session`; loopback against this repo's own server is the obvious next step
- [Galaxy](Galaxy-Test-Fixture.md) — richest harness: E2E Host subprocess + ZB SQL live-smoke + MXAccess opt-in
## Related cross-driver docs
- [HistoricalDataAccess.md](../HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The Galaxy driver's Aveva Historian implementation is the first; OPC UA Client forwards to the upstream server; other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering.
- [Subscriptions.md](../Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.