Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests
Joseph Doherty d8ef35d5bd Phase 3 PR 65 -- S7 ITagDiscovery + ISubscribable polling overlay + IHostConnectivityProbe. Three more capability interfaces on S7Driver, matching the Modbus driver's capability coverage. ITagDiscovery: DiscoverAsync streams every configured tag into IAddressSpaceBuilder under a single 'S7' folder; builder.Variable gets a DriverAttributeInfo carrying DriverDataType (MapDataType: Bool->Boolean, Byte/Int/UInt sizes->Int32 (until Core.Abstractions adds widths), Float32/Float64 direct, String + DateTime direct), SecurityClass (Operate if tag.Writable else ViewOnly -- matches the Modbus pattern so DriverNodeManager's ACL layer can gate writes per role without S7-specific logic), IsHistorized=false (S7 has no native historian surface), IsAlarm=false (S7 alarms land through TIA Portal's alarm-in-DB pattern which is per-site and out of scope for PR 65). ISubscribable polling overlay: same pattern Modbus established in PR 22. SubscribeAsync spawns a Task.Run loop that polls every tag, diffs against LastValues, raises OnDataChange on changes plus a force-raise on initial-data push per OPC UA Part 4 convention. Interval floored at 100ms -- S7 CPUs scan 2-10ms but process the comms mailbox at most once per scan, so sub-scan polling just queues wire-side with worse latency per S7netplus documented pattern. Poll errors tolerated: first-read fault doesn't kill the loop (caller can't receive initial values but subsequent polls try again); transient poll errors also swallowed so the loop survives a power-cycle + reconnect through the health surface. UnsubscribeAsync cancels the CTS + removes the subscription -- unknown handle is a no-op, not a throw, because the caller's race with server-side cleanup shouldn't crash either side. Shutdown tears down every subscription before disposing the Plc. IHostConnectivityProbe: HostName surfaced as host:port to match Modbus driver convention (Admin /hosts dashboard renders both families uniformly). GetHostStatuses returns one row (single-endpoint driver). ProbeLoopAsync serializes on the shared Gate + calls Plc.ReadStatusAsync (cheap Get-CPU-Status PDU that doubles as an 'is PLC up' check) every Probe.Interval with a Probe.Timeout cap, transitions HostState Unknown/Stopped -> Running on success and -> Stopped on any failure, raises OnHostStatusChanged only on actual transitions (no noise for steady-state probes). Probe loop starts at end of InitializeAsync when Probe.Enabled=true (default); Shutdown cancels the probe CTS. Initial state stays Unknown until first successful probe -- avoids broadcasting a premature Running before any PDU round-trip has happened. Unit tests (S7DiscoveryAndSubscribeTests, 4 facts): DiscoverAsync_projects_every_tag_into_the_address_space (3 tags + mixed writable/read-only -> Operate vs ViewOnly asserted), GetHostStatuses_returns_one_row_with_host_port_identity_pre_init, SubscribeAsync_returns_unique_handles_and_UnsubscribeAsync_accepts_them (diagnosticId uniqueness + idempotent double-unsubscribe), Subscribe_publishing_interval_is_floored_at_100ms (accepts 50ms request without throwing -- floor is applied internally). Uses a RecordingAddressSpaceBuilder stub that implements IVariableHandle.FullReference + MarkAsAlarmCondition (throws NotImplementedException since the S7 driver never calls it -- alarms out of scope). 57/57 S7 unit tests pass. dotnet build clean. All 5 capability interfaces (IDriver/ITagDiscovery/IReadable/IWritable/ISubscribable/IHostConnectivityProbe) now implemented -- the S7 driver surface is on par with the Modbus driver, minus the extended data types (Int64/UInt64/Float64/String/DateTime deferred per PR 64).
2026-04-19 00:16:10 -04:00
..
Phase 3 PR 63 -- S7AddressParser for DB/M/I/Q/T/C address strings. Adds S7AddressParser + S7ParsedAddress + S7Area + S7Size to the Driver.S7 project. Grammar follows driver-specs.md \u00A75 + Siemens TIA Portal / STEP 7 Classic convention: (1) Data blocks: DB{n}.DB{X|B|W|D}{offset}[.bit] where X=bit (requires .bit suffix 0-7), B=byte, W=word (16-bit), D=dword (32-bit). (2) Merkers: MB{n}, MW{n}, MD{n}, or M{n}.{bit} for bit access. (3) Inputs + Outputs: same {B|W|D} prefix or {n}.{bit} pattern as M. (4) Timers: T{n}. (5) Counters: C{n}. Output is an immutable S7ParsedAddress record struct with Area (DataBlock / Memory / Input / Output / Timer / Counter), DbNumber (only meaningful for DataBlock), Size (Bit / Byte / Word / DWord), ByteOffset (also timer/counter number when Area is Timer/Counter), BitOffset (0-7 for Size=Bit; 0 otherwise). Case-insensitive via ToUpperInvariant, whitespace trimmed on entry. Parse throws FormatException with the offending input echoed in the message; TryParse returns bool for config-validation callers that can't afford exceptions (e.g. Admin UI tag-editor live validation). Strict rejection policy -- 16 garbage cases covered in the theory test: empty/whitespace input, unknown area letter (Z0), DB without number/tail, DB bit size without .bit suffix, bit offset 8+, word/dword with .bit suffix, DB number 0 (must be >=1), non-numeric DB number, unknown size letter (Q), M without offset, M bit access without .bit, bit 8, negative offset, non-digit offset, non-numeric timer. Strict rejection surfaces config errors at driver-init time rather than as BadInternalError on every Read against the bad tag. No driver code wires through yet -- PR 64 is where IReadable/IWritable consume S7ParsedAddress and translate into S7netplus Plc.ReadAsync calls (the S7.Net address grammar is a strict subset of what we accept, and the parser's S7ParsedAddress is the bridge). Unit tests (S7AddressParserTests, 50 facts): parse-valid theories for DB/M/I/Q/T/C covering all size variants + edge bit offsets 0 and 7; case-insensitive + whitespace-trim theory; reject-invalid theory with 16 garbage cases; TryParse round-trip for valid and invalid inputs. 50/50 pass, dotnet build clean.
2026-04-19 00:06:24 -04:00
Phase 3 PR 65 -- S7 ITagDiscovery + ISubscribable polling overlay + IHostConnectivityProbe. Three more capability interfaces on S7Driver, matching the Modbus driver's capability coverage. ITagDiscovery: DiscoverAsync streams every configured tag into IAddressSpaceBuilder under a single 'S7' folder; builder.Variable gets a DriverAttributeInfo carrying DriverDataType (MapDataType: Bool->Boolean, Byte/Int/UInt sizes->Int32 (until Core.Abstractions adds widths), Float32/Float64 direct, String + DateTime direct), SecurityClass (Operate if tag.Writable else ViewOnly -- matches the Modbus pattern so DriverNodeManager's ACL layer can gate writes per role without S7-specific logic), IsHistorized=false (S7 has no native historian surface), IsAlarm=false (S7 alarms land through TIA Portal's alarm-in-DB pattern which is per-site and out of scope for PR 65). ISubscribable polling overlay: same pattern Modbus established in PR 22. SubscribeAsync spawns a Task.Run loop that polls every tag, diffs against LastValues, raises OnDataChange on changes plus a force-raise on initial-data push per OPC UA Part 4 convention. Interval floored at 100ms -- S7 CPUs scan 2-10ms but process the comms mailbox at most once per scan, so sub-scan polling just queues wire-side with worse latency per S7netplus documented pattern. Poll errors tolerated: first-read fault doesn't kill the loop (caller can't receive initial values but subsequent polls try again); transient poll errors also swallowed so the loop survives a power-cycle + reconnect through the health surface. UnsubscribeAsync cancels the CTS + removes the subscription -- unknown handle is a no-op, not a throw, because the caller's race with server-side cleanup shouldn't crash either side. Shutdown tears down every subscription before disposing the Plc. IHostConnectivityProbe: HostName surfaced as host:port to match Modbus driver convention (Admin /hosts dashboard renders both families uniformly). GetHostStatuses returns one row (single-endpoint driver). ProbeLoopAsync serializes on the shared Gate + calls Plc.ReadStatusAsync (cheap Get-CPU-Status PDU that doubles as an 'is PLC up' check) every Probe.Interval with a Probe.Timeout cap, transitions HostState Unknown/Stopped -> Running on success and -> Stopped on any failure, raises OnHostStatusChanged only on actual transitions (no noise for steady-state probes). Probe loop starts at end of InitializeAsync when Probe.Enabled=true (default); Shutdown cancels the probe CTS. Initial state stays Unknown until first successful probe -- avoids broadcasting a premature Running before any PDU round-trip has happened. Unit tests (S7DiscoveryAndSubscribeTests, 4 facts): DiscoverAsync_projects_every_tag_into_the_address_space (3 tags + mixed writable/read-only -> Operate vs ViewOnly asserted), GetHostStatuses_returns_one_row_with_host_port_identity_pre_init, SubscribeAsync_returns_unique_handles_and_UnsubscribeAsync_accepts_them (diagnosticId uniqueness + idempotent double-unsubscribe), Subscribe_publishing_interval_is_floored_at_100ms (accepts 50ms request without throwing -- floor is applied internally). Uses a RecordingAddressSpaceBuilder stub that implements IVariableHandle.FullReference + MarkAsAlarmCondition (throws NotImplementedException since the S7 driver never calls it -- alarms out of scope). 57/57 S7 unit tests pass. dotnet build clean. All 5 capability interfaces (IDriver/ITagDiscovery/IReadable/IWritable/ISubscribable/IHostConnectivityProbe) now implemented -- the S7 driver surface is on par with the Modbus driver, minus the extended data types (Int64/UInt64/Float64/String/DateTime deferred per PR 64).
2026-04-19 00:16:10 -04:00
Phase 3 PR 64 -- S7 IReadable + IWritable via S7.Net string-based Plc.ReadAsync/WriteAsync. Adds IReadable + IWritable capability interfaces to S7Driver, routing reads/writes through S7netplus's string-address API (Plc.ReadAsync(string, ct) / Plc.WriteAsync(string, object, ct)). All operations serialize on the class's SemaphoreSlim Gate because S7netplus mandates one Plc connection per PLC with client-side serialization -- parallel reads against a single S7 CPU queue wire-side anyway and just eat connection-resource budget. Supported data types in this PR: Bool, Byte, Int16, UInt16, Int32, UInt32, Float32. S7.Net's string-based read returns UNSIGNED boxed values (DBX=bool, DBB=byte, DBW=ushort, DBD=uint); the driver reinterprets them into the requested S7DataType via the (DataType, Size, raw) switch: unchecked short-cast for Int16, unchecked int-cast for Int32, BitConverter.UInt32BitsToSingle for Float32. Writes inverse the conversion -- Int16 -> unchecked ushort cast, Int32 -> unchecked uint cast, Float32 -> BitConverter.SingleToUInt32Bits -- before handing to S7.Net's WriteAsync. This avoids a second PLC round-trip that a typed ReadAsync(DataType, db, offset, VarType, ...) overload would need. Int64, UInt64, Float64, String, DateTime throw NotSupportedException (-> BadNotSupported StatusCode); S7 STRING has non-trivial header semantics + LReal/DateTime need typed S7.Net API paths, both land in a follow-up PR when scope demands. InitializeAsync now parses every tag's Address string via S7AddressParser at init time. Bad addresses throw FormatException and flip health to Faulted -- callers can't register a broken driver. The parsed form goes into _parsedByName so Read/Write can consult Size/BitOffset without re-parsing per operation. StatusCode mapping in catch chain: unknown tag name -> BadNodeIdUnknown (0x80340000), unsupported data type -> BadNotSupported (0x803D0000), read-only tag write attempt -> BadNotWritable (0x803B0000), S7.Net PlcException (carries PUT/GET-disabled signal on S7-1200/1500) -> BadDeviceFailure (0x80550000) so operators see a TIA-Portal config problem rather than a transient-fault false flag per driver-specs.md \u00A75, any other runtime exception on read -> BadCommunicationError (0x80050000) to distinguish socket/timeout from tag-level faults. Write generic-exception path stays BadInternalError because write failures can legitimately be driver-side value-range problems. Unit tests (S7DriverReadWriteTests, 3 facts): Initialize_rejects_invalid_tag_address_and_fails_fast -- Tags with a malformed address must throw at InitializeAsync rather than producing a half-healthy driver; ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequirePlc and throw the uniform 'not initialized' message. Wire-level round-trip coverage (integration test against a live S7-1500 or a mock S7 server) is deferred -- S7.Net doesn't ship an in-process fake and a conformant mock is non-trivial. 53/53 Modbus.Driver.S7.Tests pass (50 parser + 3 read/write). dotnet build clean.
2026-04-19 00:10:41 -04:00
Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.
2026-04-19 00:03:09 -04:00
Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.
2026-04-19 00:03:09 -04:00