Joseph Doherty a9b585ac5b Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward-
bridge) only proved driver-write → server-read. It missed:

 - OPC UA write → server → driver → PLC (the reverse direction)
 - server-side data-change notifications actually firing (a stale
   subscription can still let a read-after-the-fact return the new
   value and look fine)

Extend _common.ps1 with two helpers:

 - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s ->
   driver CLI read the PLC side, assert equality.
 - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the
   background with --duration N, settle 2s, driver-side write, wait for
   the subscription window to close, assert captured stdout contains
   the new value.

Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 /
test-focas / test-twincat after the existing forward-bridge stage.
Update README to describe the five-stage design + note that the
published NodeId must be writable for stages 4 + 5.

Also prepend UTF-8 BOM to every script in scripts/e2e so Windows
PowerShell 5.1 parsers agree on em-dash byte sequences the way
PowerShell 7 already does. The scripts still #Requires -Version 7.0 —
the BOM is purely defensive for IDE / CI step parsers.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 10:08:52 -04:00

95 lines
3.4 KiB
PowerShell

#Requires -Version 7.0
<#
.SYNOPSIS
End-to-end CLI test for the Modbus-TCP driver bridged through the OtOpcUa server.
.DESCRIPTION
Five assertions:
1. `otopcua-modbus-cli probe` hits the simulator
2. Driver-loopback write + read-back via modbus-cli
3. Forward bridge: modbus-cli writes HR[100], OPC UA client reads the bridged NodeId
4. Reverse bridge: OPC UA client writes the NodeId, modbus-cli reads HR[100]
5. Subscribe-sees-change: OPC UA subscription observes a modbus-cli write
Requires a running Modbus simulator on localhost:5502 (the pymodbus fixture
default per docs/drivers/Modbus-Test-Fixture.md) and a running OtOpcUa server
whose config DB has a Modbus DriverInstance bound to that simulator + a Tag
at HR[100] Int16 published under the NodeId passed via -BridgeNodeId.
.PARAMETER ModbusHost
Host:port of the Modbus simulator. Default 127.0.0.1:5502.
.PARAMETER OpcUaUrl
Endpoint URL of the OtOpcUa server. Default opc.tcp://localhost:4840.
.PARAMETER BridgeNodeId
OPC UA NodeId the OtOpcUa server publishes the HR[100] tag at. Set per your
server config — e.g. 'ns=2;s=/warsaw/modbus-sim/HR_100'. Required.
.EXAMPLE
.\test-modbus.ps1 -BridgeNodeId "ns=2;s=/warsaw/modbus-sim/HR_100"
#>
param(
[string]$ModbusHost = "127.0.0.1:5502",
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
[Parameter(Mandatory)] [string]$BridgeNodeId
)
$ErrorActionPreference = "Stop"
. "$PSScriptRoot/_common.ps1"
$hostPart, $portPart = $ModbusHost.Split(":")
$port = [int]$portPart
$modbusCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli" `
-ExeName "otopcua-modbus-cli"
$opcUaCli = Get-CliInvocation `
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
-ExeName "otopcua-cli"
$commonModbus = @("-h", $hostPart, "-p", $port)
$results = @()
$results += Test-Probe `
-Cli $modbusCli `
-ProbeArgs (@("probe") + $commonModbus)
$writeValue = Get-Random -Minimum 1 -Maximum 9999
$results += Test-DriverLoopback `
-Cli $modbusCli `
-WriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $writeValue)) `
-ReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16")) `
-ExpectedValue "$writeValue"
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
$results += Test-ServerBridge `
-DriverCli $modbusCli `
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $bridgeValue)) `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-ExpectedValue "$bridgeValue"
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
$results += Test-OpcUaWriteBridge `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $modbusCli `
-DriverReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16")) `
-ExpectedValue "$reverseValue"
$subValue = Get-Random -Minimum 30000 -Maximum 39999
$results += Test-SubscribeSeesChange `
-OpcUaCli $opcUaCli `
-OpcUaUrl $OpcUaUrl `
-OpcUaNodeId $BridgeNodeId `
-DriverCli $modbusCli `
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $subValue)) `
-ExpectedValue "$subValue"
Write-Summary -Title "Modbus e2e" -Results $results
if ($results | Where-Object { -not $_.Passed }) { exit 1 }