The original three-stage design (probe / driver-loopback / forward- bridge) only proved driver-write → server-read. It missed: - OPC UA write → server → driver → PLC (the reverse direction) - server-side data-change notifications actually firing (a stale subscription can still let a read-after-the-fact return the new value and look fine) Extend _common.ps1 with two helpers: - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s -> driver CLI read the PLC side, assert equality. - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the background with --duration N, settle 2s, driver-side write, wait for the subscription window to close, assert captured stdout contains the new value. Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 / test-focas / test-twincat after the existing forward-bridge stage. Update README to describe the five-stage design + note that the published NodeId must be writable for stages 4 + 5. Also prepend UTF-8 BOM to every script in scripts/e2e so Windows PowerShell 5.1 parsers agree on em-dash byte sequences the way PowerShell 7 already does. The scripts still #Requires -Version 7.0 — the BOM is purely defensive for IDE / CI step parsers. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
95 lines
3.4 KiB
PowerShell
95 lines
3.4 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the Modbus-TCP driver bridged through the OtOpcUa server.
|
|
|
|
.DESCRIPTION
|
|
Five assertions:
|
|
1. `otopcua-modbus-cli probe` hits the simulator
|
|
2. Driver-loopback write + read-back via modbus-cli
|
|
3. Forward bridge: modbus-cli writes HR[100], OPC UA client reads the bridged NodeId
|
|
4. Reverse bridge: OPC UA client writes the NodeId, modbus-cli reads HR[100]
|
|
5. Subscribe-sees-change: OPC UA subscription observes a modbus-cli write
|
|
|
|
Requires a running Modbus simulator on localhost:5502 (the pymodbus fixture
|
|
default per docs/drivers/Modbus-Test-Fixture.md) and a running OtOpcUa server
|
|
whose config DB has a Modbus DriverInstance bound to that simulator + a Tag
|
|
at HR[100] Int16 published under the NodeId passed via -BridgeNodeId.
|
|
|
|
.PARAMETER ModbusHost
|
|
Host:port of the Modbus simulator. Default 127.0.0.1:5502.
|
|
|
|
.PARAMETER OpcUaUrl
|
|
Endpoint URL of the OtOpcUa server. Default opc.tcp://localhost:4840.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
OPC UA NodeId the OtOpcUa server publishes the HR[100] tag at. Set per your
|
|
server config — e.g. 'ns=2;s=/warsaw/modbus-sim/HR_100'. Required.
|
|
|
|
.EXAMPLE
|
|
.\test-modbus.ps1 -BridgeNodeId "ns=2;s=/warsaw/modbus-sim/HR_100"
|
|
#>
|
|
|
|
param(
|
|
[string]$ModbusHost = "127.0.0.1:5502",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
$hostPart, $portPart = $ModbusHost.Split(":")
|
|
$port = [int]$portPart
|
|
|
|
$modbusCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli" `
|
|
-ExeName "otopcua-modbus-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonModbus = @("-h", $hostPart, "-p", $port)
|
|
$results = @()
|
|
|
|
$results += Test-Probe `
|
|
-Cli $modbusCli `
|
|
-ProbeArgs (@("probe") + $commonModbus)
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $modbusCli `
|
|
-WriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $modbusCli `
|
|
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
|
$results += Test-OpcUaWriteBridge `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $modbusCli `
|
|
-DriverReadArgs (@("read") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16")) `
|
|
-ExpectedValue "$reverseValue"
|
|
|
|
$subValue = Get-Random -Minimum 30000 -Maximum 39999
|
|
$results += Test-SubscribeSeesChange `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $modbusCli `
|
|
-DriverWriteArgs (@("write") + $commonModbus + @("-r", "HoldingRegisters", "-a", "100", "-t", "UInt16", "-v", $subValue)) `
|
|
-ExpectedValue "$subValue"
|
|
|
|
Write-Summary -Title "Modbus e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|