The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
57 lines
2.1 KiB
JSON
57 lines
2.1 KiB
JSON
{
|
|
"$comment": "Copy this file to e2e-config.json and replace the NodeIds with the ones your Config DB publishes. Fields named `opcUaUrl` override the -OpcUaUrl parameter on test-all.ps1 per-driver. Omit a top-level key to skip that driver.",
|
|
|
|
"modbus": {
|
|
"endpoint": "127.0.0.1:5502",
|
|
"bridgeNodeId": "ns=2;s=Modbus/HR100",
|
|
"opcUaUrl": "opc.tcp://localhost:4840"
|
|
},
|
|
|
|
"abcip": {
|
|
"gateway": "ab://127.0.0.1/1,0",
|
|
"family": "ControlLogix",
|
|
"tagPath": "TestDINT",
|
|
"bridgeNodeId": "ns=2;s=AbCip/TestDINT"
|
|
},
|
|
|
|
"ablegacy": {
|
|
"$comment": "Gated behind AB_LEGACY_TRUST_WIRE=1 — ab_server PCCC path upstream-broken, needs real SLC / MicroLogix / PLC-5 or RSEmulate 500.",
|
|
"gateway": "ab://192.168.1.10/1,0",
|
|
"plcType": "Slc500",
|
|
"address": "N7:5",
|
|
"bridgeNodeId": "ns=2;s=AbLegacy/N7_5"
|
|
},
|
|
|
|
"s7": {
|
|
"endpoint": "127.0.0.1:102",
|
|
"cpu": "S71500",
|
|
"slot": 0,
|
|
"address": "DB1.DBW0",
|
|
"bridgeNodeId": "ns=2;s=S7/DB1_DBW0"
|
|
},
|
|
|
|
"focas": {
|
|
"$comment": "Gated behind FOCAS_TRUST_WIRE=1 — no public simulator. Point at a real CNC + ensure Fwlib32.dll is on PATH.",
|
|
"host": "192.168.1.20",
|
|
"port": 8193,
|
|
"address": "R100",
|
|
"bridgeNodeId": "ns=2;s=Focas/R100"
|
|
},
|
|
|
|
"twincat": {
|
|
"$comment": "Gated behind TWINCAT_TRUST_WIRE=1 — needs XAR or standalone TwinCAT Router NuGet reachable at -AmsNetId.",
|
|
"amsNetId": "127.0.0.1.1.1",
|
|
"amsPort": 851,
|
|
"symbolPath": "MAIN.iCounter",
|
|
"bridgeNodeId": "ns=2;s=TwinCAT/MAIN_iCounter"
|
|
},
|
|
|
|
"phase7": {
|
|
"$comment": "Virtual tags + scripted alarms. The VirtualNodeId must resolve to a server-side virtual tag whose script reads the modbus InputNodeId and writes VT = input * 2. The AlarmNodeId is the ConditionId of a scripted alarm that fires when VT > 100.",
|
|
"modbusEndpoint": "127.0.0.1:5502",
|
|
"inputNodeId": "ns=2;s=Modbus/HR100",
|
|
"virtualNodeId": "ns=2;s=Virtual/VT_DoubledHR100",
|
|
"alarmNodeId": "ns=2;s=Alarm/HR100_High"
|
|
}
|
|
}
|