lmxopcua/docs/plans/2026-07-24-modbus-rtu-driver.md
T
Joseph Doherty 76e55fc112 docs(drivers): Wave 0-2 tracking doc + Wave 1/2 implementation plans
Add a living progress tracker (docs/plans/2026-07-24-driver-expansion-tracking.md)
for the driver-expansion program's Waves 0-2, linked from the program design doc's
document map. One row per deliverable pointing at design + implementation plan + status.

Add executable implementation plans (plan .md + co-located .tasks.json) for the four
Wave 1/2 drivers, each authored by writing-plans methodology off its design doc and
mirroring the relevant existing driver:

- Modbus RTU        11 tasks  (extends Driver.Modbus; RTU-over-TCP, direct-serial descoped)
- SQL poll          22 tasks  (ISqlDialect seam, SQL Server only in v1; SQLite + central-SQL fixtures)
- MTConnect Agent   23 tasks  (browse free via Wave-0 seam; TrakHound-vs-hand-rolled = Task 0)
- MQTT/Sparkplug B  27 tasks  (P1 plain MQTT 0-14 then P2 Sparkplug 15-26; MQTTnet-5 pinning spike = Task 0)

Wave 0 (universal browser) remains merged (056887d6) with its live gate open (#468).
All four new plans are design-only -> plan-ready; nothing built yet.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:17:44 -04:00

730 lines
40 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Modbus RTU Driver Implementation Plan
> **For Claude:** REQUIRED SUB-SKILL: Use superpowers-extended-cc:executing-plans (or subagent-driven-development) to implement this plan task-by-task.
**Goal:** Add a Modbus **RTU-over-TCP** transport (RTU CRC-16 framing tunnelled to a serial→Ethernet gateway) to the existing `ModbusDriver`, selected by a new `Transport` config field — reusing every codec/planner/health/materialisation surface unchanged.
**Architecture:** Purely additive behind the existing `IModbusTransport` seam. The application protocol (function codes, codecs, planner, coalescing, write path, probe, materialisation, HistoryRead) is byte-for-byte identical across TCP and RTU — only the wire framing differs (`[addr][PDU][CRC-16]`, no MBAP, no TxId). Work = a CRC-16 helper + a length-less FC-aware framer + one new socket transport that composes a socket lifecycle extracted from `ModbusTcpTransport` + a transport-mode selector on the config + one AdminUI field. **Zero** changes to codecs/planner/health.
**Tech Stack:** existing `ZB.MOM.WW.OtOpcUa.Driver.Modbus` (+ `.Contracts`, `.Addressing`), xUnit + Shouldly, `pymodbus[simulator]==3.13.0` Docker fixture (RTU-framed-TCP profile; stdlib fallback server modelled on `exception_injector.py`), Blazor `ModbusDriverForm.razor` (AdminUI). No new NuGet dependency.
**Source design:** docs/plans/2026-07-15-modbus-rtu-driver-design.md
**Program design:** docs/plans/2026-07-15-driver-expansion-program-design.md (§3 shared contract, §7 fixtures) — this is **Wave 1**.
**Progress tracker:** docs/plans/2026-07-24-driver-expansion-tracking.md
## Scope (P1 shippable v1 only)
RTU-over-TCP via a serial→Ethernet gateway (Moxa/Digi/Lantronix), RTU CRC-16 (poly `0xA001`) + FC-aware length framing, a `Transport` selector (`Tcp` | `RtuOverTcp`) on the Modbus config, the `rtu_over_tcp` pymodbus docker profile, and the AdminUI selector. Read **and** write supported (same as TCP).
## Deferred / out of scope
- **Direct-serial transport** (`ModbusRtuTransport` / `System.IO.Ports`) — descoped (user, 2026-07-15). RTU buses are reached exclusively via a serial→Ethernet gateway. Design record kept in **design §2b / §9 P2**; the `ModbusRtuFraming` built here is byte-stream-agnostic so a future serial leg would reuse it unchanged. Do **not** number-squat an `Rtu` enum member for it.
- **Modbus ASCII** — a third framing (`:`-delimited hex + LRC); would be another `IModbusTransport` if ever needed (design §2c). Not planned.
- **Per-tag `TagConfig` changes** — none. `ModbusTagDefinition`/`ModbusTagDto` already carry the per-tag `UnitId` override that makes an RS-485 multi-drop bus work; the read planner already refuses to coalesce across UnitIds. Additions are **driver-level only** (design §4).
- **`ModbusDriver.BuildSlaveHostName` change** — NOT needed. It already emits `host:port/unit{n}`, the correct per-slave resilience key for a gateway (design §6). The design §1 table listed it only for the descoped serial (COM) case.
## Cross-cutting rules (program §3.1 — mandatory)
- **Enum-serialization trap** — `Transport` MUST round-trip as a **name string**, never a number, on both the AdminUI serializer (`ModbusDriverForm._jsonOpts` already carries `JsonStringEnumConverter`) and the factory (DTO field typed `string?`, parsed via the existing `ParseEnum<T>` — mirror `Family`/`MelsecSubFamily`; **do not** type the DTO field as the enum). Guarded by an explicit `"transport":"RtuOverTcp"` string assertion (design §5).
- **Per-op deadline (R2-01)** — the RTU transport MUST run every transaction under a linked-CTS `CancelAfter(Options.Timeout)` — a frozen gateway must never wedge a poll. There is **no MBAP length field to trust**; FC-aware sizing is the only length signal, so getting it right (or timing out) is the top correctness risk (design §7).
- **Single-flight mandatory on RTU** — no TxId means at most one transaction on the bus at a time. Keep the `_gate` `SemaphoreSlim` in the new transport.
- **Ctor is connection-free** — the transport constructor must not connect; all I/O happens in `ConnectAsync`/`SendAsync`.
- **Live-verify discipline** — the picker/editor + deploy path get a docker-dev `/run` before trust (Task 10).
---
## Task 0: Add the `ModbusTransportMode` enum
**Classification:** trivial
**Estimated implement time:** ~3 min
**Parallelizable with:** Task 1, Task 3
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Contracts/ModbusTransportMode.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusTransportModeTests.cs`
The enum lives in `.Contracts` (backend-dep-free), namespace `ZB.MOM.WW.OtOpcUa.Driver.Modbus` — same namespace as `ModbusDriverOptions`.
**Step 1 — failing test:**
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusTransportModeTests
{
[Fact]
public void Tcp_is_the_default_zero_member()
=> ((ModbusTransportMode)0).ShouldBe(ModbusTransportMode.Tcp);
[Fact]
public void Exactly_two_members_ship_in_v1()
=> Enum.GetNames<ModbusTransportMode>().ShouldBe(["Tcp", "RtuOverTcp"]);
}
```
**Step 2 — run & expect FAIL** (type does not exist / does not compile):
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusTransportModeTests"`
**Step 3 — minimal impl:**
```csharp
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
/// <summary>
/// Wire transport for a Modbus driver instance. <see cref="Tcp"/> = Modbus/TCP (MBAP + TxId);
/// <see cref="RtuOverTcp"/> = RTU framing (address + CRC-16, no MBAP) tunnelled over a socket to
/// a serial→Ethernet gateway. Default <see cref="Tcp"/> — existing configs omit the field.
/// A direct-serial <c>Rtu</c> member is intentionally NOT reserved here (descoped 2026-07-15);
/// do not number-squat it.
/// </summary>
public enum ModbusTransportMode
{
/// <summary>Modbus/TCP — 7-byte MBAP header + transaction id (the historical default).</summary>
Tcp,
/// <summary>RTU framing (<c>[addr][PDU][CRC-16]</c>) tunnelled over a socket to a serial→Ethernet gateway.</summary>
RtuOverTcp,
}
```
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add ModbusTransportMode enum (Tcp | RtuOverTcp)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 1: `ModbusCrc` — CRC-16 (poly 0xA001) helper + golden vectors
**Classification:** small
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 0, Task 3
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusCrc.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusCrcTests.cs`
CRC-16/MODBUS: reflected poly `0xA001`, init `0xFFFF`, appended **low byte first**. This is the top-of-stack of the length-less framer — golden vectors are the whole point.
**Step 1 — failing test** (table-driven against published Modbus CRC vectors):
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusCrcTests
{
// Known CRC-16/MODBUS vectors (init 0xFFFF, poly 0xA001). CRC returned as ushort;
// on the wire it is appended low-byte-first.
[Theory]
// FC03 read HR: unit 1, addr 0, qty 1 -> CRC 0x0A84 (bytes 84 0A on the wire)
[InlineData(new byte[] { 0x01, 0x03, 0x00, 0x00, 0x00, 0x01 }, (ushort)0x0A84)]
// "123456789" canonical check value for CRC-16/MODBUS = 0x4B37
[InlineData(new byte[] { 0x31,0x32,0x33,0x34,0x35,0x36,0x37,0x38,0x39 }, (ushort)0x4B37)]
public void Compute_matches_known_vectors(byte[] frame, ushort expected)
=> ModbusCrc.Compute(frame).ShouldBe(expected);
[Fact]
public void AppendLowByteFirst_writes_lo_then_hi()
{
var body = new byte[] { 0x01, 0x03, 0x00, 0x00, 0x00, 0x01 };
var withCrc = ModbusCrc.Append(body);
withCrc.Length.ShouldBe(body.Length + 2);
withCrc[^2].ShouldBe((byte)0x84); // CRC low byte
withCrc[^1].ShouldBe((byte)0x0A); // CRC high byte
}
}
```
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusCrcTests"`
**Step 3 — minimal impl** (`ModbusCrc.cs`): a `static ushort Compute(ReadOnlySpan<byte>)` (init `0xFFFF`, xor byte, 8× shift-right, xor `0xA001` on carry) and `static byte[] Append(ReadOnlySpan<byte> body)` returning `body + [crc & 0xFF, crc >> 8]`. ~30 lines. If a golden vector disagrees, fix the CRC math — never the vector.
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add ModbusCrc CRC-16/MODBUS helper + golden vectors
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 2: `ModbusRtuFraming` — ADU build + FC-aware length-less deframe
**Classification:** high-risk (framing)
**Estimated implement time:** ~5 min
**Parallelizable with:** none
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusRtuFraming.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusRtuFramingTests.cs`
The one genuinely new correctness risk (design §2a/§7): RTU frames carry **no length field**, so response size is parsed from the function code. Read `addr(1)`+`fc(1)`, then: **exception** (`fc & 0x80`) → `excCode(1)+CRC(2)`; **reads FC01/02/03/04**`byteCount(1)` then `byteCount + CRC(2)`; **write echoes FC05/06/15/16** → fixed `4 + CRC(2)`. Validate trailing CRC, strip `addr`+`CRC`, return the bare PDU `[fc, ...data]`. CRC mismatch / truncation → `ModbusTransportDesyncException`; exception PDU (after CRC-validate) → `ModbusException`. Test directly against an in-memory `MemoryStream` of canned bytes.
**Step 1 — failing test:**
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusRtuFramingTests
{
private static MemoryStream Canned(params byte[] frame) => new(frame);
[Fact]
public void BuildAdu_prefixes_unit_and_appends_crc()
{
var adu = ModbusRtuFraming.BuildAdu(0x01, new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 });
adu.ShouldBe(new byte[] { 0x01, 0x03, 0x00, 0x00, 0x00, 0x01, 0x84, 0x0A });
}
[Fact]
public async Task ReadResponse_FC03_returns_bare_pdu()
{
// addr=01 fc=03 byteCount=02 data=00 0A + CRC(lo,hi)
var body = new byte[] { 0x01, 0x03, 0x02, 0x00, 0x0A };
var frame = ModbusCrc.Append(body);
await using var s = Canned(frame);
var pdu = await ModbusRtuFraming.ReadResponsePduAsync(s, 0x01, TestContext.Current.CancellationToken);
pdu.ShouldBe(new byte[] { 0x03, 0x02, 0x00, 0x0A }); // fc + byteCount + data, no addr/CRC
}
[Fact]
public async Task ReadResponse_exception_frame_throws_ModbusException()
{
// addr=01 fc=0x83 exc=0x02 + CRC
var frame = ModbusCrc.Append(new byte[] { 0x01, 0x83, 0x02 });
await using var s = Canned(frame);
var ex = await Should.ThrowAsync<ModbusException>(
ModbusRtuFraming.ReadResponsePduAsync(s, 0x01, TestContext.Current.CancellationToken));
ex.FunctionCode.ShouldBe((byte)0x03);
ex.ExceptionCode.ShouldBe((byte)0x02);
}
[Fact]
public async Task ReadResponse_bad_crc_throws_desync()
{
var frame = ModbusCrc.Append(new byte[] { 0x01, 0x03, 0x02, 0x00, 0x0A });
frame[^1] ^= 0xFF; // corrupt CRC high byte
await using var s = Canned(frame);
await Should.ThrowAsync<ModbusTransportDesyncException>(
ModbusRtuFraming.ReadResponsePduAsync(s, 0x01, TestContext.Current.CancellationToken));
}
[Fact]
public async Task ReadResponse_FC06_write_echo_returns_four_byte_pdu()
{
// addr=01 fc=06 addr=00 07 value=00 2A + CRC -> PDU = 06 00 07 00 2A
var frame = ModbusCrc.Append(new byte[] { 0x01, 0x06, 0x00, 0x07, 0x00, 0x2A });
await using var s = Canned(frame);
var pdu = await ModbusRtuFraming.ReadResponsePduAsync(s, 0x01, TestContext.Current.CancellationToken);
pdu.ShouldBe(new byte[] { 0x06, 0x00, 0x07, 0x00, 0x2A });
}
}
```
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusRtuFramingTests"`
**Step 3 — minimal impl** (`ModbusRtuFraming.cs`): `static byte[] BuildAdu(byte unitId, ReadOnlySpan<byte> pdu)` = `ModbusCrc.Append([unitId, ..pdu])`; `static async Task<byte[]> ReadResponsePduAsync(Stream, byte expectedUnit, CancellationToken)` doing the FC-aware read described above with a `ReadExactlyAsync` helper (mirror `ModbusTcpTransport.ReadExactlyAsync`). Reuse `ModbusException` + `ModbusTransportDesyncException` (both already in the project). Keep framing byte-stream-agnostic (no socket knowledge) so a future serial transport can reuse it.
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add ModbusRtuFraming (ADU build + FC-aware length-less deframe)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 3: Extract `ModbusSocketLifecycle` from `ModbusTcpTransport` (behaviour-preserving)
**Classification:** high-risk (transport / concurrency)
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 0, Task 1, Task 2
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusSocketLifecycle.cs`
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusTcpTransport.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusSocketLifecycleTests.cs`
Mechanical refactor: move the IPv4-preference connect (`ConnectAsync`), `EnableKeepAlive`/`ClampToWholeSeconds`, `ConnectWithBackoffAsync`, `TearDownAsync`, and the `_lastSuccessUtc`/idle-disconnect tracking out of `ModbusTcpTransport` into a reusable `ModbusSocketLifecycle` that exposes the current `NetworkStream`. `ModbusTcpTransport` keeps its MBAP `SendOnceAsync` and composes the lifecycle. **Behaviour must be byte-for-byte unchanged** — the existing `ModbusTcpReconnectTests` + `ModbusConnectionOptionsTests` are the regression net; run the whole Modbus.Tests suite green before committing.
**Step 1 — failing test** (pins the extracted surface; `ClampToWholeSeconds` moves with it):
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusSocketLifecycleTests
{
[Theory]
[InlineData(0.4, 1)] // sub-second rounds up to 1 (the int-cast truncation guard)
[InlineData(2.0, 2)]
[InlineData(-5.0, 1)] // negative clamps to 1
public void ClampToWholeSeconds_rounds_up_min_one(double seconds, int expected)
=> ModbusSocketLifecycle.ClampToWholeSeconds(TimeSpan.FromSeconds(seconds)).ShouldBe(expected);
[Fact]
public async Task Connect_to_dead_port_surfaces_socket_failure()
{
var life = new ModbusSocketLifecycle("127.0.0.1", 1, TimeSpan.FromMilliseconds(300),
autoReconnect: false);
await Should.ThrowAsync<System.Net.Sockets.SocketException>(
life.ConnectAsync(TestContext.Current.CancellationToken));
}
}
```
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusSocketLifecycleTests"`
**Step 3 — minimal impl:** create `ModbusSocketLifecycle` holding `_host/_port/_timeout/_autoReconnect/_keepAlive/_idleDisconnect/_reconnect`, the `TcpClient`/`NetworkStream`, and `_lastSuccessUtc`; expose `ConnectAsync`, `ConnectWithBackoffAsync`, `TearDownAsync`, `Stream` (current), `MarkSuccess()`, `ShouldReconnectForIdle()`, and the `static int ClampToWholeSeconds`. Re-point `ModbusTcpTransport` to delegate connect/reconnect/teardown/idle to it while keeping MBAP `SendOnceAsync` in place. Move (don't duplicate) `ClampToWholeSeconds` — update its one internal caller/test reference.
**Step 4 — run & expect PASS** — then run the **whole** suite to prove no regression:
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests`
**Step 5 — commit:**
`git commit -am "refactor(modbus): extract ModbusSocketLifecycle from ModbusTcpTransport (behaviour-preserving)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 4: `ModbusRtuOverTcpTransport` — RTU framing over the socket lifecycle
**Classification:** high-risk (framing / transport / concurrency)
**Estimated implement time:** ~5 min
**Parallelizable with:** none
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusRtuOverTcpTransport.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusRtuOverTcpTransportTests.cs`
`IModbusTransport` implementation: composes `ModbusSocketLifecycle` (Task 3) for connect/reconnect/keepalive/idle and `ModbusRtuFraming` (Task 2) for send/receive. Delta from `ModbusTcpTransport`: CRC framing instead of MBAP, **no TxId**. Keep the `_gate` `SemaphoreSlim` single-flight (mandatory — no TxId), the single reconnect-retry shape, and a linked-CTS `CancelAfter(Options.Timeout)` per-op deadline (design §7, R2-01). **Seam choice for unit test:** add an `internal` test ctor accepting a pre-connected `Stream` (an in-memory duplex fake) that bypasses `ConnectAsync` — this is "the fake one level below the `IModbusTransport` fakes" the design §8 calls for, and lets the send/receive orchestration + single-flight + deadline be tested with no socket.
**Step 1 — failing test** (duplex fake: canned response stream + capture of written request bytes):
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusRtuOverTcpTransportTests
{
[Fact]
public async Task SendAsync_writes_rtu_adu_and_returns_deframed_pdu()
{
// Response the fake gateway will emit: FC03, 1 reg = 0x000A.
var response = ModbusCrc.Append(new byte[] { 0x01, 0x03, 0x02, 0x00, 0x0A });
var fake = new CapturingDuplexStream(response);
await using var transport = ModbusRtuOverTcpTransport.ForTest(fake, TimeSpan.FromSeconds(2));
var pdu = await transport.SendAsync(0x01, new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 },
TestContext.Current.CancellationToken);
pdu.ShouldBe(new byte[] { 0x03, 0x02, 0x00, 0x0A });
// The request went out as an RTU ADU: unit + pdu + CRC, NO MBAP header.
fake.Written.ShouldBe(new byte[] { 0x01, 0x03, 0x00, 0x00, 0x00, 0x01, 0x84, 0x0A });
}
[Fact]
public async Task SendAsync_exception_pdu_surfaces_ModbusException()
{
var response = ModbusCrc.Append(new byte[] { 0x01, 0x83, 0x02 });
var fake = new CapturingDuplexStream(response);
await using var transport = ModbusRtuOverTcpTransport.ForTest(fake, TimeSpan.FromSeconds(2));
await Should.ThrowAsync<ModbusException>(
transport.SendAsync(0x01, new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 },
TestContext.Current.CancellationToken));
}
[Fact]
public async Task SendAsync_stalled_gateway_hits_per_op_deadline()
{
var fake = new CapturingDuplexStream(respondBytes: Array.Empty<byte>(), stall: true);
await using var transport = ModbusRtuOverTcpTransport.ForTest(fake, TimeSpan.FromMilliseconds(200));
await Should.ThrowAsync<ModbusTransportDesyncException>(
transport.SendAsync(0x01, new byte[] { 0x03, 0x00, 0x00, 0x00, 0x01 },
TestContext.Current.CancellationToken));
}
}
```
(The `CapturingDuplexStream` test double — a `Stream` that records writes and replays `respondBytes` on read, or blocks forever when `stall` — lives in the test file.)
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusRtuOverTcpTransportTests"`
**Step 3 — minimal impl:** production ctor takes the same connection params as `ModbusTcpTransport` and builds a `ModbusSocketLifecycle`; `internal static ForTest(Stream, TimeSpan)` injects a pre-connected stream. `SendAsync`: `_gate.WaitAsync`; idle-reconnect check (skipped in test seam); write `ModbusRtuFraming.BuildAdu(unitId, pdu)`, flush, `ModbusRtuFraming.ReadResponsePduAsync(...)` under a linked `CancelAfter(_timeout)`; timeout-vs-caller-cancel distinction + teardown mirror `ModbusTcpTransport.SendOnceAsync`; single reconnect-retry on socket-level failure.
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add ModbusRtuOverTcpTransport (RTU framing over socket lifecycle)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 5: `ModbusTransportFactory.Create` — switch on `Transport`
**Classification:** small
**Estimated implement time:** ~4 min
**Parallelizable with:** Task 6
**Files:**
- Create: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusTransportFactory.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusTransportFactoryTests.cs`
One place that maps `ModbusDriverOptions` → the right `IModbusTransport`, consumed by both the driver default closure (Task 7) and the probe (Task 7). `Tcp``ModbusTcpTransport`, `RtuOverTcp``ModbusRtuOverTcpTransport`; both get `Host/Port/Timeout/AutoReconnect/KeepAlive/IdleDisconnect/Reconnect`.
**Step 1 — failing test:**
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusTransportFactoryTests
{
[Fact]
public void Tcp_mode_builds_tcp_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions { Transport = ModbusTransportMode.Tcp })
.ShouldBeOfType<ModbusTcpTransport>();
[Fact]
public void RtuOverTcp_mode_builds_rtu_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions { Transport = ModbusTransportMode.RtuOverTcp })
.ShouldBeOfType<ModbusRtuOverTcpTransport>();
[Fact]
public void Default_options_build_tcp_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions())
.ShouldBeOfType<ModbusTcpTransport>();
}
```
(Depends on Task 6's `Transport` property existing on `ModbusDriverOptions` — sequence Task 6 or add the property first. If Task 5 lands before Task 6, add the property in this task instead.)
**Step 2 — run & expect FAIL.**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusTransportFactoryTests"`
**Step 3 — minimal impl:** `static IModbusTransport Create(ModbusDriverOptions o)` = `switch (o.Transport) { RtuOverTcp => new ModbusRtuOverTcpTransport(...), _ => new ModbusTcpTransport(...) }`, passing the shared connection params.
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add ModbusTransportFactory switch on Transport mode
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 6: Add `Transport` to options + DTO + factory (string-enum guard)
**Classification:** small
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 5
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Contracts/ModbusDriverOptions.cs`
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusDriverFactoryExtensions.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusTransportConfigRoundTripTests.cs`
Add `public ModbusTransportMode Transport { get; init; } = ModbusTransportMode.Tcp;` to `ModbusDriverOptions`. On the DTO: add `public string? Transport { get; init; }` (typed **`string?`**, per the Modbus factory pattern — design §5) and map it with the existing `ParseEnum<ModbusTransportMode>(...)` helper, defaulting to `Tcp` when null. The guard test asserts the string wire form.
**Step 1 — failing test:**
```csharp
using System.Text.Json;
using System.Text.Json.Serialization;
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusTransportConfigRoundTripTests
{
// Mirrors the AdminUI ModbusDriverForm serializer: camelCase + string enums.
private static readonly JsonSerializerOptions _adminOpts = new()
{
PropertyNamingPolicy = JsonNamingPolicy.CamelCase,
Converters = { new JsonStringEnumConverter() },
};
[Fact]
public void Transport_serializes_as_a_string_not_a_number()
{
var opts = new ModbusDriverOptions { Host = "10.20.0.50", Port = 4001, Transport = ModbusTransportMode.RtuOverTcp };
var json = JsonSerializer.Serialize(opts, _adminOpts);
json.ShouldContain("\"transport\":\"RtuOverTcp\"");
json.ShouldNotContain("\"transport\":1", Case.Sensitive);
}
[Fact]
public void Factory_binds_RtuOverTcp_from_string_config()
{
const string json = """{ "host": "10.20.0.50", "port": 4001, "transport": "RtuOverTcp" }""";
using var driver = ModbusDriverFactoryExtensions.CreateInstance("mb-rtu", json);
var opts = (ModbusDriverOptions)typeof(ModbusDriver)
.GetField("_options", System.Reflection.BindingFlags.NonPublic | System.Reflection.BindingFlags.Instance)!
.GetValue(driver)!;
opts.Transport.ShouldBe(ModbusTransportMode.RtuOverTcp);
}
[Fact]
public void Factory_defaults_Transport_to_Tcp_when_omitted()
{
const string json = """{ "host": "10.0.0.10" }""";
using var driver = ModbusDriverFactoryExtensions.CreateInstance("mb-tcp", json);
var opts = (ModbusDriverOptions)typeof(ModbusDriver)
.GetField("_options", System.Reflection.BindingFlags.NonPublic | System.Reflection.BindingFlags.Instance)!
.GetValue(driver)!;
opts.Transport.ShouldBe(ModbusTransportMode.Tcp);
}
}
```
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusTransportConfigRoundTripTests"`
**Step 3 — minimal impl:** add the `Transport` property (options) + DTO `string?` field + factory mapping `Transport = dto.Transport is null ? ModbusTransportMode.Tcp : ParseEnum<ModbusTransportMode>(dto.Transport, "<driver-level>", driverInstanceId, "Transport")`.
**Step 4 — run & expect PASS.**
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): bind Transport mode on options/DTO/factory (string-enum guard)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 7: Wire the driver default closure + probe to `ModbusTransportFactory`
**Classification:** small
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 8
**Files:**
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusDriver.cs`
- Modify: `src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus/ModbusDriverProbe.cs`
- Test: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusTransportWiringTests.cs`
Replace the driver ctor's hardcoded `new ModbusTcpTransport(...)` default closure with `o => ModbusTransportFactory.Create(o)`. In the probe, replace the hardcoded `new ModbusTcpTransport(host, port, timeout, autoReconnect: false)` (line ~77) with a factory build carrying `Transport` (parse it into `ProbeTarget` from the DTO), `autoReconnect: false`. Now an `RtuOverTcp`-authored config probes over RTU framing — matching how it will actually run.
**Step 1 — failing test** (the default closure honours the mode; the probe carries it):
```csharp
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusTransportWiringTests
{
private static IModbusTransport BuildDefaultTransport(ModbusDriverOptions opts)
{
using var driver = new ModbusDriver(opts, "wire-test");
var factory = (Func<ModbusDriverOptions, IModbusTransport>)typeof(ModbusDriver)
.GetField("_transportFactory", System.Reflection.BindingFlags.NonPublic | System.Reflection.BindingFlags.Instance)!
.GetValue(driver)!;
return factory(opts);
}
[Fact]
public void Default_closure_builds_rtu_transport_for_RtuOverTcp()
=> BuildDefaultTransport(new ModbusDriverOptions { Transport = ModbusTransportMode.RtuOverTcp })
.ShouldBeOfType<ModbusRtuOverTcpTransport>();
[Fact]
public void Default_closure_builds_tcp_transport_for_Tcp()
=> BuildDefaultTransport(new ModbusDriverOptions())
.ShouldBeOfType<ModbusTcpTransport>();
}
```
(If `_transportFactory` reflection proves brittle, assert instead that a `RtuOverTcp` driver initialised against an unreachable host degrades without ever constructing an MBAP frame — but the closure-reflection test is the tightest.)
**Step 2 — run & expect FAIL:**
`dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests --filter "FullyQualifiedName~ModbusTransportWiringTests"`
**Step 3 — minimal impl:** driver ctor default = `?? (o => ModbusTransportFactory.Create(o))`; probe: add `ModbusTransportMode Transport` to `ProbeTarget`, parse `dto.Transport` via `ParseEnum`, and build the probe transport through `ModbusTransportFactory.Create(new ModbusDriverOptions { Host, Port, Timeout, Transport, AutoReconnect = false })`.
**Step 4 — run & expect PASS** (+ run the full Modbus.Tests suite green).
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): route driver + probe transports through ModbusTransportFactory
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 8: AdminUI — `Transport` selector on `ModbusDriverForm`
**Classification:** small
**Estimated implement time:** ~5 min
**Parallelizable with:** Task 7
**Files:**
- Modify: `src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Components/Shared/Drivers/Forms/ModbusDriverForm.razor`
- Test: `tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/ModbusDriverFormModelTests.cs`
Add a `Transport` `<InputSelect>` to the **Protocol** panel (design's target `ModbusDriverPage.razor` is retired; `ModbusDriverForm.razor` is the live host — it serializes `ModbusDriverOptions` directly through `_jsonOpts`, which already carries `JsonStringEnumConverter`, so `Transport` emits as a name string automatically; `Transport` is **not** an endpoint key so it is not stripped by `GetConfigJson`). Add `public ModbusTransportMode Transport { get; set; } = ModbusTransportMode.Tcp;` to `FormModel`, map it in `FromOptions`/`ToOptions`. Host/Port stay on `ModbusDeviceForm` — a `RtuOverTcp` gateway uses the same `host:port` shape. Extend the existing `ModbusDriverFormModelTests` (round-trip + string-enum guard).
**Step 1 — failing test** (append to `ModbusDriverFormModelTests`):
```csharp
[Fact]
public void Round_trip_preserves_Transport_mode()
{
var form = new ModbusDriverForm.FormModel { Transport = ModbusTransportMode.RtuOverTcp };
var json = JsonSerializer.Serialize(form.ToOptions(), JsonOpts);
var back = ModbusDriverForm.FormModel.FromOptions(
JsonSerializer.Deserialize<ModbusDriverOptions>(json, JsonOpts)!);
back.Transport.ShouldBe(ModbusTransportMode.RtuOverTcp);
json.ShouldContain("\"transport\":\"RtuOverTcp\""); // name string, never a number
}
```
**Step 2 — run & expect FAIL:**
`dotnet test tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests --filter "FullyQualifiedName~ModbusDriverFormModelTests"`
**Step 3 — minimal impl:** add the `Transport` `FormModel` property + `FromOptions`/`ToOptions` mapping, and an `<InputSelect @bind-Value="_form.Transport" @bind-Value:after="EmitAsync">` looping `Enum.GetValues<ModbusTransportMode>()` in the Protocol panel, with a form-text hint: "RtuOverTcp = talk raw RTU frames to a serial→Ethernet gateway; must match the gateway's mode."
**Step 4 — run & expect PASS.** (AdminUI has no bUnit — the razor binding itself is proven live in Task 10; this model test is the reflection substitute per the AdminUI live-verify memory.)
**Step 5 — commit:**
`git commit -am "feat(modbus-rtu): add Transport selector to the AdminUI Modbus driver form
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 9: Docker `rtu_over_tcp` fixture + RTU-over-TCP integration test
**Classification:** standard (new component / multi-file)
**Estimated implement time:** ~5 min
**Parallelizable with:** none
**Files:**
- Create: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/profiles/rtu_over_tcp.json`
- Modify: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/docker-compose.yml`
- Create: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/ModbusRtuOverTcpFixture.cs`
- Create: `tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/ModbusRtuOverTcpTests.cs`
- Modify (only if the pymodbus RTU-framer confirmation fails): `Docker/Dockerfile` + `Docker/rtu_over_tcp_server.py`
**FIRST sub-step — confirm the unknown (design §8 #1):** verify the pymodbus simulator actually exposes the RTU framer on a TCP server. The checked-in `profiles/standard.json` already sets `server_list.srv.framer: "socket"`, so the knob exists; the RTU profile sets `"framer": "rtu"` (comm stays `"tcp"`). Bring it up and probe with the new driver:
```bash
lmxopcua-fix sync modbus
lmxopcua-fix up modbus rtu_over_tcp
# then run the integration test (below) against MODBUS_RTU_SIM_ENDPOINT=10.100.0.35:5021
```
If pymodbus 3.13's simulator does **not** honour `framer=rtu` on a TCP server (garbled/MBAP-framed replies), **fall back** to a stdlib `rtu_over_tcp_server.py` modelled on the existing `exception_injector.py` (same asyncio TCP-server shape, but frame with `[addr][PDU][CRC-16]` via a Python CRC-16/MODBUS instead of the MBAP header) + a `COPY rtu_over_tcp_server.py` line in the Dockerfile and a `command:` override on the service. Record which path was taken in the test-class summary.
Fixture details: bind host port **`5021`** (NOT the shared `:5020` — the `rtu_over_tcp` service must co-run with `standard` and sidestep the shared-port stale-container trap). Add `labels: { project: lmxopcua }` per the program fixture convention (existing services carry none — `lmxopcua-fix sync` normally owns the label host-side, but add it in-file for this service so it is discoverable). `ModbusRtuOverTcpFixture` mirrors `ModbusSimulatorFixture` but reads `MODBUS_RTU_SIM_ENDPOINT` (default `10.100.0.35:5021`) with the same skip-clean pattern.
**Step 1 — failing test** (`ModbusRtuOverTcpTests.cs` — read + write round-trip over RTU-over-TCP):
```csharp
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
[Collection(ModbusRtuOverTcpCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "RtuOverTcp")]
public sealed class ModbusRtuOverTcpTests(ModbusRtuOverTcpFixture sim)
{
[Fact]
public async Task Reads_a_seeded_holding_register_over_rtu_framing()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var opts = new ModbusDriverOptions
{
Host = sim.Host, Port = sim.Port, UnitId = 1,
Transport = ModbusTransportMode.RtuOverTcp,
Timeout = TimeSpan.FromSeconds(2),
Probe = new ModbusProbeOptions { Enabled = false },
RawTags = ModbusRawTags.Entries([
new ModbusTagDefinition("HR5", ModbusRegion.HoldingRegisters, Address: 5,
DataType: ModbusDataType.UInt16, Writable: false),
]),
};
await using var driver = new ModbusDriver(opts, "modbus-rtu-int");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["HR5"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u); // Good
results[0].Value.ShouldBe((ushort)5); // HR[5] seeded = address-as-value
}
[Fact]
public async Task Writes_and_reads_back_a_holding_register_over_rtu_framing()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var opts = new ModbusDriverOptions
{
Host = sim.Host, Port = sim.Port, UnitId = 1,
Transport = ModbusTransportMode.RtuOverTcp,
Timeout = TimeSpan.FromSeconds(2),
Probe = new ModbusProbeOptions { Enabled = false },
RawTags = ModbusRawTags.Entries([
new ModbusTagDefinition("HR200", ModbusRegion.HoldingRegisters, Address: 200,
DataType: ModbusDataType.UInt16, Writable: true),
]),
};
await using var driver = new ModbusDriver(opts, "modbus-rtu-int-w");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var writes = await driver.WriteAsync([new WriteRequest("HR200", (ushort)4242)],
TestContext.Current.CancellationToken);
writes[0].StatusCode.ShouldBe(0u);
var back = await driver.ReadAsync(["HR200"], TestContext.Current.CancellationToken);
back[0].Value.ShouldBe((ushort)4242);
}
}
```
(Seed `rtu_over_tcp.json` with the same `HR[0..31]=address-as-value` + `HR[200..209]=scratch` layout as `standard.json` so these addresses resolve.)
**Step 2 — run & expect FAIL / SKIP** without the fixture, then bring it up:
```bash
lmxopcua-fix sync modbus && lmxopcua-fix up modbus rtu_over_tcp
MODBUS_RTU_SIM_ENDPOINT=10.100.0.35:5021 dotnet test tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests --filter "FullyQualifiedName~ModbusRtuOverTcpTests"
```
**Step 3 — minimal impl:** the `rtu_over_tcp.json` profile + compose service (+ stdlib server fallback only if the framer confirmation failed) + the fixture class. Iterate until both facts hold on the wire.
**Step 4 — run & expect PASS** against the live fixture.
**Step 5 — commit:**
`git commit -am "test(modbus-rtu): add rtu_over_tcp pymodbus fixture + RTU-over-TCP integration tests
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Task 10: Live `/run` verification on docker-dev
**Classification:** standard (live gate)
**Estimated implement time:** ~5 min
**Parallelizable with:** none
**Files:**
- Modify (docs only): `docs/plans/2026-07-24-driver-expansion-tracking.md` (record Wave-1 Modbus-RTU live-gate result)
No new code — the live-verify discipline (program §3.1) proves the Razor binding + deploy path that unit tests can't. Against the local docker-dev rig (AdminUI `http://localhost:9200`, login disabled — drive it yourself; do not wait for the user to sign in):
1. Bring up the `rtu_over_tcp` fixture (`lmxopcua-fix up modbus rtu_over_tcp`, host `:5021`).
2. In `/raw`, author a Modbus device pointing Host/Port at the docker host `:5021`, and set the driver **Transport = RtuOverTcp** in the driver-config modal (the Task 8 selector). Run **Test Connect** — expect green (the probe now runs FC03 over RTU framing).
3. Author a holding-register raw tag (e.g. `HR5`), reference it into a UNS equipment, and deploy.
4. Read it back via Client.CLI against the local server, or the `/uns` value panel:
`dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=<RawPath-of-HR5>"`
— expect Good quality + the seeded value.
5. Write to a writable register (`HR200`) via Client.CLI `write` and confirm it round-trips.
6. Record PASS/FAIL + evidence in the tracking doc.
**Step 5 — commit:**
`git commit -am "docs(modbus-rtu): record Wave-1 RTU-over-TCP live /run gate result
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW"`
---
## Ordering summary
Framer/CRC unit layer (Tasks 02) → transport (Tasks 34) → factory + config + driver/probe wiring (Tasks 57) → AdminUI selector (Task 8) → docker integration fixture (Task 9) → live `/run` (Task 10). Tasks 1 & 3 can run alongside Task 0; Task 5 alongside Task 6; Task 7 alongside Task 8. Commit after every task. DRY: `ModbusRtuFraming` and `ModbusSocketLifecycle` are each written once and composed; no codec/planner/health code is touched. YAGNI: no direct-serial, no ASCII, no per-tag config, no `BuildSlaveHostName` change.