Files
lmxopcua/tests/Drivers
Joseph Doherty 74afc3f90a perf(historian): batch alarm-history writes; pipeline gateway SendEvent (lmxopcua#746)
All three alarm-history writers inserted one event per round trip, serially
(SqlServer also opened a pooled connection per event), so a 10000-event
alarm storm drained at 10000 x RTT while the backlog sat in LocalDb.

- Sql.Common.AlarmBatchWrite: one statement per chunk; a chunk that fails
  PermanentFail-class is re-sent event by event so only the poison event
  dead-letters; a transient failure retries the chunk; a cancellation never
  dead-letters.
- SqlServer: multi-row insert-if-absent over a VALUES set (150 events per
  statement, under the 2100-parameter limit), duplicate ids in a batch
  written once; a duplicate-key race isolates per event, where it is Ack.
  No new table type, so no schema migration (the review suggested a TVP;
  the VALUES form gets the same one-round-trip-per-chunk without one).
- QuestDb: multi-row INSERTs of 500 events; pre-1970 events still
  dead-letter unsent.
- Gateway: no batch RPC exists, so sends are pipelined, at most 8 in
  flight, outcomes kept in input order.

Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 15:40:46 -05:00
..