Joseph Doherty 4e80db4844 AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 04:24:40 -04:00

144 lines
7.6 KiB
C#
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip;
/// <summary>
/// AB CIP / EtherNet-IP driver configuration, bound from the driver's <c>DriverConfig</c>
/// JSON at <c>DriverHost.RegisterAsync</c>. One instance supports N devices (PLCs) behind
/// the same driver; per-device routing is keyed on <see cref="AbCipDeviceOptions.HostAddress"/>
/// via <c>IPerCallHostResolver</c>.
/// </summary>
/// <remarks>
/// Per v2 plan decisions #11 (libplctag), #41 (AbCip vs AbLegacy split), #143144 (per-call
/// host resolver + resilience keys), #144 (bulkhead keyed on <c>(DriverInstanceId, HostName)</c>).
/// </remarks>
public sealed class AbCipDriverOptions
{
/// <summary>
/// PLCs this driver instance talks to. Each device contributes its own <see cref="AbCipHostAddress"/>
/// string as the <c>hostName</c> key used by resilience pipelines and the Admin UI.
/// </summary>
public IReadOnlyList<AbCipDeviceOptions> Devices { get; init; } = [];
/// <summary>Pre-declared tag map across all devices — AB discovery lands in PR 5.</summary>
public IReadOnlyList<AbCipTagDefinition> Tags { get; init; } = [];
/// <summary>Per-device probe settings. Falls back to defaults when omitted.</summary>
public AbCipProbeOptions Probe { get; init; } = new();
/// <summary>
/// Default libplctag call timeout applied to reads/writes/discovery when the caller does
/// not pass a more specific value. Matches the Modbus driver's 2-second default.
/// </summary>
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
/// <summary>
/// When <c>true</c>, <c>DiscoverAsync</c> walks each device's Logix symbol table via
/// the <c>@tags</c> pseudo-tag + surfaces controller-resident globals under a
/// <c>Discovered/</c> sub-folder. Pre-declared tags always emit regardless. Default
/// <c>false</c> to keep the strict-config path for deployments where only declared tags
/// should appear in the address space.
/// </summary>
public bool EnableControllerBrowse { get; init; }
/// <summary>
/// Task #177 — when <c>true</c>, declared ALMD tags are surfaced as alarm conditions
/// via <see cref="Core.Abstractions.IAlarmSource"/>; the driver polls each subscribed
/// alarm's <c>InFaulted</c> + <c>Severity</c> members + fires <c>OnAlarmEvent</c> on
/// state transitions. Default <c>false</c> — operators explicitly opt in because
/// projection semantics don't exactly mirror Rockwell FT Alarm &amp; Events; shops
/// running FT Live should keep this off + take alarms through the native route.
/// </summary>
public bool EnableAlarmProjection { get; init; }
/// <summary>
/// Poll interval for the ALMD projection loop. Shorter intervals catch faster edges
/// at the cost of PLC round-trips; edges shorter than this interval are invisible to
/// the projection (a 0→1→0 transition within one tick collapses to no event). Default
/// 1 second — matches typical SCADA alarm-refresh conventions.
/// </summary>
public TimeSpan AlarmPollInterval { get; init; } = TimeSpan.FromSeconds(1);
}
/// <summary>
/// One PLC endpoint. <see cref="HostAddress"/> must parse via
/// <see cref="AbCipHostAddress.TryParse"/>; misconfigured devices fail driver
/// initialization rather than silently connecting to nothing.
/// </summary>
/// <param name="HostAddress">Canonical <c>ab://gateway[:port]/cip-path</c> string.</param>
/// <param name="PlcFamily">Which per-family profile to apply. Determines ConnectionSize,
/// request-packing support, unconnected-only hint, and other quirks.</param>
/// <param name="DeviceName">Optional display label for Admin UI. Falls back to <see cref="HostAddress"/>.</param>
public sealed record AbCipDeviceOptions(
string HostAddress,
AbCipPlcFamily PlcFamily = AbCipPlcFamily.ControlLogix,
string? DeviceName = null);
/// <summary>
/// One AB-backed OPC UA variable. Mirrors the <c>ModbusTagDefinition</c> shape.
/// </summary>
/// <param name="Name">Tag name; becomes the OPC UA browse name and full reference.</param>
/// <param name="DeviceHostAddress">Which device (<see cref="AbCipDeviceOptions.HostAddress"/>) this tag lives on.</param>
/// <param name="TagPath">Logix symbolic path (controller or program scope).</param>
/// <param name="DataType">Logix atomic type, or <see cref="AbCipDataType.Structure"/> for UDT-typed tags.</param>
/// <param name="Writable">When <c>true</c> and the tag's ExternalAccess permits writes, IWritable routes writes here.</param>
/// <param name="WriteIdempotent">Per plan decisions #44#45, #143 — safe to replay on write timeout. Default <c>false</c>.</param>
/// <param name="Members">For <see cref="AbCipDataType.Structure"/>-typed tags, the declared UDT
/// member layout. When supplied, discovery fans out the UDT into a folder + one Variable per
/// member (member TagPath = <c>{tag.TagPath}.{member.Name}</c>). When <c>null</c> on a Structure
/// tag, the driver treats it as a black-box and relies on downstream configuration to address
/// members individually via dotted <see cref="AbCipTagPath"/> syntax. Ignored for atomic types.</param>
/// <param name="SafetyTag">GuardLogix safety-partition tag hint. When <c>true</c>, the driver
/// forces <c>SecurityClassification.ViewOnly</c> on discovery regardless of
/// <paramref name="Writable"/> — safety tags can only be written from the safety task of a
/// GuardLogix controller; non-safety writes violate the safety-partition isolation and are
/// rejected by the PLC anyway. Surfaces the intent explicitly instead of relying on the
/// write attempt failing at runtime.</param>
public sealed record AbCipTagDefinition(
string Name,
string DeviceHostAddress,
string TagPath,
AbCipDataType DataType,
bool Writable = true,
bool WriteIdempotent = false,
IReadOnlyList<AbCipStructureMember>? Members = null,
bool SafetyTag = false);
/// <summary>
/// One declared member of a UDT tag. Name is the member identifier on the PLC (e.g. <c>Speed</c>,
/// <c>Status</c>), DataType is the atomic Logix type, Writable/WriteIdempotent mirror
/// <see cref="AbCipTagDefinition"/>. Declaration-driven — the real CIP Template Object reader
/// (class 0x6C) that would auto-discover member layouts lands as a follow-up PR.
/// </summary>
public sealed record AbCipStructureMember(
string Name,
AbCipDataType DataType,
bool Writable = true,
bool WriteIdempotent = false);
/// <summary>Which AB PLC family the device is — selects the profile applied to connection params.</summary>
public enum AbCipPlcFamily
{
ControlLogix,
CompactLogix,
Micro800,
GuardLogix,
}
/// <summary>
/// Background connectivity-probe settings. Enabled by default; the probe reads a cheap tag
/// on the PLC at the configured interval to drive <see cref="Core.Abstractions.IHostConnectivityProbe"/>
/// state transitions + Admin UI health status.
/// </summary>
public sealed class AbCipProbeOptions
{
public bool Enabled { get; init; } = true;
public TimeSpan Interval { get; init; } = TimeSpan.FromSeconds(5);
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
/// <summary>
/// Tag path used for the probe. If null, the driver attempts to read a default
/// system tag (PR 8 wires this up — the choice is family-dependent, e.g.
/// <c>@raw_cpu_type</c> on ControlLogix or a user-configured probe tag on Micro800).
/// </summary>
public string? ProbeTagPath { get; init; }
}