Joseph Doherty
|
4e80db4844
|
AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
2026-04-20 04:24:40 -04:00 |
|
Joseph Doherty
|
088c4817fe
|
AB CIP @tags walker — CIP Symbol Object decoder + LibplctagTagEnumerator. Closes task #178. CipSymbolObjectDecoder (pure-managed, no libplctag dep) parses the raw Symbol Object (class 0x6B) blob returned by reading the @tags pseudo-tag into an enumerable sequence of AbCipDiscoveredTag records. Entry layout per Rockwell CIP Vol 1 + Logix 5000 CIP Programming Manual 1756-PM019, cross-checked against libplctag's ab/cip.c handle_listed_tags_reply — u32 instance-id + u16 symbol-type + u16 element-length + 3×u32 array-dims + u16 name-length + name[len] + even-pad. Symbol-type lower 12 bits carry the CIP type code (0xC1 BOOL, 0xC2 SINT, …, 0xD0 STRING), bit 12 is the system-tag flag, bit 15 is the struct flag (when set lower 12 bits become the template instance id). Truncated tails stop decoding gracefully — caller keeps whatever parsed cleanly rather than getting an exception mid-walk. Program:-scope names (Program:MainProgram.StepIndex) are split via SplitProgramScope so the enumerator surfaces scope + simple name separately. 12 atomic type codes mapped (BOOL/SINT/INT/DINT/LINT/USINT/UINT/UDINT/ULINT/REAL/LREAL/STRING + DT/DATE_AND_TIME under Dt); unknown codes return null so the caller treats them as opaque Structure. LibplctagTagEnumerator is the real production walker — creates a libplctag Tag with name=@tags against the device's gateway/port/path, InitializeAsync + ReadAsync + GetBuffer, hands bytes to the decoder. Factory LibplctagTagEnumeratorFactory replaces EmptyAbCipTagEnumeratorFactory as the AbCipDriver default. AbCipDriverOptions gains EnableControllerBrowse (default false) matching the TwinCAT pattern — keeps the strict-config path for deployments where only declared tags should appear. When true, DiscoverAsync walks each device's @tags + emits surviving symbols under Discovered/ sub-folder. System-tag filter (AbCipSystemTagFilter shipped in PR 5) runs alongside the wire-layer system-flag hint. Tests — 18 new CipSymbolObjectDecoderTests with crafted byte arrays matching the documented layout — single-entry DInt, theory across 12 atomic type codes, unknown→null, struct flag override, system flag surface, Program:-scope split, multi-entry wire-order with even-pad, truncated-buffer graceful stop, empty buffer, SplitProgramScope theory across 6 shapes. 4 pre-existing AbCipDriverDiscoveryTests that tested controller-enumeration behavior updated with EnableControllerBrowse=true so they continue exercising the walker path (behavior unchanged from their perspective). Total AbCip unit tests now 192/192 passing (+26 from the RMW merge's 166); full solution builds 0 errors; other drivers untouched. Field validation note — the decoder layout matches published Rockwell docs + libplctag C source, but actual @tags responses vary slightly by controller firmware (some ship an older entry format with u16 array dims instead of u32). Any layout drift surfaces as gibberish names in the Discovered/ folder; field testing will flag that for a decoder patch if it occurs.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
2026-04-19 21:13:20 -04:00 |
|
Joseph Doherty
|
60b8d6f2d0
|
AB CIP PR 9-12 — Per-PLC-family profile tests + GuardLogix safety-tag support. Consolidates PRs 9/10/11/12 from the plan (ControlLogix / CompactLogix / Micro800 / GuardLogix integration suites) into a single PR because the per-family work that actually ships without a live ab_server binary is profile-metadata assertion + unit-level driver-option binding. Per-family integration tests that require a running simulator are deferred to the ab_server-CI follow-up already tracked from PR 3 (download prebuilt Windows binary as GitHub release asset). ControlLogix — baseline profile asserted (controllogix attribute, 4002 LFO ConnectionSize, 1,0 default path, request-packing + connected-messaging, 4000B max fragment). CompactLogix — narrower 504 ConnectionSize for 5069-L3x safety, 500B max fragment, lib attribute compactlogix which libplctag maps to the ControlLogix family internally but via our profile chain we surface it as a distinct knob so future quirk handling (5069 narrow-window regression cases) hangs off the compactlogix attribute. Micro800 — empty CIP path for no-backplane routing, 488B ConnectionSize, 484B fragment cap, request packing + connected messaging both disabled (most models reject Forward_Open), micro800 lib attribute. Test asserts the driver correctly parses an ab://192.168.1.20/ host address with empty path + forwards the empty path through AbCipTagCreateParams so libplctag sees the unconnected-only configuration. GuardLogix — wire protocol identical to ControlLogix (safety partition is a per-tag concern, not a wire-layer distinction) so profile defaults match ControlLogix. New AbCipTagDefinition.SafetyTag field — when true, the driver forces SecurityClassification.ViewOnly in discovery regardless of the Writable flag, and IWritable rejects the write upfront with BadNotWritable. Matches the Rockwell safety-partition isolation model where non-safety-task writes to safety tags would be rejected by the PLC anyway — surfacing the intent at the driver surface prevents wasted wire round-trips + gives Admin UI users a correct ViewOnly rendering. 14 new unit tests in AbCipPlcFamilyTests covering — ControlLogix profile defaults + correct profile selection at Initialize, CompactLogix narrower-than-ControlLogix ConnectionSize + fragment cap, Micro800 empty path parses + SupportsConnectedMessaging=false + SupportsRequestPacking=false + read forwards empty path + micro800 attribute through to libplctag, GuardLogix wire-protocol parity with ControlLogix, GuardLogix safety tag surfaces as ViewOnly in discovery even when Writable=true, GuardLogix safety-tag write rejected with BadNotWritable even when Writable=true, ForFamily theory (4 families → correct libplctag attribute). Total AbCip unit tests now 161/161 passing (+14 from PR 8's 147). Modbus + other drivers untouched; full solution builds 0 errors. PR 13 (IAlarmSource via tag-projected ALMA/ALMD blocks) remains deferred per the plan — feature-flagged pattern not needed before go-live.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
2026-04-19 17:18:51 -04:00 |
|
Joseph Doherty
|
b06a1ba607
|
AB CIP PR 6 — UDT member-declaration support. Declaration-driven UDT member fan-out — users declare a UDT-typed tag once with an explicit Members list and the driver (1) expands member-addressable tags synthetically at Initialize time so Read/Write/Subscribe hit individual native tags per member, (2) emits a folder + one Variable per member in DiscoverAsync instead of a single opaque Structure Variable. Matches the Logix 5000 addressing convention where members are reached via dotted syntax (Motor1.Speed, Motor1.Running) — AbCipTagPath already parsed this shape in PR 2, so PR 6 just had to wire config→TagPath composition. New AbCipStructureMember record — Name / DataType / Writable / WriteIdempotent — plus optional Members list on AbCipTagDefinition that's ignored for atomic types and optional for Structure types. When Structure has null or empty Members the driver falls back to emitting a single opaque Variable so downstream config can address members manually (the "black box" path documented in AbCipTagDefinition's docstring). AbCipDriver.InitializeAsync now iterates tags + for every Structure tag with non-empty Members synthesises a child AbCipTagDefinition per member (composed full-reference Parent.Member + composed TagPath parent.member passed through to libplctag as a normal symbolic read). Per-member Writable/WriteIdempotent metadata propagates so IWritable correctly rejects writes to members flagged non-writable even when the parent tag is writable — each member stands alone from the resilience + authz perspective. DiscoverAsync gains a matching branch — Structure with Members emits an intermediate folder named after the parent tag + one Variable per member under it (browse name = member.Name, FullName = Parent.Member). Members with Writable=false surface SecurityClassification.ViewOnly, WriteIdempotent flag passes through to the DriverAttributeInfo. Structure without Members falls through to the normal single-Variable path. Whole-UDT read optimization (one libplctag call returns the packed buffer + client-side member decode) is deferred — needs the CIP Template Object class 0x6C reader which is blocked on the same libplctag 1.5.2 TagInfoPlcMapper gap that deferred the real @tags walker in PR 5. AbCipTemplateCache shipped in PR 5 is the drop-in point when that reader lands. Per-member reads today are N native round-trips; whole-UDT optimisation is a perf win, not a correctness gap. 7 new unit tests in AbCipUdtMemberTests — UDT fan-out to Variable children under folder with correct SecurityClassification + WriteIdempotent propagation, member reads via synthesised full-reference with correct per-member values, member writes routing to correct TagPath, member Writable=false flag correctly blocking IWritable, Structure without Members falls back to single Variable, empty Members list treated identically to null, UDT tags coexist with flat tags in the discovery output. Total AbCip unit tests now 130/130 passing (+7 from PR 5's 123). Modbus + other drivers untouched; full solution builds 0 errors. Unblocks PR 7 (ISubscribable) — the poll engine already works with member-level full references.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
2026-04-19 17:09:06 -04:00 |
|
Joseph Doherty
|
3e0452e8a4
|
AB CIP PR 2 — scaffolding + Core (AbCipDriver skeleton + libplctag binding + host / tag-path / data-type / status-code parsers + per-family profiles + SafeHandle wrapper + test harness). Ships everything needed to stand up the driver project as a compiling assembly with no wire calls yet — PR 3 adds IReadable against ab_server which is the first PR that actually touches the native library. Project reference shape matches Modbus / OpcUaClient / S7 (only Core.Abstractions, no Core / Configuration / Polly) so the driver stays lean and doesn't drag EF Core into every deployment that wants AB support. libplctag 1.5.2 pinned (1.6.x only exists as alpha — stable 1.5 series covers ControlLogix / CompactLogix / Micro800 / SLC500 / PLC-5 / MicroLogix which matches plan decision #11 family coverage). libplctag.NativeImport arrives transitively. AbCipHostAddress parses ab://gateway[:port]/cip-path canonical strings end-to-end: handles hostname or IP gateway, optional explicit port (default 44818 EtherNet-IP reserved), CIP path including bridged routes (1,2,2,10.0.0.10,1,0), empty path for Micro800 / MicroLogix without backplane routing, case-insensitive scheme, default-port stripping in canonical form for round-trip stability. Opaque string survives straight into libplctag's gateway / path attributes so no translation layer at wire time. AbCipTagPath handles the full Logix symbolic tag surface — controller-scope (Motor1_Speed), program-scope (Program:MainProgram.StepIndex), structured member access (Motor1.Speed.Setpoint), multi-dim array subscripts (Matrix[1,2,3]), bit-within-DINT via .N syntax (Flags.3, Motor.Status.12) with valid range 0-31 per Logix 5000 General Instructions Reference. Structural capture so PR 6 UDT work can walk the path against a cached template without reparsing. Rejects malformed shapes (empty scopes, ident starting with digit, spaces, empty/negative/non-numeric subscripts, unbalanced brackets, leading / trailing dots). Round-trips via ToLibplctagName producing the exact string libplctag's name attribute expects. AbCipDataType mirrors ModbusDataType shape — atomic Bool / SInt / Int / DInt / LInt / USInt / UInt / UDInt / ULInt / Real / LReal / String / Dt plus a Structure marker for UDT-typed tags (resolved via CIP Template Object at discovery time in PR 5/6). ToDriverDataType adapter follows the Modbus widening convention for unsigned + 64-bit until DriverDataType picks those up. AbCipStatusMapper covers the CIP general-status values an AB PLC actually returns during normal operation (0x00/0x04/0x05/0x06/0x08/0x0A/0x0B/0x0E/0x10/0x13/0x16) + libplctag PLCTAG_STATUS_* codes (0, >0 pending, negative error families). Mirrors ModbusDriver.MapModbusExceptionToStatus so Admin UI status displays stay uniform across drivers. PlcTagHandle is a SafeHandle around the int32 native tag ID with plc_tag_destroy slot wired as a no-op for PR 2 (P/Invoke DllImport arrives with PR 3 when the wire calls land). Lifetime guaranteed by the SafeHandle finalizer — every leaked handle gets cleaned up even when the owner is GC'd without explicit Dispose. IsInvalid when native ID <= 0 so destroying a negative (error) handle never happens. Critical because driver-specs.md §3 flags libplctag native heap as invisible to GetMemoryFootprint — leaked handles directly feed the Tier-B recycle trigger. AbCipDriverOptions captures the multi-device shape — one driver instance can talk to N PLCs via Devices[] (each with HostAddress + PlcFamily + optional DeviceName); Tags[] references devices by HostAddress as the cross-key; AbCipProbeOptions + driver-wide Timeout. AbCipDriver implements IDriver only — InitializeAsync parses every device's HostAddress and selects its PlcFamilyProfile (fails fast on malformed strings via InvalidOperationException → Faulted health), per-device state cached in a DeviceState record with parsed address + profile + empty TagHandles dict for later PRs. ReinitializeAsync is the Tier-B escape hatch — shuts down every device, disposes every PlcTagHandle via SafeHandle lifetime, reinitializes from options. ShutdownAsync clears the device dict and flips health to Unknown. PlcFamilies/AbCipPlcFamilyProfile gives four baseline profiles — ControlLogix (4002 ConnectionSize, path 1,0, Large Forward Open + request packing + connected messaging, FW20+ baseline), CompactLogix (narrower 504 default for 5069-L3x safety), Micro800 (488 cap, empty path, unconnected-only, no request packing), GuardLogix (shares ControlLogix wire protocol — safety partition is tag-level, surfaced as ViewOnly in PR 12). Tests — 76 new cases across 4 test classes — AbCipHostAddressTests (10 valid shapes, 10 invalid shapes, ToString canonicalization, round-trip stability), AbCipTagPathTests (18 cases including multi-scope / multi-member / multi-subscript / bit-in-DINT / rejected shapes / underscore idents / round-trip), AbCipStatusMapperTests (12 CIP + 8 libplctag codes), AbCipDriverTests (IDriver lifecycle + multi-device init + malformed-address fault + per-family profile lookup + PlcTagHandle invalid/dispose idempotency + AbCipDataType mapping). Full solution builds 0 errors; 254 warnings are pre-existing xUnit1051 CancellationToken hints outside this PR. Solution file updated to include both new projects. Unblocks PR 3 (IReadable against ab_server) which is the first PR to exercise the native library end-to-end.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
2026-04-19 15:58:15 -04:00 |
|