Files
lmxopcua/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport/AbTransportException.cs
T
Joseph Doherty 7892eb13a8 fix(abcip): harden Ab.Transport CIP codec and EncapsulationClient (#564, #565)
CIP codec (#564): PatchU16 bounds guard; CipReply content equality; CipPath
port/length/ASCII/odd/oversize validation with ArgumentException for malformed
tag names and routes; CipPath.MessageRouter/ConnectionManager are now
ReadOnlySpan<byte>; refused Forward Open surfaces ForwardOpenRefusedException
with structured general/extended status; test CaptureFile uses BinaryPrimitives.

EncapsulationClient (#565): frame write bounded by the exchange timeout, which
faults (never cancels) the connection; finite positive timeouts enforced at
every entry point; gate wait bounded by the timeout; deterministic reorder of
the 300 ms test; new dispose-during-drain, gate-wait and RegisterSession
zero-context tests.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 22:54:32 -04:00

10 lines
425 B
C#

namespace ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport;
/// <summary>Thrown by both AB transports. <see cref="Status"/> drives OPC UA status mapping and the
/// driver's "controller answered, don't throttle the device" classification (05/STAB-8).</summary>
public class AbTransportException(AbStatus status, string message, Exception? inner = null)
: Exception(message, inner)
{
public AbStatus Status { get; } = status;
}