Joseph Doherty 5a9c4591b9 fix(cli-common): name native-driver-emitted status codes in SnapshotFormatter
Driver.FOCAS.Cli-005 follow-up: extend the SnapshotFormatter.FormatStatus
shortlist with the five Bad* codes the native-protocol mappers (FOCAS,
AbCip, AbLegacy) emit but which the shortlist previously left unnamed,
so they rendered only as severity-class 'Bad' instead of the documented
'BadDeviceFailure' / 'BadNotWritable' / ... names operators are told to
read off probe/write output.

Added entries:
  0x80020000 BadInternalError
  0x803B0000 BadNotWritable
  0x803C0000 BadOutOfRange
  0x803D0000 BadNotSupported
  0x80550000 BadDeviceFailure

(BadTimeout 0x800A0000 was already added under Driver.Cli.Common-001.)

Tests: SnapshotFormatterTests gains a new [Theory]
FormatStatus_names_native_driver_emitted_codes covering the five names,
and the existing well-known [Theory] is extended with the same entries
to enforce exact '0x... (Name)' rendering. Suite now 47 green (was 42).

Flips Driver.FOCAS.Cli-005 from Deferred to Resolved; README regenerated.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 15:14:08 -04:00

232 lines
12 KiB
Markdown

# Code Review — Driver.FOCAS.Cli
| Field | Value |
|---|---|
| Module | `src/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli` |
| Reviewer | Claude Code |
| Review date | 2026-05-22 |
| Commit reviewed | `76d35d1` |
| Status | Reviewed |
| Open findings | 0 |
## Checklist coverage
A comprehensive review completes every category, recording "No issues found" where
a category produced nothing rather than leaving it blank.
| # | Category | Result |
|---|---|---|
| 1 | Correctness & logic bugs | Driver.FOCAS.Cli-001 |
| 2 | OtOpcUa conventions | No issues found |
| 3 | Concurrency & thread safety | Driver.FOCAS.Cli-002 |
| 4 | Error handling & resilience | Driver.FOCAS.Cli-001, Driver.FOCAS.Cli-003 |
| 5 | Security | No issues found |
| 6 | Performance & resource management | Driver.FOCAS.Cli-004 |
| 7 | Design-document adherence | Driver.FOCAS.Cli-005 |
| 8 | Code organization & conventions | No issues found |
| 9 | Testing coverage | No issues found (see note) |
| 10 | Documentation & comments | No issues found |
> Category 9 note: per `docs/DriverClis.md` the FOCAS CLI deliberately ships
> with no CLI-level test project (hardware-gated, followed the Tier-C isolation
> work on task #220). The four command classes are thin pass-throughs to the
> already-tested `FocasDriver`; the only CLI-local logic is `ParseValue` /
> `ParseBool` / `SynthesiseTagName`, which the sibling CLIs cover with unit
> tests. The absence of a `*.Cli.Tests` project is an intentional, documented
> gap rather than a review finding — but see Driver.FOCAS.Cli-001 for the parse
> path that would benefit most from coverage.
## Findings
### Driver.FOCAS.Cli-001
| Field | Value |
|---|---|
| Severity | Low |
| Category | Error handling & resilience |
| Location | `Commands/WriteCommand.cs:58-68` |
| Status | Resolved |
**Description:** `WriteCommand.ParseValue` parses the numeric `--value` types
(`Byte`/`Int16`/`Int32`/`Float32`/`Float64`) with `sbyte.Parse` / `short.Parse`
/ etc. These throw raw `FormatException` or `OverflowException` for malformed or
out-of-range input. Only the `Bit` case and the unsupported-type case throw
`CliFx.Exceptions.CommandException`. CliFx renders a `CommandException` as a
clean one-line error, but an uncaught `FormatException`/`OverflowException`
surfaces as a full .NET stack trace — a poor experience for an operator who
simply mistyped a value (e.g. `write -a R100 -t Int16 -v abc`). The parse
failure occurs before any driver work, so the redundant stack trace also
obscures that the write never reached the CNC.
**Recommendation:** Wrap the numeric parses (e.g. via `TryParse` per type, or a
`try`/`catch` that rethrows as `CommandException`) so malformed `--value` input
produces a clean, actionable message naming the expected type and the rejected
literal — consistent with how `ParseBool` already handles bad boolean input.
The same pattern exists in the sibling S7 CLI; a shared helper in
`Driver.Cli.Common` would fix both.
**Resolution:** Resolved 2026-05-23 — wrapped the `ParseValue` numeric switch in
`try/catch (FormatException)` and `try/catch (OverflowException)` that rethrow as
`CliFx.Exceptions.CommandException` with a message naming the `--type` and the
offending value, mirroring the friendly text the `Bit` path already produced.
Added `WriteCommandParseValueTests` with [Theory] cases covering non-numeric
input across `Byte`/`Int16`/`Int32`/`Float32`/`Float64`, overflow edges
(sbyte ±1, short max+1, > int.MaxValue), and an assertion that the exception
message names both the type and the offending value. A shared `Driver.Cli.Common`
helper is the cleaner long-term fix (cross-CLI duplication remains) but is left
to the Driver.Cli.Common review per this module's edit scope.
### Driver.FOCAS.Cli-002
| Field | Value |
|---|---|
| Severity | Low |
| Category | Concurrency & thread safety |
| Location | `Commands/SubscribeCommand.cs:45-51` |
| Status | Resolved |
**Description:** The `subscribe` command attaches an `OnDataChange` handler that
calls the synchronous `console.Output.WriteLine`. `OnDataChange` is raised from
the driver's `PollGroupEngine` tick thread, while the command's main flow writes
the "Subscribed to ..." banner from the CliFx invocation thread. The CliFx
`IConsole.Output` `TextWriter` is not documented as thread-safe; with a single
poll group the change events are serialised, but the banner write at line 55-56
can interleave with the first poll-driven change line. The handler is also never
detached from the event before driver disposal — benign here because the driver
is disposed in the same `finally`, but it leaves a dangling subscription if the
command is ever refactored to reuse the driver.
**Recommendation:** Write the "Subscribed" banner before wiring the
`OnDataChange` handler (it is informational and ordering-sensitive), or guard
console writes with a lock shared between the banner and the handler. Optionally
detach the handler in the `finally` block before `ShutdownAsync` for symmetry
with the `handle` teardown already present there.
**Resolution:** Resolved 2026-05-23 — introduced a `writeLock` shared between the
`OnDataChange` handler and the banner write so the poll-engine background thread
and the CliFx invocation thread can't interleave partial lines. Added an
explanatory comment above the handler explaining the CliFx-`IConsole` rationale
and the synchronous-on-background-thread design — mirroring the Modbus / S7
copies of this command. Also added a try/catch around the handler body so a
transient stdout error cannot tear down the poll loop, and Serilog-warn-logs the
swallowed exception. Added `SubscribeCommandConsoleHandlerTests` to guard the
`writeLock` + CliFx-`IConsole` rationale against future copy-paste regressions.
### Driver.FOCAS.Cli-003
| Field | Value |
|---|---|
| Severity | Low |
| Category | Error handling & resilience |
| Location | `FocasCommandBase.cs:19` (`CncPort`), `FocasCommandBase.cs:27` (`TimeoutMs`), `Commands/SubscribeCommand.cs:23` (`IntervalMs`) |
| Status | Resolved |
**Description:** The numeric command options `--cnc-port`, `--timeout-ms`, and
`--interval-ms` are accepted without range validation. A zero or negative
`--cnc-port` produces an invalid `focas://host:<n>` string; `--timeout-ms 0`
yields a zero `TimeSpan` operation timeout; a zero/negative `--interval-ms`
produces a non-positive `publishingInterval` passed straight into
`PollGroupEngine.Subscribe`. Depending on the engine tolerance these surface
either as an opaque downstream exception or as a tight-spinning poll loop rather
than a clear "value must be positive" message at the CLI boundary.
**Recommendation:** Validate the three numeric options at the top of
`ExecuteAsync` (or in `FocasCommandBase`) and throw a
`CliFx.Exceptions.CommandException` when out of range — port in `1..65535`,
timeout and interval strictly positive. The same gap exists across the sibling
driver CLIs, so a shared validation helper in `Driver.Cli.Common` is the
cleaner fix.
**Resolution:** Resolved 2026-05-23 — added a protected `ValidateOptions(int?
intervalMs = null)` helper on `FocasCommandBase` that rejects `--cnc-port`
outside `1..65535`, non-positive `--timeout-ms`, and non-positive
`--interval-ms` (when the caller passes one) with a `CliFx.Exceptions.CommandException`
naming the option and the rejected value. `ProbeCommand` / `ReadCommand` /
`WriteCommand` call `ValidateOptions()` without an interval, `SubscribeCommand`
calls `ValidateOptions(IntervalMs)`. Added `FocasCommandBaseValidationTests`
covering accept-defaults, reject out-of-range port (0, -1, 65536), reject
non-positive timeout / interval, and skip-interval-when-omitted. A shared
helper in `Driver.Cli.Common` is the cleaner cross-CLI fix and is recorded
against that module's review.
### Driver.FOCAS.Cli-004
| Field | Value |
|---|---|
| Severity | Low |
| Category | Performance & resource management |
| Location | `Commands/ProbeCommand.cs:37,54`; `Commands/ReadCommand.cs:37,46`; `Commands/WriteCommand.cs:45,54`; `Commands/SubscribeCommand.cs:39,73` |
| Status | Resolved |
**Description:** Every command declares `await using var driver = new FocasDriver(...)`
**and** explicitly calls `await driver.ShutdownAsync(CancellationToken.None)` in
the `finally` block. `FocasDriver.DisposeAsync()` itself calls `ShutdownAsync`,
so shutdown runs twice per command invocation. `FocasDriver.ShutdownAsync` is
idempotent (it clears `_devices` / `_tagsByName`, and the second pass iterates
an empty collection), so there is no functional bug — but the redundant call is
dead weight and obscures intent: a reader cannot tell whether the explicit
`ShutdownAsync` or the `await using` is the real teardown.
**Recommendation:** Drop the explicit `ShutdownAsync` from the `finally` blocks
and rely on `await using` for disposal, or drop `await using` and keep the
explicit teardown — but not both. The same redundancy exists in the sibling CLIs.
**Resolution:** Resolved 2026-05-23 — dropped the explicit
`await driver.ShutdownAsync(CancellationToken.None)` calls from the `finally`
blocks of `ProbeCommand`, `ReadCommand`, `WriteCommand`, and `SubscribeCommand`;
`await using` is now the sole driver-disposal mechanism per command
(`FocasDriver.DisposeAsync` itself runs `ShutdownAsync`). The subscribe command
keeps `UnsubscribeAsync` in its finally because that is a subscription-lifecycle
concern, not driver disposal. Added `CommandDisposalConventionsTests` to guard
the source-level convention against regression.
### Driver.FOCAS.Cli-005
| Field | Value |
|---|---|
| Severity | Low |
| Category | Design-document adherence |
| Location | `Commands/WriteCommand.cs:50`, `Commands/ProbeCommand.cs:50` (via `SnapshotFormatter.FormatStatus`) |
| Status | Resolved |
**Description:** `docs/Driver.FOCAS.Cli.md` documents `BadDeviceFailure` and
`BadCommunicationError` as the key diagnostic signals an operator reads off
`probe` / `write` output ("A `BadCommunicationError` means ... `BadDeviceFailure`
after a successful connect means ..."). The FOCAS driver `FocasStatusMapper`
also emits `BadNotWritable` (0x803B0000), `BadOutOfRange` (0x803C0000),
`BadNotSupported` (0x803D0000), `BadDeviceFailure` (0x80550000),
`BadInternalError` (0x80020000), and `BadTimeout` (0x800A0000). The shared
`SnapshotFormatter.FormatStatus` shortlist only names `Good`, `Bad`,
`BadCommunicationError`, `BadTimeout` (0x80060000 — note this is a *different*
code than the mapper `BadTimeout` 0x800A0000), `BadNoCommunication`,
`BadWaitingForInitialData`, `BadNodeIdUnknown`, `BadNodeIdInvalid`,
`BadTypeMismatch`, and `Uncertain`. Consequently a FOCAS `write` to a
non-writable address, a parameter-write rejected by the CNC, or a
`BadDeviceFailure` session-setup rejection renders as a bare hex code
(`0x803B0000`, `0x80550000`, …) with no name — directly contradicting the
documented workflow where the operator is told to read those status names.
**Recommendation:** Extend `SnapshotFormatter.FormatStatus` (in
`Driver.Cli.Common`) to name the `Bad*` codes the native-protocol drivers
actually emit — at minimum `BadNotWritable`, `BadOutOfRange`, `BadNotSupported`,
`BadDeviceFailure`, `BadInternalError`, and the mapper `BadTimeout`
(0x800A0000). The fix belongs in the shared library, but it is recorded here
because the gap defeats this module documented `probe`/`write` diagnostic
workflow; cross-reference the `Driver.Cli.Common` review.
**Resolution:** Resolved 2026-05-23 — the cross-CLI fix landed in `Driver.Cli.Common`:
`SnapshotFormatter.FormatStatus` now names `BadInternalError` (0x80020000),
`BadNotWritable` (0x803B0000), `BadOutOfRange` (0x803C0000), `BadNotSupported`
(0x803D0000), and `BadDeviceFailure` (0x80550000) — the five codes the FOCAS /
AbCip / AbLegacy native-protocol mappers all emit but the shortlist previously
left unnamed (the canonical `BadTimeout` 0x800A0000 was already added under
Driver.Cli.Common-001). FOCAS `probe` / `write` against a non-writable parameter,
out-of-range address, unsupported function, busy device, or CNC-handle failure
now renders with the named status the `docs/Driver.FOCAS.Cli.md` workflow
promises, restoring parity between the docs and the shipped behaviour. Regression
`[Theory]` `FormatStatus_names_native_driver_emitted_codes` added to
`SnapshotFormatterTests` so the five names can't silently drop out of the
shortlist again; the existing well-known shortlist `[Theory]` was extended with
the same five entries to enforce the exact `0x... (Name)` rendering. Suite now
47 green (was 42).