Files
lmxopcua/docs/plans
Joseph Doherty 6e9e4fa5ab docs: live-gate round two — truncation note + central proto path both proven (#541)
25 unmappable tags on SITE-A's sa-modbus2 closed both gaps in one setup: chip
25/26 SKIPPED, sample capped at exactly MaxSample=20, tooltip '(+5 more not
shown)'. Trimming to 20 skipped gave 20/21 with NO truncation note, pinning
the off-by-one boundary.

SITE-A is the discriminator for the proto path. Phase 6 partitioned it into
its own Akka mesh -- central's MEMBERS panel lists only central-1/central-2,
and DistributedPubSub does not federate across meshes. The single site-a
reference in central's log is the ClusterClient receptionist, a
point-to-point command path, not gossip. So the report's only route to the
page is TelemetryProtoMapNode -> gRPC -> TelemetryProtoMapCentral, and
central's view tracking a change made solely on the site node is conclusive.

Also corrects round one's claim that the fused central pair meant telemetry
never crossed gRPC -- wrong about this rig. All six ClusterNode rows carry
GrpcPort 4056 and Telemetry__Mode=Grpc; the two 'Telemetry stream to node'
lines that suggested a two-node dial set were startup failure warnings.

Rig restored: test tags deleted, SITE-A redeployed, sa-modbus2 back to 1 tag.
2026-08-06 02:12:44 -04:00
..