Joseph Doherty e08855fb9d
v2-ci / build (push) Successful in 4m52s
v2-ci / unit-tests (push) Failing after 15m58s
docs: source-verified deferment register + correct 17 drifted docs
Adds deferment.md — a source-verified inventory of new-driver status, all 17
open issues, in-code deferrals, open live gates and plan bookkeeping. Every
claim was checked against src/ and git, not against documentation.

Headline finding: three subsystems are authored, persisted and shipped but
never executed —
  * Node ACLs: IPermissionEvaluator/TriePermissionEvaluator have zero
    production consumers and OtOpcUaNodeManager never references them, yet
    ClusterAcls.razor authors NodeAcl rows and ConfigComposer.cs:51 ships them
    in every artifact. An authored deny rule has no effect.
  * IRediscoverable / IHostConnectivityProbe raise into the void (#518/#507);
    nothing ever writes a DriverHostStatus row.
  * DriverTypeRegistry is vestigial, so no factory passes a tier and every
    driver runs Tier A with the Tier-C protections dormant.

Also records the Calculation driver as picker-visible but unauthorable
(DriverConfigModal has no case) — the "registered but unauthorable" class
recurring after the Sql picker defect — and notes that no parity test guards
DriverConfigModal/DeviceModal, which is why it survived review.

Documentation corrections (source-verified):
  * ReadWriteOperations.md claimed "a denied read never hits the driver" via
    four types that do not exist in src/. Bannered + struck through; a security
    review reading that page would have concluded a per-node ACL gate exists.
  * CLAUDE.md: the Change Detection sentence was false (DriverHost consumes
    nothing); the mesh Phase 4 and Phase 5 live gates and the auto-down 1-vs-1
    gate had all PASSED; the ScriptedAlarmState table was already dropped.
  * driver-expansion tracking: Modbus RTU and SQL poll are merged, not
    pending — its command table would have made someone rebuild two shipped
    drivers in a fresh worktree.
  * drivers/README.md: dead DriverTypeRegistry paragraph, retired
    SystemPlatform namespace kind, missing Sql + Calculation rows, missing
    Modbus RTU-over-TCP transport.
  * TwinCAT.md/Galaxy.md promised an address-space rebuild that never happens.
  * Historian.md gained the #491 unproven-value-capture pointer.
  * IncrementalSync.md and AddressSpace.md bannered as wholesale v2-era (the
    rewrite is recorded as still owed, not done here); four v2 status docs
    bannered as historical; three wrong-name-for-a-live-type fixes.

Left deliberately untouched: the secrets NoOpSecretReplicator line, which
makes a security claim and needs the real behaviour identified rather than a
rename.
2026-07-27 17:26:20 -04:00

91 lines
18 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and the two v3 OPC UA namespaces (Raw + UNS — see `V3NodeIds` / `AddressSpaceRealm`). Drivers plug in through **capability interfaces** defined in `src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
- `IReadable` / `IWritable` — one-shot reads and writes
- `ITagDiscovery` — address-space enumeration
- `ISubscribable` — driver-pushed data-change streams
- `IHostConnectivityProbe` — per-host reachability events
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
- `IAlarmSource` — driver-emitted OPC UA A&C events
- `IHistoryProvider` — driver-side raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md))
- `IRediscoverable` — driver-initiated address-space rebuild notifications
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-side `IHistoryProvider` HistoryRead path
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver **factories** are registered at startup in `DriverFactoryRegistry` (`src/Core/ZB.MOM.WW.OtOpcUa.Core/Hosting/DriverFactoryRegistry.cs`) — all 12 in one place, `src/Server/ZB.MOM.WW.OtOpcUa.Host/Drivers/DriverFactoryBootstrap.cs:147-164`. Type names are the `DriverTypeNames` constants (`src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeNames.cs`), guarded bidirectionally by `DriverTypeNamesGuardTests`.
> ⚠️ **`DriverTypeRegistry` / `DriverTypeMetadata` are vestigial.** No production code constructs or reads them — the class is referenced only by its own unit tests. Its `AllowedNamespaceKinds` field was retired along with the v3 `Namespace` entity (`DriverTypeRegistry.cs:97`), and the `SystemPlatform` namespace kind no longer exists.
>
> **Stability tier** likewise does not come from that registry: it is the `DriverTier tier = DriverTier.A` parameter on `DriverFactoryRegistry.cs:46`, and **no factory in `src/Drivers/` passes a tier**, so every shipped driver runs Tier A. The Tier-C-only protections described in [docs/v2/driver-stability.md](../v2/driver-stability.md) — `MemoryRecycle` hard-breach kill (`MemoryRecycle.cs:54`) and `ScheduledRecycleScheduler` (`:43`) — are therefore dormant for every driver.
## Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|--------|--------------|:----:|----------------|--------------|---------------|
| [Galaxy](Galaxy.md) | `Driver.Galaxy` (+ `.Browser`, `.Contracts`) | A | gRPC to the external `mxaccessgw` gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process `Galaxy.{Shared, Host, Proxy}` + named-pipe Windows service. Native MxAccess alarms work end-to-end |
| [Modbus TCP / RTU-over-TCP](Modbus.md) | `Driver.Modbus` (+ `.Addressing`, `.Contracts`) | A | NModbus-derived in-house client; `Transport` selects MBAP (TCP) or RTU CRC-16 framing over a socket | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver. `Transport=RtuOverTcp` (`ModbusTransportMode`, default `Tcp`) targets serial→Ethernet gateways via `ModbusRtuOverTcpTransport` + `ModbusRtuFraming` + `ModbusCrc`, with `ModbusTransportDesyncException` carrying distinct CrcMismatch/UnitMismatch reasons; **direct-serial transport is descoped**. Merged `0f38f486` (#495) |
| [Siemens S7](S7.md) | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| [AB CIP](AbCip.md) | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| [AB Legacy](AbLegacy.md) | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
| [TwinCAT](TwinCAT.md) | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
| [FOCAS](FOCAS.md) | `Driver.FOCAS` | A | Pure-managed `FocasWireClient` — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | `IWritable` is implemented but read-only by design — `WriteAsync` returns `BadNotWritable` for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side `IHistoryProvider` (forwards HistoryRead to the upstream server). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
| [MQTT](Mqtt.md) | `Driver.Mqtt` (+ `.Browser`, `.Contracts`) | A | [MQTTnet 5](https://github.com/dotnet/MQTTnet) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | **Push, not poll, and read-only** — the broker delivers PUBLISH frames the driver forwards straight to `ISubscribable.OnDataChange`; `IReadable` serves the last retained/received value from cache, and there is **no `IWritable`** (nothing publishes back). Subscriptions are indexed **by topic filter, not by topic**, so wildcard tags survive a reconnect. A rejected CONNACK throws `MqttConnectRejectedException`: unrecoverable codes → `Faulted` + supervisor stop, transient → retry. **Two modes:** `Plain` binds a tag to a concrete topic + JSON path; `SparkplugB` decodes vendored Eclipse-Tahu protobuf under one `spBv1.0/{groupId}/#` subscription and binds by the `group/edgeNode/device?/metric` tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). `IRediscoverable` fires on a DBIRTH but is **inert platform-side** — see [#507](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/507) |
| [MTConnect](MTConnect.md) | `Driver.MTConnect` (+ `.Contracts`) | — | Hand-rolled `System.Xml.Linq` HTTP/XML client against a vendor-neutral MTConnect Agent (`/probe`, `/current`, `/sample`) — no TrakHound dependency (dropped; see the driver doc) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Read-only by design (no `IWritable`). Production data plane is entirely `ISubscribable`/`OnDataChange``IReadable` is CLI/test-only. Browse is free via the Wave-0 universal discovery browser, no bespoke browser project. `IRediscoverable`/`IHostConnectivityProbe` have no server-side consumer yet — a pre-existing fleet-wide gap, not MTConnect-specific |
| **Sql** (no dedicated page — see [design](../plans/2026-07-15-sql-poll-driver-design.md)) | `Driver.Sql` (+ `.Browser`, `.Contracts`) | A | `Microsoft.Data.SqlClient` behind an `ISqlDialect` seam (`SqlServerDialect` shipped; Postgres/ODBC deferred) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe | Read-only DB-poll driver with a bespoke schema browser. **Credentials are never persisted** — the deploy gate rejects a stored `connectionString` (#498) and catalog identifiers are validated against the live catalog's own spelling (#496). `SupportsOnlineDiscovery => false` by design (the bespoke browser wins). `SqlTagModel.Query` is deferred to P3 and rejected end-to-end by parser, validator, planner and editor. Merged `4ad54037` |
| **Calculation** (see [Raw.md](../Raw.md#the-calculation-driver)) | `Driver.Calculation` | A | none — computes from other tags' RawPaths | IDriver, IDependencyConsumer, ISubscribable, IReadable | **Pseudo-driver**, not a wire protocol: signal-level tags computed from other tags via a script, with deploy-time `scriptId`-existence + Tarjan cycle gates. Its probe is parse-only (no backend to reach). ⚠️ **No typed config form**`DriverConfigModal` has no `Calculation` case, so `RunTimeout` is currently unauthorable through the AdminUI |
| [Historian.Gateway](../Historian.md) | `Driver.Historian.Gateway` | — | `ZB.MOM.WW.HistorianGateway.Client` gRPC (`historian_gateway.v1`) | IHistorianDataSource (server-side read backend) + alarm `SendEvent` writer + `WriteLiveValues` recorder + `IHistorianProvisioning` | Not a tag driver — the sole historian backend. Registers `GatewayHistorianDataSource : IHistorianDataSource` for HistoryRead and serves alarm-write + continuous historization through the gateway. No `IDriver`/`ITagDiscovery` surface. (The retired Wonderware sidecar backend it replaced is documented at [Historian.Wonderware.md](Historian.Wonderware.md).) |
## Per-driver documentation
- **Galaxy** has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- [Galaxy.md](Galaxy.md) — gateway gRPC bridge, hierarchy source, runtime probes
- [Galaxy-Repository.md](../v1/drivers/Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection (v1 archive)
- **FOCAS** has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
- [FOCAS.md](FOCAS.md) — deployment, config, capability surface, alarm projection, troubleshooting
- **Modbus TCP**, **AB CIP**, **AB Legacy**, **Siemens S7**, **TwinCAT**, **OPC UA Client**, and **MQTT** each have a per-driver overview page:
- [Modbus.md](Modbus.md) — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
- [AbCip.md](AbCip.md) — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
- [AbLegacy.md](AbLegacy.md) — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
- [S7.md](S7.md) — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
- [TwinCAT.md](TwinCAT.md) — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
- [Mqtt.md](Mqtt.md) — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding, `#`-observation browser, CONNACK-rejection semantics, **Sparkplug B** (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the **Known gaps** table
- **MTConnect** has a short getting-started doc because the hand-rolled-vs-TrakHound divergence, the
data-plane precedence rules, and a non-trivial known-limitations list need explaining up front:
- [MTConnect.md](MTConnect.md) — Agent config, `FullName`==DataItem `id`, `UNAVAILABLE``BadNoCommunication`, CONDITION-as-`String`, browse-via-universal-browser, fixture recipe, deferred write-back
- **Historian.Gateway** (server-side historian backend, not a tag driver) is documented in the main guide:
- [../Historian.md](../Historian.md) — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (`SendEvent`), continuous historization (`WriteLiveValues`), `EnsureTags` provisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: [Historian.Wonderware.md](Historian.Wonderware.md).)
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path; that file is the authoritative per-driver reference.
## Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
- [AB Legacy](AbLegacy-Test-Fixture.md) — Dockerized `ab_server` PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. `/1,0` cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (`B3:0/5`) still surface BadState — real HW / RSEmulate 500 for those
- [TwinCAT](TwinCAT-Test-Fixture.md) — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via `FakeTwinCATClient` with native-notification harness
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — Dockerized `opc-plc` integration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mocked `Session`
- [MQTT](Mqtt-Test-Fixture.md) — Dockerized `eclipse-mosquitto` with **TLS + real auth on both listeners (no anonymous fallback)** + a JSON-publisher sidecar; env-gated live suite (**15 tests**) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a **project-owned C# edge-node simulator** on the `sparkplug` compose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, so `docker restart otopcua-sparkplug-sim` is how you force a fresh one
- [Galaxy](../v1/drivers/Galaxy-Test-Fixture.md) — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
- [MTConnect](../../tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.MTConnect.IntegrationTests/Docker/README.md) — Dockerized `mtconnect/agent` + stdlib SHDR adapter (two services, the Agent alone reports everything `UNAVAILABLE`); 12/12 against the real Agent, canned XML unit fixtures cover the bulk (491/491)
## Related cross-driver docs
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.