- Driver.FOCAS.Cli-001: WriteCommand.ParseValue now wraps numeric FormatException / OverflowException as CliFx CommandException with the offending value. - Driver.FOCAS.Cli-002: SubscribeCommand's OnDataChange handler and the banner both take a writeLock so notification-callback and main-thread writes can't interleave; handler exceptions are warn-and-swallow. - Driver.FOCAS.Cli-003: FocasCommandBase.ValidateOptions rejects --cnc-port outside 1..65535, non-positive --timeout-ms, and non-positive --interval-ms; ExecuteAsync calls it first. - Driver.FOCAS.Cli-004: 'await using var driver' is the sole driver disposal path; dropped the redundant explicit await ShutdownAsync. - Driver.FOCAS.Cli-005 (Deferred): the fix lives in Driver.Cli.Common.SnapshotFormatter — explicitly naming the status-code shortlist there benefits every driver CLI. Left as a Driver.Cli.Common follow-up. - Registered the new tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Tests project in ZB.MOM.WW.OtOpcUa.slnx. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
80 lines
3.0 KiB
C#
80 lines
3.0 KiB
C#
using CliFx.Attributes;
|
|
using CliFx.Infrastructure;
|
|
using Shouldly;
|
|
using Xunit;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Tests;
|
|
|
|
/// <summary>
|
|
/// Driver.FOCAS.Cli-003: numeric options that are not range-checked at the CLI
|
|
/// boundary surface either as opaque downstream exceptions or as tight-spinning
|
|
/// poll loops rather than a clear "value must be positive" message. These tests
|
|
/// pin the validation contract for <c>--cnc-port</c>, <c>--timeout-ms</c>, and
|
|
/// <c>--interval-ms</c>.
|
|
/// </summary>
|
|
[Trait("Category", "Unit")]
|
|
public sealed class FocasCommandBaseValidationTests
|
|
{
|
|
// Test-only FocasCommandBase concrete subclass that exposes the protected ValidateOptions
|
|
// helper. The [Command] attribute is required by the CliFx analyzer
|
|
// (CliFx_CommandMustBeAnnotated) — this command is never registered with the CLI app
|
|
// but the analyzer rule fires for every ICommand implementor in the compilation.
|
|
[Command("noop-test", Description = "Test-only probe of FocasCommandBase.ValidateOptions.")]
|
|
private sealed class Probe : FocasCommandBase
|
|
{
|
|
public int IntervalMs { get; init; }
|
|
|
|
public override ValueTask ExecuteAsync(IConsole console) => default;
|
|
|
|
public void InvokeValidate() => ValidateOptions(IntervalMs);
|
|
public void InvokeValidateNoInterval() => ValidateOptions(intervalMs: null);
|
|
}
|
|
|
|
[Fact]
|
|
public void Validate_accepts_default_options()
|
|
{
|
|
var sut = new Probe { CncHost = "host", IntervalMs = 1000 };
|
|
Should.NotThrow(() => sut.InvokeValidate());
|
|
}
|
|
|
|
[Theory]
|
|
[InlineData(0)]
|
|
[InlineData(-1)]
|
|
[InlineData(65536)]
|
|
public void Validate_rejects_out_of_range_cnc_port(int port)
|
|
{
|
|
var sut = new Probe { CncHost = "host", CncPort = port, IntervalMs = 1000 };
|
|
var ex = Should.Throw<CliFx.Exceptions.CommandException>(() => sut.InvokeValidate());
|
|
ex.Message.ShouldContain("cnc-port", Case.Insensitive);
|
|
}
|
|
|
|
[Theory]
|
|
[InlineData(0)]
|
|
[InlineData(-100)]
|
|
public void Validate_rejects_non_positive_timeout_ms(int timeoutMs)
|
|
{
|
|
var sut = new Probe { CncHost = "host", TimeoutMs = timeoutMs, IntervalMs = 1000 };
|
|
var ex = Should.Throw<CliFx.Exceptions.CommandException>(() => sut.InvokeValidate());
|
|
ex.Message.ShouldContain("timeout-ms", Case.Insensitive);
|
|
}
|
|
|
|
[Theory]
|
|
[InlineData(0)]
|
|
[InlineData(-500)]
|
|
public void Validate_rejects_non_positive_interval_ms(int intervalMs)
|
|
{
|
|
var sut = new Probe { CncHost = "host", IntervalMs = intervalMs };
|
|
var ex = Should.Throw<CliFx.Exceptions.CommandException>(() => sut.InvokeValidate());
|
|
ex.Message.ShouldContain("interval-ms", Case.Insensitive);
|
|
}
|
|
|
|
[Fact]
|
|
public void Validate_skips_interval_check_when_command_omits_it()
|
|
{
|
|
// probe / read / write don't take an --interval-ms option; the validator must
|
|
// skip that check when the caller passes null.
|
|
var sut = new Probe { CncHost = "host" };
|
|
Should.NotThrow(() => sut.InvokeValidateNoInterval());
|
|
}
|
|
}
|