Booted the server against the Modbus seed end-to-end to exercise the factory wiring shipped in #216 + #217. Surfaced two real issues with the seeds themselves; fixed both: 1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster` enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`. All four seed scripts now insert the binding row alongside the ClusterNode row. Without this, the server fails bootstrap with `BootstrapException: Central DB unreachable and no local cache available` (the Unauthorized error gets swallowed on top of the HTTP fallback path). 2. **Config cache gitignore.** Running the server from the repo root writes `config_cache.db` + `config_cache-log.db` next to the cwd, outside the existing `src/.../Server/config_cache.db` pattern. Add a `config_cache*.db` pattern so any future run location is covered. ## Verified live against Modbus Booted server against `seed-modbus-smoke.sql` → pymodbus standard fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`: === Modbus e2e summary: 4/5 passed === [PASS] Probe [PASS] Driver loopback [PASS] Server bridge (driver → server → client) [FAIL] OPC UA write bridge (0x801F0000) [PASS] Subscribe sees change The forward direction + subscription delivery are proven working through the server. The reverse-write failure is a seed-or-ACL issue — server log shows no exception on the write path, so the client-side status is coming from the stack's type/ACL guards. Tracking as a follow-up issue so the remaining three factory wirings can be smoke-booted against the same pattern. Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe` processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports 4840 + 4841 on this dev box; kill them first or bump the seed's DashboardPort. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
5.3 KiB
5.3 KiB