Joseph Doherty 6609141493 Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility. Every driver integration simulator now has a pinned Docker image alongside the existing native launcher — Docker is the primary path, native fallbacks kept for contributors who prefer them. Matches the already-Dockerized OpcUaClient/opc-plc pattern from #215 so every fixture in the fleet presents the same compose-up/test/compose-down loop. Reproducibility gain: what used to require a local pip/Python install (Modbus pymodbus, S7 python-snap7) or a per-OS C build from source (AB CIP ab_server from libplctag) now collapses to a Dockerfile + docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 12:09:44 -04:00

60 lines
7.9 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through **capability interfaces** defined in `src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
- `IReadable` / `IWritable` — one-shot reads and writes
- `ITagDiscovery` — address-space enumeration
- `ISubscribable` — driver-pushed data-change streams
- `IHostConnectivityProbe` — per-host reachability events
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
- `IAlarmSource` — driver-emitted OPC UA A&C events
- `IHistoryProvider` — raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../HistoricalDataAccess.md))
- `IRediscoverable` — driver-initiated address-space rebuild notifications
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver type metadata is registered at startup in `DriverTypeRegistry` (`src/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs`). The registry records each type's allowed namespace kinds (`Equipment` / `SystemPlatform` / `Simulated`), its JSON Schema for `DriverConfig` / `DeviceConfig` / `TagConfig` columns, and its stability tier per [docs/v2/driver-stability.md](../v2/driver-stability.md).
## Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|--------|--------------|:----:|----------------|--------------|---------------|
| [Galaxy](Galaxy.md) | `Driver.Galaxy.{Shared, Host, Proxy}` | C | MXAccess COM + `aahClientManaged` + SqlClient | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe | Out-of-process — Host is its own Windows service (.NET 4.8 x86 for the COM bitness constraint); Proxy talks to Host over a named pipe |
| Modbus TCP | `Driver.Modbus` | A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver |
| Siemens S7 | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| AB CIP | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| AB Legacy | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
| TwinCAT | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
| FOCAS | `Driver.FOCAS` | C | FANUC FOCAS2 (`Fwlib32.dll` P/Invoke) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Tier C — FOCAS DLL has crash modes that warrant process isolation. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map |
| OPC UA Client | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver. Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
## Per-driver documentation
- **Galaxy** has its own docs in this folder because the out-of-process architecture + MXAccess COM rules + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- [Galaxy.md](Galaxy.md) — COM bridge, STA pump, IPC, runtime probes
- [Galaxy-Repository.md](Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection
- **All other drivers** share a single per-driver specification in [docs/v2/driver-specs.md](../v2/driver-specs.md) — addressing, data-type maps, connection settings, and quirks live there. That file is the authoritative per-driver reference; this index points at it rather than duplicating.
## Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
- [AB Legacy](AbLegacy-Test-Fixture.md) — no integration fixture, unit-only via `FakeAbLegacyTag` (libplctag PCCC)
- [TwinCAT](TwinCAT-Test-Fixture.md) — no integration fixture, unit-only via `FakeTwinCATClient` with native-notification harness
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — no integration fixture, unit-only via mocked `Session`; loopback against this repo's own server is the obvious next step
- [Galaxy](Galaxy-Test-Fixture.md) — richest harness: E2E Host subprocess + ZB SQL live-smoke + MXAccess opt-in
## Related cross-driver docs
- [HistoricalDataAccess.md](../HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The Galaxy driver's Aveva Historian implementation is the first; OPC UA Client forwards to the upstream server; other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering.
- [Subscriptions.md](../Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.