This website requires JavaScript.
Explore
Help
Register
Sign In
dohertj2
/
lmxopcua
Watch
1
Star
0
Fork
0
You've already forked lmxopcua
Code
Issues
Pull Requests
Actions
Packages
Projects
Releases
Wiki
Activity
Files
65de2b4a09809efdccbb7a7a7126fabcd1533b2f
lmxopcua
/
tests
/
ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests
/
ModbusDriverTests.cs
Joseph Doherty
058c3dddd3
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
...
Co-Authored-By: Claude Opus 4.7 (1M context) <
noreply@anthropic.com
>
2026-04-18 11:55:21 -04:00
10 KiB
Raw
Blame
History
View Raw
Reference in New Issue
View Git Blame
Copy Permalink