Lifts the previous "one driver = one slave" assumption so a single Modbus driver instance can front N RTU slaves behind one Ethernet gateway (Anybus, ProSoft, Lantronix style). Each tag carries an optional UnitId that drives the MBAP unit-id byte per-PDU, and the IPerCallHostResolver contract surfaces per-slave host strings so per-PLC circuit breakers fire per-slave (matches the AB CIP template documented in docs/v2/multi-host-dispatch.md). Changes: - ModbusTagDefinition gains optional UnitId (byte?). Null = use driver-level ModbusDriverOptions.UnitId (preserves single-slave deployments verbatim). - ResolveUnitId(tag) helper computed once per ReadOneAsync / WriteOneAsync call; passed through ReadRegisterBlockAsync / ReadBitBlockAsync / ReadRegisterBlockChunkedAsync / ReadBitBlockChunkedAsync explicitly. The probe loop continues using driver-level UnitId (the probe is a connection-health check, not slave-specific). - ModbusDriver implements IPerCallHostResolver. ResolveHost(fullReference) returns "host:port/unitN" — distinct strings per slave so the resilience pipeline keys breakers on the right granularity. Unknown references fall back to the bare HostName (single-slave behaviour). - BitInRegister RMW path also threads the per-tag UnitId through both the read and write halves so a multi-slave deployment stays correct under bit- level writes. - Factory DTO + JSON binding extended with the per-tag UnitId field. Tests (4 new ModbusMultiUnitTests): - Per-tag UnitId routes to the correct slave in the MBAP header (driver-level UnitId=99 must NOT appear when both tags override). - Tag without override falls back to driver-level UnitId. - IPerCallHostResolver returns distinct "host:port/unitN" strings per slave. - Unknown reference returns the bare HostName fallback. Existing 220 unit tests + 107 addressing tests still green. Per-PLC breaker isolation under simulated dead slaves is verifiable via the existing AB CIP test infra; live coverage lands as an integration test in the #138 docs/e2e refresh.
4.5 KiB
4.5 KiB