Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
..
DL205
Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation. Before this PR every server-side Modbus exception AND every transport-layer failure collapsed to BadInternalError (0x80020000) in the driver's Read/Write results, making field diagnosis 'is this a tag misconfig or a driver bug?' impossible from the OPC UA client side. PR 52 adds a MapModbusExceptionToStatus helper that translates per spec: 01 Illegal Function -> BadNotSupported (0x803D0000); 02 Illegal Data Address -> BadOutOfRange (0x803C0000); 03 Illegal Data Value -> BadOutOfRange; 04 Server Failure -> BadDeviceFailure (0x80550000); 05/06 Acknowledge/Busy -> BadDeviceFailure; 0A/0B Gateway -> BadCommunicationError (0x80050000); unknown -> BadInternalError fallback. Non-Modbus failures (socket drop, timeout, malformed frame) in ReadAsync are now distinguished from tag-level faults: they map to BadCommunicationError so operators check network/PLC reachability rather than tag definitions. Why per-DL205: docs/v2/dl205.md documents DL205/DL260 returning only codes 01-04 with specific triggers -- exception 04 specifically means 'CPU in PROGRAM mode during a protected write', which is operator-recoverable by switching the CPU to RUN; surfacing it as BadDeviceFailure (not BadInternalError) makes the fix obvious. Changes in ModbusDriver: Read catch-chain now ModbusException first (-> mapper), generic Exception second (-> BadCommunicationError); Write catch-chain same pattern but generic Exception stays BadInternalError because write failures can legitimately come from EncodeRegister (out-of-range value) which is a driver-layer fault. Unit tests: MapModbusExceptionToStatus theory exercising every code in the table including the 0xFF fallback; Read_surface_exception_02_as_BadOutOfRange with an ExceptionRaisingTransport that forces code 02; Write_surface_exception_04_as_BadDeviceFailure for CPU-mode faults; Read_non_modbus_failure_maps_to_BadCommunicationError with a NonModbusFailureTransport that raises EndOfStreamException. 115/115 Modbus.Tests pass. Integration test: DL205ExceptionCodeTests.DL205_FC03_at_unmapped_register_returns_BadOutOfRange reads HR[16383] which is beyond the seeded uint16 cells on the dl205.json profile; pymodbus returns exception 02 and the driver surfaces BadOutOfRange. 11/11 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 22:28:37 -04:00
Mitsubishi
Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
Pymodbus
Phase 3 PR 58 -- Mitsubishi MELSEC pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/mitsubishi.json modelling a representative MELSEC Modbus Device Assignment block: D0..D1023 -> HR[0..1023], M-relay marker at coil 512 (cell 32) and X-input marker at DI 528 (cell 33). Covers the canonical MELSEC quirks from docs/v2/mitsubishi.md: D0 fingerprint at HR[0]=0x1234 so clients can verify the assignment parameter block is in effect, scratch HR 200..209 mirroring dl205/s7_1500/standard scratch range for uniform smoke tests, Float32 1.5f at HR[100..101] in CDAB word order (HR[100]=0, HR[101]=0x3FC0) -- same as DL260, OPPOSITE of S7 ABCD, confirms MELSEC-family driver profile default must be ByteOrder.WordSwap. Int32 0x12345678 CDAB at HR[300..301]. D10 = binary 1234 (0x04D2) proves MELSEC is BINARY-by-default (opposite of DL205 BCD-by-default quirk) -- reading D10 with Bcd16 data type would throw InvalidDataException on nibble 0xD. M-relay marker cell moved to address 32 (coil 512) to avoid shared-block collision with D0 uint16 marker at cell 0; pymodbus shared-blocks=true semantics allow only one type per cell index, so Modbus-coil-0 can't coexist with Modbus-HR-0 on the same sim. Same pattern we applied to dl205 profile (X-input bank at cell 1, not cell 0, to coexist with V0 marker). Adds Mitsubishi/ test directory with MitsubishiProfile.cs (SmokeHoldingRegister=200, SmokeHoldingValue=7890, BuildOptions with probe-disabled + 2s timeout) and MitsubishiSmokeTests.cs (Mitsubishi_roundtrip_write_then_read_of_holding_register single fact that writes 7890 at HR[200] then reads back, gated on MODBUS_SIM_PROFILE=mitsubishi). csproj copies Mitsubishi/** as PreserveNewest. Per-model differences (FX5U firmware gate, QJ71MT91 FC22/23 absence, FX/iQ-F octal vs Q/L/iQ-R hex X-addressing) are handled in the MelsecAddress helper (PR 59) + per-model test classes (PR 60). Verified: smoke 1/1 passes against live mitsubishi sim. Prior S7 tests 4/4 still green when swapped back. Modbus.Tests unit suite 143/143.
2026-04-18 23:02:29 -04:00
S7
Phase 3 PR 57 -- S7 byte-order + fingerprint integration tests against s7_1500 pymodbus profile. Three facts in new S7_ByteOrderTests class: (1) S7_Float32_ABCD_decodes_1_5f_from_HR100 reads HR[100..101] with ModbusByteOrder.BigEndian AND with WordSwap on the same wire bytes; asserts BigEndian==1.5f AND WordSwap!=1.5f -- proving both that Siemens S7 stores Float32 in ABCD word order (opposite of DL260 CDAB) and that the ByteOrder flag is not a no-op on the same wire buffer. (2) S7_Int32_ABCD_decodes_0x12345678_from_HR300 reads HR[300]=0x1234 + HR[301]=0x5678 with BigEndian and asserts the reassembled Int32 = 0x12345678; documents the contrast with DL260 CDAB Int32 encoding. (3) S7_DB1_fingerprint_marker_at_HR0_reads_0xABCD reads HR[0]=0xABCD -- real MB_SERVER deployments reserve DB1.DBW0 as a fingerprint so clients can verify they're pointing at the right DB, protecting against typos in the MB_SERVER.MB_HOLD_REG.DB_number parameter. No driver code changes -- the ByteOrder.BigEndian path has existed since PR 24; this PR exists to lock in the S7-specific semantics at the integration level so future refactors of NormalizeWordOrder can't silently break S7. All 3 tests gate on MODBUS_SIM_PROFILE=s7_1500 so they skip cleanly against dl205 or standard profiles. Verified end-to-end: 4/4 S7 integration tests pass (1 smoke from PR 56 + 3 new). No regression in driver unit tests. Per the per-quirk-PR plan: the S7 quirks NOT testable via pymodbus sim (MB_SERVER STATUS 0x8383 optimized-DB behavior, port-per-connection semantics, CP 343-1 Lean license rejection, STOP-mode non-determinism) remain in docs/v2/s7.md as design guidance for driver users rather than automated tests -- they're TIA-Portal-side or CP-hardware-side behaviors that pymodbus cannot reproduce without custom Python actions.
2026-04-18 22:58:44 -04:00
ModbusSimulatorFixture.cs
Phase 3 PR 43 — followup commit: validate pymodbus simulator end-to-end + fix three real bugs surfaced by running it. winget-installed Python 3.12.10 + pip-installed pymodbus[simulator]==3.13.0 on the dev box; both profiles boot cleanly, the integration-suite smoke test passes against either profile.
2026-04-18 21:14:02 -04:00
ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.csproj
Phase 3 PR 58 -- Mitsubishi MELSEC pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/mitsubishi.json modelling a representative MELSEC Modbus Device Assignment block: D0..D1023 -> HR[0..1023], M-relay marker at coil 512 (cell 32) and X-input marker at DI 528 (cell 33). Covers the canonical MELSEC quirks from docs/v2/mitsubishi.md: D0 fingerprint at HR[0]=0x1234 so clients can verify the assignment parameter block is in effect, scratch HR 200..209 mirroring dl205/s7_1500/standard scratch range for uniform smoke tests, Float32 1.5f at HR[100..101] in CDAB word order (HR[100]=0, HR[101]=0x3FC0) -- same as DL260, OPPOSITE of S7 ABCD, confirms MELSEC-family driver profile default must be ByteOrder.WordSwap. Int32 0x12345678 CDAB at HR[300..301]. D10 = binary 1234 (0x04D2) proves MELSEC is BINARY-by-default (opposite of DL205 BCD-by-default quirk) -- reading D10 with Bcd16 data type would throw InvalidDataException on nibble 0xD. M-relay marker cell moved to address 32 (coil 512) to avoid shared-block collision with D0 uint16 marker at cell 0; pymodbus shared-blocks=true semantics allow only one type per cell index, so Modbus-coil-0 can't coexist with Modbus-HR-0 on the same sim. Same pattern we applied to dl205 profile (X-input bank at cell 1, not cell 0, to coexist with V0 marker). Adds Mitsubishi/ test directory with MitsubishiProfile.cs (SmokeHoldingRegister=200, SmokeHoldingValue=7890, BuildOptions with probe-disabled + 2s timeout) and MitsubishiSmokeTests.cs (Mitsubishi_roundtrip_write_then_read_of_holding_register single fact that writes 7890 at HR[200] then reads back, gated on MODBUS_SIM_PROFILE=mitsubishi). csproj copies Mitsubishi/** as PreserveNewest. Per-model differences (FX5U firmware gate, QJ71MT91 FC22/23 absence, FX/iQ-F octal vs Q/L/iQ-R hex X-addressing) are handled in the MelsecAddress helper (PR 59) + per-model test classes (PR 60). Verified: smoke 1/1 passes against live mitsubishi sim. Prior S7 tests 4/4 still green when swapped back. Modbus.Tests unit suite 143/143.
2026-04-18 23:02:29 -04:00