Joseph Doherty 394d126b2e Phase 3 PR 64 -- S7 IReadable + IWritable via S7.Net string-based Plc.ReadAsync/WriteAsync. Adds IReadable + IWritable capability interfaces to S7Driver, routing reads/writes through S7netplus's string-address API (Plc.ReadAsync(string, ct) / Plc.WriteAsync(string, object, ct)). All operations serialize on the class's SemaphoreSlim Gate because S7netplus mandates one Plc connection per PLC with client-side serialization -- parallel reads against a single S7 CPU queue wire-side anyway and just eat connection-resource budget. Supported data types in this PR: Bool, Byte, Int16, UInt16, Int32, UInt32, Float32. S7.Net's string-based read returns UNSIGNED boxed values (DBX=bool, DBB=byte, DBW=ushort, DBD=uint); the driver reinterprets them into the requested S7DataType via the (DataType, Size, raw) switch: unchecked short-cast for Int16, unchecked int-cast for Int32, BitConverter.UInt32BitsToSingle for Float32. Writes inverse the conversion -- Int16 -> unchecked ushort cast, Int32 -> unchecked uint cast, Float32 -> BitConverter.SingleToUInt32Bits -- before handing to S7.Net's WriteAsync. This avoids a second PLC round-trip that a typed ReadAsync(DataType, db, offset, VarType, ...) overload would need. Int64, UInt64, Float64, String, DateTime throw NotSupportedException (-> BadNotSupported StatusCode); S7 STRING has non-trivial header semantics + LReal/DateTime need typed S7.Net API paths, both land in a follow-up PR when scope demands. InitializeAsync now parses every tag's Address string via S7AddressParser at init time. Bad addresses throw FormatException and flip health to Faulted -- callers can't register a broken driver. The parsed form goes into _parsedByName so Read/Write can consult Size/BitOffset without re-parsing per operation. StatusCode mapping in catch chain: unknown tag name -> BadNodeIdUnknown (0x80340000), unsupported data type -> BadNotSupported (0x803D0000), read-only tag write attempt -> BadNotWritable (0x803B0000), S7.Net PlcException (carries PUT/GET-disabled signal on S7-1200/1500) -> BadDeviceFailure (0x80550000) so operators see a TIA-Portal config problem rather than a transient-fault false flag per driver-specs.md \u00A75, any other runtime exception on read -> BadCommunicationError (0x80050000) to distinguish socket/timeout from tag-level faults. Write generic-exception path stays BadInternalError because write failures can legitimately be driver-side value-range problems. Unit tests (S7DriverReadWriteTests, 3 facts): Initialize_rejects_invalid_tag_address_and_fails_fast -- Tags with a malformed address must throw at InitializeAsync rather than producing a half-healthy driver; ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequirePlc and throw the uniform 'not initialized' message. Wire-level round-trip coverage (integration test against a live S7-1500 or a mock S7 server) is deferred -- S7.Net doesn't ship an in-process fake and a conformant mock is non-trivial. 53/53 Modbus.Driver.S7.Tests pass (50 parser + 3 read/write). dotnet build clean.
2026-04-19 00:10:41 -04:00
..
Phase 3 PR 28 — Admin UI cert-trust management page. New /certificates route (FleetAdmin-only) surfaces the OPC UA server's PKI store rejected + trusted certs and gives operators Trust / Delete / Revoke actions so rejected client certs can be promoted without touching disk. CertTrustService reads $PkiStoreRoot/{rejected,trusted}/certs/*.der files directly via X509CertificateLoader — no Opc.Ua dependency in the Admin project, which keeps the Admin host runnable on a machine that doesn't have the full Server install locally (only needs the shared PKI directory reachable; typical deployment has Admin + Server side-by-side on the same box and PkiStoreRoot defaults match so a plain-vanilla install needs no override). CertTrustOptions bound from the Admin's 'CertTrust:PkiStoreRoot' section, default %ProgramData%\OtOpcUa\pki (matches OpcUaServerOptions.PkiStoreRoot default). Trust action moves the .der from rejected/certs/ to trusted/certs/ via File.Move(overwrite:true) — idempotent, tolerates a concurrent operator doing the same move. Delete wipes the file. Revoke removes from trusted/certs/ (Opc.Ua re-reads the Directory store on each new client handshake, so no explicit reload signal is needed; operators retry the rejected connection after trusting). Thumbprint matching is case-insensitive because X509Certificate2.Thumbprint is upper-case hex but operators copy-paste from logs that sometimes lowercase it. Malformed files in the store are logged + skipped — a single bad .der can't take the whole management page offline. Missing store directories produce empty lists rather than exceptions so a pristine install (Server never run yet, no rejected/trusted dirs yet) doesn't crash the page.
2026-04-18 14:37:55 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
Phase 3 PR 59 -- MelsecAddress helper for MELSEC X/Y hex-vs-octal family trap + D/M bank bases. Adds MelsecAddress static class with XInputToDiscrete, YOutputToCoil, MRelayToCoil, DRegisterToHolding helpers and a MelsecFamily enum {Q_L_iQR, F_iQF} that drives whether X/Y addresses are parsed as hex (Q-series convention) or octal (FX-series convention). This is the #1 MELSEC driver bug source per docs/v2/mitsubishi.md: the string 'X20' on a MELSEC-Q means DI 32 (hex 0x20) while the same string on an FX3U means DI 16 (octal 0o20). The helper forces the caller to name the family explicitly; no 'sensible default' because wrong defaults just move the bug. Key design decisions: (1) Family is an enum argument, not a helper-level static-selector, because real deployments have BOTH Q-series and FX-series PLCs on the same gateway -- one driver instance per device means family must be per-tag, not per-driver. (2) Bank base is a ushort argument defaulting to 0. Real QJ71MT91/LJ71MT91 assignment blocks commonly place X at DI 8192+, Y at coil 8192+, etc. to leave the low-address range for D-registers; the helper takes the site's configured base as runtime config rather than a compile-time constant. Matches the 'driver opt-in per tag' pattern DirectLogicAddress established for DL260. (3) M-relay and D-register are DECIMAL on every MELSEC family -- docs explicitly; the MELSEC confusion is only about X/Y, not about data registers or internal relays. Helpers reject non-numeric M/D addresses and honor bank bases the same way. (4) Parser walks digits manually for both hex and octal (instead of int.Parse with NumberStyles) so non-hex / non-octal characters give a clear ArgumentException with the offending char + family name. Prevents a subtle class of bugs where int.Parse('X20', Hex) silently returns 32 even for F_iQF callers. Unit tests (MelsecAddressTests, 34 facts): XInputToDiscrete_QLiQR_parses_hex theory (X0, X9, XA, XF, X10, X20, X1FF + lowercase); XInputToDiscrete_FiQF_parses_octal theory (X0, X7, X10, X20, X777); YOutputToCoil equivalents; Same_address_string_decodes_differently_between_families (the headline trap, X20 => 32 on Q vs 16 on FX); reject-non-octal / reject-non-hex / reject-empty / overflow facts; honors-bank-base for X and M and D. 176/176 Modbus.Tests pass (143 prior + 34 new Melsec). No driver core changes -- this is purely a new helper class in the Driver.Modbus project. PR 60 wires it into integration tests against the mitsubishi pymodbus profile.
2026-04-18 23:04:52 -04:00
Phase 3 PR 64 -- S7 IReadable + IWritable via S7.Net string-based Plc.ReadAsync/WriteAsync. Adds IReadable + IWritable capability interfaces to S7Driver, routing reads/writes through S7netplus's string-address API (Plc.ReadAsync(string, ct) / Plc.WriteAsync(string, object, ct)). All operations serialize on the class's SemaphoreSlim Gate because S7netplus mandates one Plc connection per PLC with client-side serialization -- parallel reads against a single S7 CPU queue wire-side anyway and just eat connection-resource budget. Supported data types in this PR: Bool, Byte, Int16, UInt16, Int32, UInt32, Float32. S7.Net's string-based read returns UNSIGNED boxed values (DBX=bool, DBB=byte, DBW=ushort, DBD=uint); the driver reinterprets them into the requested S7DataType via the (DataType, Size, raw) switch: unchecked short-cast for Int16, unchecked int-cast for Int32, BitConverter.UInt32BitsToSingle for Float32. Writes inverse the conversion -- Int16 -> unchecked ushort cast, Int32 -> unchecked uint cast, Float32 -> BitConverter.SingleToUInt32Bits -- before handing to S7.Net's WriteAsync. This avoids a second PLC round-trip that a typed ReadAsync(DataType, db, offset, VarType, ...) overload would need. Int64, UInt64, Float64, String, DateTime throw NotSupportedException (-> BadNotSupported StatusCode); S7 STRING has non-trivial header semantics + LReal/DateTime need typed S7.Net API paths, both land in a follow-up PR when scope demands. InitializeAsync now parses every tag's Address string via S7AddressParser at init time. Bad addresses throw FormatException and flip health to Faulted -- callers can't register a broken driver. The parsed form goes into _parsedByName so Read/Write can consult Size/BitOffset without re-parsing per operation. StatusCode mapping in catch chain: unknown tag name -> BadNodeIdUnknown (0x80340000), unsupported data type -> BadNotSupported (0x803D0000), read-only tag write attempt -> BadNotWritable (0x803B0000), S7.Net PlcException (carries PUT/GET-disabled signal on S7-1200/1500) -> BadDeviceFailure (0x80550000) so operators see a TIA-Portal config problem rather than a transient-fault false flag per driver-specs.md \u00A75, any other runtime exception on read -> BadCommunicationError (0x80050000) to distinguish socket/timeout from tag-level faults. Write generic-exception path stays BadInternalError because write failures can legitimately be driver-side value-range problems. Unit tests (S7DriverReadWriteTests, 3 facts): Initialize_rejects_invalid_tag_address_and_fails_fast -- Tags with a malformed address must throw at InitializeAsync rather than producing a half-healthy driver; ReadAsync_without_initialize_throws_InvalidOperationException + WriteAsync_without_initialize_throws_InvalidOperationException -- pre-init calls hit RequirePlc and throw the uniform 'not initialized' message. Wire-level round-trip coverage (integration test against a live S7-1500 or a mock S7 server) is deferred -- S7.Net doesn't ship an in-process fake and a conformant mock is non-trivial. 53/53 Modbus.Driver.S7.Tests pass (50 parser + 3 read/write). dotnet build clean.
2026-04-19 00:10:41 -04:00