The cross-driver README still described MQTT as pre-P2 — "Sparkplug B is P2
(`mode: SparkplugB` is a placeholder)" and "Sparkplug B has no fixture yet (P2)".
Both were false as of the P2 merge (c3a2b0f7): SparkplugB is a fully implemented
mode and the live suite is 15 tests (7 plain + 8 Sparkplug) against a
project-owned C# edge-node simulator. Mqtt.md and the scadaproj index were both
already correct; only this file missed the P2 sweep.
Filed the nine Known-gaps rows as tracking issues and linked them, so the table
stops being the only record of them:
#507 IRediscoverable is inert in v3 (platform gap — also Galaxy/TwinCAT/AbCip)
#508 write-through (IWritable) — NCMD/DCMD + plain publish
#509 a metric name containing '/' cannot be browse-committed
#510 _canRebirth captured at browse-open — reaped session still draws button
#511 Sparkplug primary-host STATE publishing (ActAsPrimaryHost)
#512 .Browser references .Driver — extract the client-options builder
#513 editor writes a meaningless payloadFormat into a Sparkplug blob
#514 Request-rebirth unarmable on a plant that birthed before the window
#515 DataSet / Template / PropertySet metric support
#507 is the one worth reading: it is a v3 platform gap, not an MQTT bug —
DriverHostActor.HandleDiscoveredNodes hard-returns, so every IRediscoverable
driver fires into a void and the edge gaining a point needs a redeploy to show up.
No code change; docs + issue links only.
14 KiB
Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (ZB.MOM.WW.OtOpcUa.Core + Core.Abstractions + Server) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through capability interfaces defined in src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/:
IDriver— lifecycle (InitializeAsync,ReinitializeAsync,ShutdownAsync,GetHealth)IReadable/IWritable— one-shot reads and writesITagDiscovery— address-space enumerationISubscribable— driver-pushed data-change streamsIHostConnectivityProbe— per-host reachability eventsIPerCallHostResolver— multi-host drivers that route each call to a target endpoint at dispatch timeIAlarmSource— driver-emitted OPC UA A&C eventsIHistoryProvider— driver-side raw / processed / at-time / events HistoryRead (see HistoricalDataAccess.md)IRediscoverable— driver-initiated address-space rebuild notificationsIHistorianDataSource— server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-sideIHistoryProviderHistoryRead path
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through CapabilityInvoker (Core/Resilience/CapabilityInvoker.cs), which wraps it in a Polly pipeline keyed on (DriverInstanceId, HostName, DriverCapability). The OTOPCUA0001 analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver type metadata is registered at startup in DriverTypeRegistry (src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs). The registry records each type's allowed namespace kinds (Equipment / SystemPlatform / Simulated), its JSON Schema for DriverConfig / DeviceConfig / TagConfig columns, and its stability tier per docs/v2/driver-stability.md.
Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|---|---|---|---|---|---|
| Galaxy | Driver.Galaxy (+ .Browser, .Contracts) |
A | gRPC to the external mxaccessgw gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process Galaxy.{Shared, Host, Proxy} + named-pipe Windows service. Native MxAccess alarms work end-to-end |
| Modbus TCP | Driver.Modbus |
A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared PollGroupEngine. DL205 PLCs are covered by AddressFormat=DL205 (octal V/X/Y/C/T/CT translation) — no separate driver |
| Siemens S7 | Driver.S7 |
A | S7netplus | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus Plc instance per PLC serialized with SemaphoreSlim — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| AB CIP | Driver.AbCip |
A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the @tags walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| AB Legacy | Driver.AbLegacy |
A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (N7:0, F8:0) — no symbol table, tag list is user-authored in the config DB |
| TwinCAT | Driver.TwinCAT |
B | Beckhoff TwinCAT.Ads (TcAdsClient) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers ValueChangedCallback events the driver forwards straight to ISubscribable.OnDataChange without polling. Symbol tree uploaded via SymbolLoaderFactory |
| FOCAS | Driver.FOCAS |
A | Pure-managed FocasWireClient — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | IWritable is implemented but read-only by design — WriteAsync returns BadNotWritable for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
| OPC UA Client | Driver.OpcUaClient |
B | OPCFoundation Opc.Ua.Client |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side IHistoryProvider (forwards HistoryRead to the upstream server). Opens a single Session against a remote OPC UA server and re-exposes its address space. Owns its own ApplicationConfiguration (distinct from Client.Shared) because it's always-on with keep-alive + TransferSubscriptions across SDK reconnect, not an interactive CLI |
| MQTT | Driver.Mqtt (+ .Browser, .Contracts) |
A | MQTTnet 5 | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Push, not poll, and read-only — the broker delivers PUBLISH frames the driver forwards straight to ISubscribable.OnDataChange; IReadable serves the last retained/received value from cache, and there is no IWritable (nothing publishes back). Subscriptions are indexed by topic filter, not by topic, so wildcard tags survive a reconnect. A rejected CONNACK throws MqttConnectRejectedException: unrecoverable codes → Faulted + supervisor stop, transient → retry. Two modes: Plain binds a tag to a concrete topic + JSON path; SparkplugB decodes vendored Eclipse-Tahu protobuf under one spBv1.0/{groupId}/# subscription and binds by the group/edgeNode/device?/metric tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). IRediscoverable fires on a DBIRTH but is inert platform-side — see #507 |
| Historian.Gateway | Driver.Historian.Gateway |
— | ZB.MOM.WW.HistorianGateway.Client gRPC (historian_gateway.v1) |
IHistorianDataSource (server-side read backend) + alarm SendEvent writer + WriteLiveValues recorder + IHistorianProvisioning |
Not a tag driver — the sole historian backend. Registers GatewayHistorianDataSource : IHistorianDataSource for HistoryRead and serves alarm-write + continuous historization through the gateway. No IDriver/ITagDiscovery surface. (The retired Wonderware sidecar backend it replaced is documented at Historian.Wonderware.md.) |
Per-driver documentation
-
Galaxy has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- Galaxy.md — gateway gRPC bridge, hierarchy source, runtime probes
- Galaxy-Repository.md — ZB SQL reader,
LocalPlatformscope filter, change detection (v1 archive)
-
FOCAS has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
- FOCAS.md — deployment, config, capability surface, alarm projection, troubleshooting
-
Modbus TCP, AB CIP, AB Legacy, Siemens S7, TwinCAT, OPC UA Client, and MQTT each have a per-driver overview page:
- Modbus.md — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
- AbCip.md — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
- AbLegacy.md — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
- S7.md — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
- TwinCAT.md — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
- OpcUaClient.md — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
- Mqtt.md — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding,
#-observation browser, CONNACK-rejection semantics, Sparkplug B (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the Known gaps table
-
Historian.Gateway (server-side historian backend, not a tag driver) is documented in the main guide:
- ../Historian.md — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (
SendEvent), continuous historization (WriteLiveValues),EnsureTagsprovisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: Historian.Wonderware.md.)
- ../Historian.md — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (
-
The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in docs/v2/driver-specs.md. The overview pages above are the short path; that file is the authoritative per-driver reference.
Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- AB CIP — Dockerized
ab_server(multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only - Modbus — Dockerized
pymodbus+ per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped - Siemens S7 — Dockerized
python-snap7server; DB/MB read + write round-trip verified end-to-end on:1102 - AB Legacy — Dockerized
ab_serverPCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end./1,0cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (B3:0/5) still surface BadState — real HW / RSEmulate 500 for those - TwinCAT — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via
FakeTwinCATClientwith native-notification harness - FOCAS — no integration fixture, unit-only via
FakeFocasClient; Tier C out-of-process isolation scoped but not shipped - OPC UA Client — Dockerized
opc-plcintegration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mockedSession - MQTT — Dockerized
eclipse-mosquittowith TLS + real auth on both listeners (no anonymous fallback) + a JSON-publisher sidecar; env-gated live suite (15 tests) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a project-owned C# edge-node simulator on thesparkplugcompose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, sodocker restart otopcua-sparkplug-simis how you force a fresh one - Galaxy — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
Related cross-driver docs
- HistoricalDataAccess.md —
IHistoryProviderdispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-sideIHistoryProvider(it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backedIHistorianDataSourceinstead. Other drivers do not implement the interface and returnBadHistoryOperationUnsupported. - AlarmTracking.md —
IAlarmSourceevent model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source. - Subscriptions.md — how the Server multiplexes subscriptions onto
ISubscribable.OnDataChange. - docs/v2/driver-stability.md — tier system (A / B / C), shared
CapabilityPolicydefaults per tier × capability,MemoryTrackinghybrid formula, and process-level recycle rules. - docs/v2/plan.md — authoritative vision, architecture decisions, migration strategy.